Certified to NSF/ANSI 61.
CABINET
Manufactured of rust-resistant heavy gauge
galvanized steel. Removable service panels.
PLUMBING CONNECTIONS
3
⁄8" O.D. stainless steel tubing inlet and outlet.
ELECTRICAL CONNECTION
7
⁄8" diameter opening for conduit connection.
COOLING UNIT
Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Tank is
stainless steel.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling
temperature of evaporator/chiller storage
water. Factory set for 40°F water. Adjustable
to 50°.
FAN MOTOR
Unit bearing self-lubricating type for
maintenance-free longer life.
CONDENSER
Copper/aluminum construction with
aluminum fins.
DRAIN PLUG
Provided with drain plug with O-ring seal.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor
with lifetime lubrication and built-in overload
protection, efficient capillary sizing, large
capacity dryer-strainer, and self-lubricated fan
cools copper/aluminum condenser. System
uses R134A refrigerant. Test pressures,
highside 375 psig., lowside 150 psig.
Protected by Halsey Taylor’s Limited 5 Year
Warranty.
VENTILATION
It is important to insure proper ventilation.
A minimum of 6 inches (152mm) to the front
must be maintained, and 6 inches (152mm) to
the rear of the unit.
NOTE: Continued product improvement makes
specifications subject to change without
notice.See Halsey Taylor website for most
current spec sheet.
ELECTRICAL
Furnished with 6" leads enclosed in junction
box for direct connection to standard 115 volt,
60 Hz, single phase.
SUGGESTED SPECIFICATIONS
Shall deliver 29.5 GPH of 50°F water at 90°F
ambient and 80°F inlet water. Designed for
use where large quantity of chilled water is
required. Compressor shall be hermetically
sealed. Manufacturer shall certify unit to be
lead free as defined by the Safe Drinking
Water Act. System controlled by adjustable
thermostat. Complies with ARI Standard 1010.
SJ30 can serve 3 fountains
Locate chiller within 15 feet of fountain for
optimum performance.
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
E5 / 8-2007
MODEL SJ30-Q
LARGE REMOTE CHILLER
Model GPH Capacity Base F.L. Shipping Rated
No. Cooled to 50° F* Rate Amps Weight Watt
Ambient Air Temp
Cap. lb. Usage
70°F 80°F 90°F†100°F
SJ30-Q 33.9 31.9 29.5 27.1 29.5 14.0 118 1290
* With projector service at 1ft. from outlet and supply water at 80° F
†
UL listed and complies with ARI Standard 1010
NOTE: A service supply stop (not included) should be installed at the cooler inlet line.
Remote Chiller
Large
halseytaylor.com
JOB NAME:
ENGINEER/CONTRACTOR NAME:
APPROVAL:
DATE: