This water cooler is certified to
NSF/ANSI 61.
GENERAL
Self-contained, electric refrigerated wall-mounted
water cooler designed to be easily accessible
to physically challenged individuals. When
properly installed, unit meets state and federal
requirements as defined by the Americans with
Disabilities Act for both children or adults.
Unit is certified to NSF/ANSI 61, and meets
requirements of the Safe Drinking Water Act.
Unit provides 50° F water at 80° F inlet water
and 90° F ambient. Unit is UL listed for
indoor and outdoor service.
CABINET
Stainless steel panels resists wear and corrosion.
Durable satin finish helps hide water spots and
fingerprints.
COOLER TOP
Non-corrosive stainless steel cooler top,
number 300 series with satin finish resists
stains and corrosion and is easy to maintain.
Anti-splash ridge reduces splatter. Contoured
to insure proper drainage.
BUBBLER
Vandal-resistant bubbler is one-piece, chromeplated. Unit has integral hood guard design to
prevent contamination from other users,
airborne deposits and tampering.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does
not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to
prevent tampering. Unit resists corrosion and
liming. A constant stream height is automatically
maintained under line pressures that vary from
20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps
particles of 140 microns or larger before they
enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling
temperature of storage tank water. Factory set
at 50° F Adjustable ± 5° F.
STORAGE TANK
Non-pressurized stainless steel
evaporator/storage tank for long life.
Waterways are certified to NSF/ANSI 61,
far exceeding the requirements of the
Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor
with lifetime lubrication and built-in overload
protection, efficient capillary sizing, large
capacity dryer-strainer, and self-lubricated fan
cools copper/aluminum condenser. System
uses R134A refrigerant. Protected by Halsey
Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining
6" (152mm) minimum clearance from
cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 7.8 GPH of 50° F water at 90° F
ambient and 80° F inlet water. Shall have
stainless steel basin with removable drain
strainer. Bubbler shall be one-piece, vandalresistant. Separate valve and automatic stream
regulator shall be mounted within cabinet.
Refrigeration system shall employ high
efficiency, positive start compressor using
R134A, non-pressurized tank with totally
encapsulated insulation and be controlled by
positive sensing thermostat. Unit shall comply
with ANSI 117:1 and ADA for visual and motion
disabilities. Unit shall be UL listed for outdoor
service. The manufacturer shall certify the unit
to meet the requirements of NSF/ANSI 61, and
the Safe Drinking Water Act. Unit complies
with ARI Standard 1010.
NOTE: Continued product improvement
makes specifications subject to change
without notice. See Halsey Taylor website
for most current spec sheet.
Stainless Steel Finish Only
Optional Accessories (extra cost)
■■
Water Filter**
■■
Frost-Resistant Model
(factory installed only - HVR8FR-CHILD ADA)
■■
220-240V 50 Hz
■■
220-240V 60 Hz
■■
Louver Screens
** Water filter option not available for
frost-resistant models
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
A10 / 8-2007
MODEL:■■HVR8 ADA
■■
HVR-L/R ADA
Wall-Mounted
Barrier-Free Cooler
Vandal-Resistant
Indoor/Outdoor
halseytaylor.com
HRV BARRIER-FREE SERIES
Model GPH Capacity Base F.L. Shipping Rated
No. Cooled to 50° F* Rate Amps Weight Watt
Ambient Air Temp
Cap. lb. Usage
70°F 80°F 90°F†100°F
HVR8 ADA 9.4 8.6 7.8 7.0 7.8 4.0 66 370
HVR8FR ADA 9.4 8.6 7.8 7.0 7.8 6.2 68 620
HVR8 ADA 220-240V 50 Hz 7.9 7.2 6.5 5.9 6.5 2.0 66 370
HVR8 ADA 220-240V 60 Hz 9.4 8.6 7.8 7.0 7.8 2.0 66 370
* With projector service and tap water at 80° F
†
UL listed and complies with ARI Standard 1010
Trap and service stop not included