INSTALLER
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.
Service to be performed by authorized service personnel only .
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to
available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an
“electrolysis” effect occurring in the fountain. This may result in water which has a metallic taste to it or has a
noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the installation,
and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation. Any drain
fittings provided by the installer should be made of plastic which will
remainder of the building’s plumbing circuits.
1
electronically isolate the fountain from the
97882C - (Rev. F - 7/09)
OVLEREEQ*G OVLSREEQ*G OVLESREEQ*G OVLSEREEQ*G
1/4" O.D. TUBE
WA TER INLET
TO COOLER
NOTE: WA TER FLOW
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WA TER SUPPL Y
DIRECTION
SERVICE STOP
(NOT FURNISHED)
Figure 5 – Water Supply Connections
ItemPart No.Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
97882C - (Rev. F - 7/09)
27688C
27689C
26990C
55836C
55991C
51546C
45396C
55905C
100322740560
160270508640
45400C
101570540560
51575C
110346220550
101637451550
161637308640
45398C
45682C
45683C
100023340560
161570808550
61313C
61314C
50986C
27006C
27342C
27000C
27344C
38417001
55840C
55839C
27691C
27754C
27692C
27755C
27004C
27340C
28328C
15005C
Bottom Cover - Standard Reach (EE)
Bottom Cover - Extended Reach (EE)
Bottom Cover - Standard Reach
Push Arm Actuator
Push Arm Actuator - A.G.
Bubbler - S.S.
Bubbler - A.G.
Bubbler - EasyFlex (option)
Bubbler Gasket
Strainer Plate - S.S.
Strainer Plate - A.G.
Drain Gasket
Packing Ring
Drain Nut
Friction Ring
Drain Plug - S.S.
Drain Plug - A.G.
Drain Tube
Drain Tube
Waste Tube Gasket
Slip Nut
Regulator - W/Red Spring
Regulator - W/Green Spring
Regulator Holder
Basin - S.S.
Basin - A.G.
Basin Liner - S.S.
Basin Liner - A.G.
Screw - #8-18 x .37
Top Plate - Actuator
Bottom Plate - Actuator
Extended Reach Arm (EE) - S.S.
Extended Reach Arm (EE) - A.G.
Standard Reach Arm (EE) - S.S.
Standard Reach Arm (EE) - A.G.
Standard Reach Arm - S.S.
Standard Reach Arm - A.G.
Regulator Mounting Bracket
Nut - Retaining
BUILDING WA TER
INLET
Parts List
2
Installation Package
The components for installation are packed in three
separate boxes, regardless of the type of unit being
installed. The boxes contain the following:
1.Cut a rectangular wall opening 37-1/2” (953 mm) W x
37-3/4” H (959 mm) and 4-1/2” (114 mm) above the floor line
(see Figure 7). The dimensions are required to obtain proper
rim and bubbler heights for compliance with ANSI standard
A117.1.
2.Reinforce the wall opening on all sides to adequately
support the water fountain. This reinforcement must support
up to 150 lbs. static load and provide a means for securing
the frame assembly in place.
NOTE:Building construction must allow for adequate air
flow on both sides and top of remote chiller unit a
minimum of 4” (102 mm) is required.
3.Install plumbing and electrical rough-ins. A junction box
for a (3) wire, 10 amp branch circuit is provided on the
inside of the chiller. (Standard 120 Volts, 60 Hz, and single
phase.)
4.Remove frames and related hardware from packaging.
Release the two shelf rods by cutting cable ties. Attach the
two frames together through the upright supports with (4)
5/16” x 3/4” (19 mm) long bolts and nuts (provided). Tighten
securely.