OVL-E * C , OVL-S * C
Halsey T aylor Owners Manual
Non-Refrigerated Fountains
OVL - E OVL - S
Installer
T o assure you install this model easily and correctly ,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE ST ARTING THE
INST ALLATION. CHECK YOUR INSTALLA TION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WA TER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y
OCCUR A WA Y FROM THE BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A
FOUNT AIN, CREA TING AN ELECTROL YSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN
THE MET AL CONTENT OF THE W A TER. THIS CONDITION IS A VOIDABLE BY USING THE PROPER
MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE
OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNT AIN FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPL Y
NOTE: WA TER FLOW
DIRECTION
BUILDING WA TER INLET
SERVICE STOP
(NOT FURNISHED)
FIG. 1
PAGE 1
OPERA TION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS
SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
FIG. 2
97089C (Rev. K - 4/07)
OVL-E * C , OVL-S * C
OVL - E
OVL - S
LEGEND:
A = 1-1/4" O.D. Waste Tube (Trap & Elbow Not Provided)
B = 3/8" O.D. Unplated Copper Tube Connect (Water Inlet)
FIG. 3
97089C (Rev. K - 4/07)
PAGE 2