Halsey Taylor SCWT14FL-Q User Manual

This water cooler is certied to
NSF/ANSI 61.
GENERAL
Self-contained, electric refrigerated, free-standing water cooler designed to be easily accessible to able-bodied individuals. Unit is certied to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Heavy-gauge vinyl clad steel. Resistant to wear, moisture, perspiration, heat, and sunlight. Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin nish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
SIDE-MOUNTED FOUNTAIN
Stainless steel basin. Fountain has separate valve and automatic stream regulator. Waste outlet and water supply are integral with electric water cooler.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ±5° F.
STORAGE TANK
Stainless steel evaporator/storage tank for long life. Waterways are certied to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 14.0 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain strainer. Bubbler shall be two-stream, mound­building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, evaporator/tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Side fountain to be satin nish stainless steel with pushbutton actuation. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specications subject to change without notice. See Halsey Taylor website for most current spec sheet.
Standard finish is Platinum Vinyl
Optional Finishes (no extra cost)
Slate
Almond
Optional Finishes (extra cost)
All Stainless Steel
Optional Accessories (extra cost)
Glass Filler Kit
Sump Pump Kit
Vandal-Resistant Kits
Water Filter
Foot Pedal Kit
Easy-Flex™Bubblers
Back Panel (27082C)
Trap and service stop not included.
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
C18 / 1-2005
MODEL: ■SCWT14FL-Q
SCWT SERIES
Model GPH Capacity Base F.L. Shipping Rated No. Cooled to 50° F* Rate Amps Weight Watt
Ambient Air Temp
Cap. lb. Usage
70°F 80°F 90°F
100°F
SCWT14FL-Q 18.0 15.8 13.5 12.6 13.5 8.0 80 625
* With projector service and tap water at 80° F
UL listed and complies with ARI Standard 1010
With Left Fountain
Free-Standing Cooler
www.halseytaylor.com
Printed in the U.S.A.
Free-Standing Cooler With Left Fountain
(CONTINUED)
INSTALLATION
This cooler may be installed against the wall or freestanding from the wall.
For against-the-wall installation
Provide 2" x 4" wood blocking back of nished wall for securing cooler ush with nished wall. (Refer to rough-in drawing.) Install 1
1
/4" trap 51/4"
from wall face to center of trap inlet. Trap not furnished. Install
3
/8" IPS service stop to building
supply line. Union connection and service stop not furnished.
Trap and service stop not included.
OPERATING PRESSURES
Supply water-105 psi maximum
ELECTRICAL
Electrical receptacle to be installed to receive 3-wire parallel blade grounding type male plug. Cooler can now be mounted against the wall and secured to blocking with two wood screws. Be sure 1
1
/4" O.D. slip connection tube from
cooler waste to trap is in line. Connect water supply line to
3
/8" tubing inlet connection located
inside of cabinet below shelf.
For freestanding installation
A hole is provided in back of cabinet for plumbing entrance. Install 1
1
/4" IPS trap inside
cabinet. Trap not furnished. Install
3
/8" IPS
service stop to building supply line outside of cooler cabinet. Service stop not furnished. Connect water supply from building to
3
/8" tubing
inlet connection located inside of cabinet below shelf.
NOTE: Installation outdoors in an unprotected
environment is not recommended.
Instructions to mount side fountain at jobsite:
Install fountain hanger to side of cooler cabinet.
Install fountain drain line into side of cooler, holding fountain in place as guide for proper alignment.
Remove are inlet supply tting from fountain supply line, and insert into supply opening on side of cooler.
Place fountain on hanger, insert rubber gasket between drain elbow and bottom of fountain. Install drain plug and tighten securely. Connect fountain supply line to are sitting on cooler.
Insert berglass in housing under fountain and replace cover plate.
5-1/4"
133mm
SIDE VIEW
FRONT VIEW
NOTE: A service supply stop must be installed at the cooler inlet line.
1-1/4" Trap not included.