Halsey Taylor HWF172 Water Sentry VII User Manual

GENERAL
Designed to remove cysts, such as cryptrosporidium and giardia, lead particles and chlorine. Also reduces odors and discoloration from incoming water.
Features include Quick-Disconnect, 1⁄4turn installation. Automatic inlet shut-off valve that closes when filter is removed. Outer protective wrap. Spun Polypropylene prefilter mesh to prevent large, coarse sediment and particles from entering and clogging filter media. High-grade filter is made with activated carbon and patented ATS lead-removal media. Radial flow-thru design provides more surface area for untreated water while final filter mesh pre­vents loose carbon from entering water. Cap and housing shall be made of rust and corro­sion free plastic. Lead and cyst reduction filter shall be Halsey Taylor Water Sentry VII.
Designed specifically for use with the following series of Halsey Taylor water coolers:
HAC, HACBL, WM**, SCWT** series, S series and WMBL. Can also be used on OVLSER, OVLER, HRF, RC & BFMR units but must be mounted into the wall behind the unit’s backplate. CANNOT be used in the HTV, SW, WC, HBW or the unrefrigerated versions of the HRF and OVL series.
**For water cooled models contact the factory.
RECOMMENDED USE CONDITIONS
Capacity......................1,500 Gallons (5678 £)
Flow rate .....................0.75gpm (2.8 l/m)
Temperature................40-120°F (4 - 49°C)
Maximum Pressure.....105psi (724 Kpa)
Minimum Pressure......20psi (138 Kpa)
PERFORMANCE TEST CONDITIONS*
Capacity......................1,500 Gallons (5678 £)
Flow rate .....................0.75gpm (2.8 l/m)
Pressure......................60 psi (4.2 Kg/cm2)
Temperature................68-70°F (20-21°C)
*Performance will vary depending on local water conditions.
WATER CONNECTION
Water Inlet for 3⁄8" O.D. Tube
Water Outlet for 1⁄4" O.D. Tube
STANDARDS
This filter has been tested to the following NSF International standards: NSF/ANSI Standards 42 Chlorine, Particulate, and Taste and Odor. NSF/ANSI Standard 53 for Reduction of Lead and Cyst.
KIT CONSISTS OF:
Filter
Filter head
Mounting bracket
1/4" polytubing, connectors and screws
Installation instructions
Performance Data Sheet
Shipping Weight: 4 lbs.
55897C REPLACEMENT FILTER
Replacement filter for Water Sentry VII. Replacement instructions included. Filter should be replaced every 1,500 gallons (5678 liters) or approximately one (1) year after installation. Use part # 55897C when ordering replacement filter.
98262C FILTER MONITOR
Optional accessory monitors the number of gallons used for determining when to change filter. When a filter change is due, the monitor will beep when water is flowing. Monitor operates on 2 AA alkaline batteries (not included). Installation instructions included.
NOTE: Continued product improvement makes specifications subject to change without notice. See Halsey Taylor website for most current spec sheet.
E12 / 11-2007
MODEL HWF172 Water Sentry VII™
Reduction Filter
Cyst and Lead
HALSEY TAYLOR, DIV. OF ELKAY MFG., 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
halseytaylor.com
HWF172
Filter Monitor
98262C
Replacement Filter
55897C
JOB NAME:
ENGINEER/CONTRACTOR NAME:
APPROVAL:
DATE:
Printed in the U.S.A.
HWF172 Water Sentry VII™
Cyst and Lead Reduction Filter
(CONTINUED)
INSTALLATION INSTRUCTIONS
The filter must be installed in compliance with all state and local laws and regulations governing the installation and use of this product.
Disconnect electrical power and close water supply valve before proceeding.
The filter must be installed on the water inlet line.
Flow indicator (arrow) on filter should point in the same direction as the water flow.
After installing new filter, open water supply valve and check for leaks. Flush system sufficiently (approximately 3 minutes) to effectively remove small residue of carbon fines.
NOTE: A water shutoff valve should be installed on the incoming water line to aid in future servicing of filter.
CAUTION
Filter is designed to reduce lead from incoming water to levels below EPA requirements. Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system.
Use on water inlet line only. Do not allow installed filter to freeze. Do not attached hot water line to filter.
Filter should be replaced every 1,500 gallons (5678 liters) or approximately one (1) year after installation.
FRONT VIEW
WARRANTY
The Halsey Taylor Water Sentry®VII is warranted to be free from defects in material and workmanship for a period of one year from the date of installation. Warranty is limited to repair or replacement of defective component.
Loading...