Halsey Taylor OVL-II SER-Q User Manual

GreenSpec®Listed,
High Efficiency OVL-II
Series Bi-Level
MODEL OVL-II™SER-GRN-VR
This water cooler is certified to
NSF/ANSI 61-Annex G, AB 1953.
GENERAL
GreenSpec ed, bi-level wall-mounted water cooler designed to be easily accessible to physically challenged and able-bodied individuals. When properly installed, unit meets state and federal require­ments as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
FOUNTAIN
Oval shape fountain, non-corrosive stainless steel, with brushed satin finish. Contour-formed basin with rounded corners and edges. Oval fountain shape requires less neck extension and bending for the wheel chair user.
WATER CONSERVATION BUBBLER
Designed to reduce water usage while still delivering a satisfying stream. Vandal-resistant bubbler is one-piece, chrome-plated, with integral hood guard design to prevent contamination from other users, airborne deposits and tampering.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
PUSHBAR ACTUATION MECHANISM
Self-closing, semi-circular push bar can be actuated at any point on its 180° radius.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
REFRIGERATION SYSTEM
High-Efficiency, hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and self­lubricated fan cools copper/aluminum condenser. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
®
Listed, modular, electric refrigerat-
MOUNTING FRAME
Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation.
PANELS
Constructed of stainless steel number 300 series with satin finish. Removable lower panel provides access to plumbing and refrigeration system. Panels overlap wall opening
SUGGESTED SPECIFICATIONS
Shall be GreenSpec®Listed. Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbar valve on front, contour-formed basin to eliminate splashing and standing water, and rounded corners and edges.Bubbler shall be one-piece, lower-flow, vandal-resistant. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/ chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61-Annex G, AB 1953 , and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice. See Halsey Taylor website for most current spec sheet.
1
/
.
2"
Barrier-Free Cooler
Standard finish is Stainless Steel
Optional Accessories (extra cost)
Water Filter
Cane Apron
Each OVL-II™ SER-GRN-VR consists of 3 cartons as follows:
Mounting Frame Cooling Unit-SJ8GRN Fountain, Panels & Misc. Parts
JOB NAME:
ENGINEER/CONTRACTOR NAME:
APPROVAL:
DATE:
OVL-II™BARRIER-FREE SERIES
Model GPH Capacity Base F.L. Shipping Rated No. Cooled to 50° F* Rate Amps Weight Watt
70°F 80°F 90°F†100°F
OVL-II™ SER-Q 9.3 8.3 7.5 6.8 7.5 2.8 135 260
* With projector service and tap water at 80° F
For additional specification of the cooling unit, see specification sheet for Model SJ8 Remote in this catalog.
UL listed and complies with ARI Standard 1010
Trap and service stop not included
Ambient Air Temp
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
Cap. lb. Usage
halseytaylor.com
A38 / 7-2010
OVL-II™SER-GRN-VR
GreenSpec®Listed, High Efficiency,
OVL-II
Barrier-Free
Bi-Level Cooler
(CONTINUED)
ELECTRICAL DATA
Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase.
WALL OPENING
IMPORTANT: It is necessary to create a wall opening 37 the floor line.
MOUNTING INSTRUCTIONS
Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper panel to hanger on frame. Fountains are to be attached to panel and wall frame. Water service lines, waste lines and electrical are assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.)
Installation requires trap to be installed in wall. Trap and service stop not included.
OPERATING PRESSURES:
Supply water - 105 psi maximum
Minimum 40 psi supply line pressure required in special circumstances where both sides of bilevel are in use simultaneously to ensure adequate stream height. Use of water filter in this situation is not recommended.
1
/
2" W x 37
3
/4
" H and 4
1
/
2" above
FRONT VIEW
TOP & SIDE VIEWS
Printed in the U.S.A.
Loading...