GreenSpec®Listed,
High Efficiency OVL-II
™
Series Bi-Level
MODEL OVL-II™SER-GRN-VR
This water cooler is certified to
NSF/ANSI 61-Annex G, AB 1953.
GENERAL
GreenSpec
ed, bi-level wall-mounted water cooler designed
to be easily accessible to physically challenged
and able-bodied individuals. When properly
installed, unit meets state and federal requirements as defined by the Americans with
Disabilities Act. Unit is certified to NSF/ANSI 61
and meets requirements of the Safe Drinking
Water Act. Unit provides 50° F water at 80° F
inlet water and 90° F ambient.
FOUNTAIN
Oval shape fountain, non-corrosive stainless
steel, with brushed satin finish. Contour-formed
basin with rounded corners and edges. Oval
fountain shape requires less neck extension and
bending for the wheel chair user.
WATER CONSERVATION BUBBLER
Designed to reduce water usage while still
delivering a satisfying stream. Vandal-resistant
bubbler is one-piece, chrome-plated, with
integral hood guard design to prevent
contamination from other users, airborne
deposits and tampering.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to
prevent tampering. Unit resists corrosion and
liming. A constant stream height is automatically
maintained under line pressures that vary from
20 to 105 psi.
PUSHBAR ACTUATION MECHANISM
Self-closing, semi-circular push bar can be
actuated at any point on its 180° radius.
INLET STRAINER
Easily cleaned in-line strainer screen traps
particles of 140 microns or larger before they
enter the waterway.
REFRIGERATION SYSTEM
High-Efficiency, hermetically sealed, positive
start compressor with lifetime lubrication and
built-in overload protection, efficient capillary
sizing, large capacity dryer-strainer, and selflubricated fan cools copper/aluminum
condenser. System uses R134A refrigerant.
Protected by Halsey Taylor’s Limited 5 Year
Warranty.
®
Listed, modular, electric refrigerat-
MOUNTING FRAME
Mounting frame is manufactured of corrosion
resistant, galvanized steel. Open construction
designed for ease of installation. Mounting
frame can be shipped in advance for rough-in
installation.
PANELS
Constructed of stainless steel number 300
series with satin finish. Removable lower panel
provides access to plumbing and refrigeration
system. Panels overlap wall opening
SUGGESTED SPECIFICATIONS
Shall be GreenSpec®Listed. Shall deliver 7.5
GPH of 50° F water at 90° F ambient and 80° F
inlet water. Fountain shall include pushbar
valve on front, contour-formed basin to
eliminate splashing and standing water, and
rounded corners and edges.Bubbler shall be
one-piece, lower-flow, vandal-resistant.
Cooling unit shall have a high efficiency
positive start compressor using R134A, with
pressurized counterflow cooling evaporator/
chiller. Cooler shall comply with ANSI 117:1
and ADA for visual and motion disabilities. The
manufacturer shall certify the unit to meet the
requirements of NSF/ANSI 61-Annex G, AB
1953 , and the Safe Drinking Water Act. Unit
complies with ARI Standard 1010.
NOTE: Continued product improvement
makes specifications subject to change
without notice. See Halsey Taylor website
for most current spec sheet.
1
/
.
2"
Barrier-Free Cooler
Standard finish is Stainless Steel
Optional Accessories (extra cost)
Water Filter
■
Cane Apron
■
Each OVL-II™ SER-GRN-VR consists of
3 cartons as follows:
Mounting Frame
Cooling Unit-SJ8GRN
Fountain, Panels & Misc. Parts
JOB NAME:
ENGINEER/CONTRACTOR NAME:
APPROVAL:
DATE:
OVL-II™BARRIER-FREE SERIES
Model GPH Capacity Base F.L. Shipping Rated
No. Cooled to 50° F* Rate Amps Weight Watt
70°F 80°F 90°F†100°F
OVL-II™ SER-Q 9.3 8.3 7.5 6.8 7.5 2.8 135 260
* With projector service and tap water at 80° F
For additional specification of the cooling unit, see specification sheet for Model SJ8 Remote in this catalog.
†
UL listed and complies with ARI Standard 1010
Trap and service stop not included
Ambient Air Temp
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
Cap. lb. Usage
halseytaylor.com
A38 / 7-2010
OVL-II™SER-GRN-VR
GreenSpec®Listed,
High Efficiency,
™
OVL-II
Barrier-Free
Bi-Level Cooler
(CONTINUED)
ELECTRICAL DATA
Junction box for a (3) wire 10 AMP branch
circuit. Standard 120 volt, 60 HZ, single phase.
WALL OPENING
IMPORTANT: It is necessary to create a wall
opening 37
the floor line.
MOUNTING INSTRUCTIONS
Refer to rough-in for location of plumbing and
electrical sources. The support frame is to be
installed first. The shelf for the water chiller
should be assembled to the wall frame, and
then place chiller into position. Hang upper
panel to hanger on frame. Fountains are to be
attached to panel and wall frame. Water service
lines, waste lines and electrical are assembled
as required. The bottom panel is attached last,
after a final check for leaks and correct
functions of fountains and chiller. (For details
see the installation instructions.)
Installation requires trap to be installed in
wall. Trap and service stop not included.
OPERATING PRESSURES:
Supply water - 105 psi maximum
Minimum 40 psi supply line pressure required
in special circumstances where both sides of
bilevel are in use simultaneously to ensure
adequate stream height. Use of water filter in
this situation is not recommended.
1
/
2" W x 37
3
/4
" H and 4
1
/
2" above
FRONT VIEW
TOP & SIDE VIEWS
Printed in the U.S.A.