Halsey Taylor OVL-II-EREE-Q, OVL-II-SREE-Q, OVL-II-ESREE-Q Owners Manual

OVL-I I
OVLEREEQ*G OVLSREEQ*G OVLESREEQ*G OVLSEREEQ*G
HALSEY TAYLOR OWNERS MANUAL
TM
Series Electronic Eye Barrier-Free Water Coolers Refrigerated Fountains with Back Panel
Figure
1 2 3 4
Model OVL-II-EREE-Q OVL-II-SREE-Q
OVL-II-SEREE-Q OVL-II-ESREE-Q
Description
OVL-II Series - Extended Reach
OVL-II Series - Standard Reach OVL-II Series - Dual Installation OVL-II Series - Dual Installation
INSTALLER
Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left in the plastic bag provided inside the installed unit for future reference.
Service to be performed by authorized service personnel only .
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to
available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an “electrolysis” effect occurring in the fountain. This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation. Any drain fittings provided by the installer should be made of plastic which will remainder of the building’s plumbing circuits.
1
electronically isolate the fountain from the
97882C - (Rev. F - 7/09)
OVLEREEQ*G OVLSREEQ*G OVLESREEQ*G OVLSEREEQ*G
1/4" O.D. TUBE
WA TER INLET
TO COOLER
NOTE: WA TER FLOW
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WA TER SUPPL Y
DIRECTION
SERVICE STOP
(NOT FURNISHED)
Figure 5 – Water Supply Connections
Item Part No. Description
1
2
3
4 5
6 7 8 9
10
11
12 13 14
15 16
17
18 19 20 21
22
23 24
97882C - (Rev. F - 7/09)
27688C 27689C 26990C 55836C 55991C 51546C 45396C
55905C 100322740560 160270508640
45400C 101570540560
51575C 110346220550 101637451550 161637308640
45398C
45682C
45683C 100023340560 161570808550
61313C
61314C
50986C
27006C
27342C
27000C
27344C
38417001
55840C
55839C
27691C
27754C
27692C
27755C
27004C
27340C
28328C
15005C
Bottom Cover - Standard Reach (EE) Bottom Cover - Extended Reach (EE) Bottom Cover - Standard Reach Push Arm Actuator Push Arm Actuator - A.G. Bubbler - S.S. Bubbler - A.G. Bubbler - EasyFlex (option) Bubbler Gasket Strainer Plate - S.S. Strainer Plate - A.G. Drain Gasket Packing Ring Drain Nut Friction Ring Drain Plug - S.S. Drain Plug - A.G. Drain Tube Drain Tube Waste Tube Gasket Slip Nut Regulator - W/Red Spring Regulator - W/Green Spring Regulator Holder Basin - S.S. Basin - A.G. Basin Liner - S.S. Basin Liner - A.G. Screw - #8-18 x .37 Top Plate - Actuator Bottom Plate - Actuator Extended Reach Arm (EE) - S.S. Extended Reach Arm (EE) - A.G. Standard Reach Arm (EE) - S.S. Standard Reach Arm (EE) - A.G. Standard Reach Arm - S.S. Standard Reach Arm - A.G. Regulator Mounting Bracket Nut - Retaining
BUILDING WA TER INLET
Parts List
2
Installation Package
The components for installation are packed in three separate boxes, regardless of the type of unit being installed. The boxes contain the following:
Box No. 1: Wall Frame(s) Box No. 2: Remote Chiller, SJ8-Q Box No. 3: Fountain(s), Arm(s) and Panels
Additional materials, as noted in the Parts List, are also shipped in these boxes.
Number Required
OVL-II
EREE-Q
-
1
-
-
­1 1 1 2 1 1 1 1 2 1 1 1
­1 1 1 1
­1 1 1 1 1 2
-
­1 1
-
-
-
-
-
-
OVL-II
SREE-Q
1
-
-
-
­1 1 1 2 1 1 1 1 2 1 1
­1
­1 1 1
­1 1 1 1 1 2
-
-
-
­1 1
-
-
-
-
OVL-II
SEREE-Q
­1 1 1 1 2 2 2 4 2 2 2 2 4 2 2 2 1 1 2 2 1 1 2 2 2 2 2 2 1 1 1 1
-
­1 1 1 1
OVL-II
ESREE-Q
­1 1 1 1 2 2 2 4 2 2 2 2 4 2 2 2 1 1 2 2 1 1 2 2 2 2 2 2 1 1 1 1
-
­1 1 1 1
See Fig.
25 25 23 20
20 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27 24, 27
27
22 22, 27
24
24
24
24
7, 10
20
20
25
25
25
25
24
24
21
22
OVLEREEQ*G OVLSREEQ*G OVLESREEQ*G OVLSEREEQ*G
Parts List Continued
Item
25 26 27 28 29 30 31 32
33
34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51
Part No. Description
27008C 70856C 70854C 50198C 51667C 28327C 28326C 22797C 27886C 22799C 27888C 26958C 27890C 22795C 27892C 26833C 27894C 27026C 27896C 55996C 70683C 70682C 56092C 56159C 27687C 31375C 36286C 31384C 40045C 50203C 50595C 51409C 56082C 70016C 70989C 75507C 70817C
Reaction Bracket Screw - #10-24 x .38 PHMS Rod - Pivot Bushing Snap Bumper - Regulator Valve Assy Arm - Regulator Activating Arm - Regulator Adjustment Upper Panel (OVL-II EREE) - S.S. Upper Panel (OVL-II EREE) - A.G. Upper Panel (OVL-II SREE) - S.S. Upper Panel (OVL-II SREE) - A.G. Upper Panel (OVL-II SEREE) - S.S. Upper Panel (OVL-II SEREE) - A.G. Upper Panel (OVL-II ESREE) - S.S. Upper Panel (OVL-II ESREE) - A.G. Lower Panel (OVL-II EREE/SREE) - S.S. Lower Panel (OVL-II EREE/SREE) - A.G. Lower Panel (OVL-II SEREE/ESREE) - S.S. Lower Panel (OVL-II SEREE/ESREE) - A.G. Strainer (Supplied with Chiller) Union - 1/4” Tee - 1/4” Poly Tubing - 1/4” (Cut To Length) Bubbler Nipple Assembly Regulator Mounting Bracket Solenoid Valve Assy. Power Cord Sensor - Clear Hex Nut - Unplated Strain Relief Bushing Snap Bushing .50 I.D. Spacer Regulator Nut Hex Nut - #10-32 Screw - #8-36 x .37 Ground Fitting - 1/4 NPTF Fitting - Elbow 1/4”
OVL-II
EREE-Q
-
1
-
-
-
-
­1 1
-
-
-
-
-
­1 1
-
­1 1
­1 1 1 1 1 1 1 1 1 2 1 2 1 2 1
OVL-II
SREE-Q
­1
-
-
-
-
-
-
­1 1
-
-
-
­1 1
-
­1 1
­1 1 1 1 1 1 1 1 1 2 1 2 1 2 1
OVL-II
SEREE-Q
1 2 1 4 1 1 1
-
-
-
­1 1
-
-
-
­1 1 1
­1 1 2 1 1 1 1 2 1 1 2 1 2 1 2 1
OVL-II
ESREE-Q
1 2 1 4 1 1 1
-
-
-
-
-
­1 1
-
­1 1 1
­1 1 2 1 1 1 1 2 1 1 2 1 2 1 2 1
See Fig.
21 21 21 21 21 21
21 13, 27 13, 27 13, 27 13, 27
13, 24, 27 13, 24, 27 13, 24, 27 13, 24, 27
15, 27 15, 27
15, 24, 27 15, 24, 27
17, 18
17
18 17, 18
27
25
7, 10, 26
26
25 22, 27
25
27
25
27
25
26
26
26
NOTE: S.S. means Stainless Steel
A.G. means Aztec Gold
3
97882C - (Rev. F - 7/09)
OVLEREEQ*G OVLSREEQ*G OVLESREEQ*G OVLSEREEQ*G
OVL-II SEREE-Q – OVL-II ESREE-Q
Figure 6 – OVL-II SEREE-Q Rough-In
Models
1. Cut a rectangular wall opening 37-1/2” (953 mm) W x 37-3/4” H (959 mm) and 4-1/2” (114 mm) above the floor line (see Figure 7). The dimensions are required to obtain proper rim and bubbler heights for compliance with ANSI standard A117.1.
2. Reinforce the wall opening on all sides to adequately support the water fountain. This reinforcement must support up to 150 lbs. static load and provide a means for securing the frame assembly in place.
NOTE: Building construction must allow for adequate air
flow on both sides and top of remote chiller unit a minimum of 4” (102 mm) is required.
3. Install plumbing and electrical rough-ins. A junction box for a (3) wire, 10 amp branch circuit is provided on the inside of the chiller. (Standard 120 Volts, 60 Hz, and single phase.)
4. Remove frames and related hardware from packaging. Release the two shelf rods by cutting cable ties. Attach the two frames together through the upright supports with (4) 5/16” x 3/4” (19 mm) long bolts and nuts (provided). Tighten securely.
40
18
REVERSED CONFIGURA TION:
HIGHER UNIT ON THE RIGHT
ST ANDARD CONFIGURATION:
HIGHER UNIT ON THE LEFT
Figure 7 – Rough-In Assembly Dual-Station Mounting Frames