Halsey Taylor HTV8BLEE-Q User Manual

This water cooler is certified to
NSF/ANSI 61.
GENERAL
Self-contained, electric refrigerated wall-mounted bi-level water cooler with softly rounded corners and edges, designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for both children or adults. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
CABINET
Molded two-tone gray space-age polymer with softly rounded edges. Resistant to impact, wear, corrosion, heat and sunlight.
COOLER TOP
Non-corrosive stainless steel cooler top, number 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash design reduces splatter. Contour design and integral strainer insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two­stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
AUTOMATIC ACTUATION
Model HTV8BLEE-Q features infra-red light beam emitting sensor and a solenoid valve. Upon interruption of the light beam, the sensor actuates the solenoid valve to flow water. User does not have to touch the water cooler to obtain a drink of water. The water flow is automatically shut-off after 30 seconds or earlier if the user leaves the sensing range. Supplied with a built-in time delay to avoid nuisance actuation from passers-by.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
SOLENOID VALVE / INLET STRAINER
Self-closing solenoid valve includes easily cleaned in-line strainer that screens particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F.
STORAGE TANK
Stainless steel evaporator/storage tank for long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and self-lubricated fan cools copper/aluminum condenser. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 7.6 GPH of 50° F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with integral drain strainer. Bubbler shall be two-stream, mound building type. Separate valve and automatic stream regulator shall be mounted within cabinet. Refrigeration system shall employ high efficiency, positive start compressor using R134A, evaporator tank with totally encapsulated insulation and be controlled by positive sensing thermostat. Shall have electronic eye water controls for hands-free operation. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice. See Halsey Taylor website for most current spec sheet.
NOTE: Water will only flow from bubbler when unit has electrical connection.
\
Standard finish is Two-Tone Gray Molded.
Optional Accessories (extra cost)
Water Filter
Easy-Flex™Bubbler
MLP200 In-Wall Support Carrier
Cane Touch Apron
Vandal-Resistant Kit
For Stainless Steel Applications Use:
HAC8EEBL-Q CHILD SS
Optional Features:
Personalized Graphics (Contact your local representative)
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
A8 / 1-2009
MODEL HTV8BLEE-Q
Electronic Eye
Bi-Level
Barrier-Free Cooler
halseytaylor.com
HTV-Q BARRIER-FREE SERIES
Model GPH Capacity Base F.L. Shipping Rated No. Cooled to 50° F* Rate Amps Weight Watt
Ambient Air Temp
Cap. lb. Usage
70°F 80°F 90°F†100°F
HTV8BLEE-Q 9.6 8.8 7.6 7.2 7.6 4.0 80 370
* With projector service and tap water at 80° F
UL listed and complies with ARI Standard 1010
Trap and service stop not included
JOB NAME:
ENGINEER/CONTRACTOR NAME:
APPROVAL:
DATE:
Printed in the U.S.A.
HTV8BLEE-Q
Electronic Eye Bi-Level Barrier-Free Cooler
(CONTINUED)
MOUNTING HEIGHT
Mounting height recommended 30
1
/
4" from
basin to floor. May be mounted at any desired height. Check local codes.
MOUNTING INSTRUCTIONS
Mount trap and install service stop to building supply line. Anchor hanger bracket securely to wall with six fasteners. To insure proper engaging of waste line into trap, centerline of trap must be 7" from wall face. Remove slip nut and gasket from trap and install on waste line tube. Hang cooler on bracket and engage waste line tube into trap inlet. Centerline height of waste outlet will vary from floor line depending on mounting height. Connect service stop to solenoid valve using 3/8" supply tube. Secure bottom of cooler to wall using holes provided.
Trap and service stop not included.
OPERATING PRESSURES:
Supply water - 20 to 105 psi. Minimum 40 psi supply line pressure required in special circumstances when both sides of bilevel are in use simultaneously to ensure adequate stream height. Does not apply to non-refrigerated units.
ELECTRICAL
Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
FRONT VIEW / WALL LAYOUT
SIDE VIEW
8
1
7
28
7
1
(PREFFERED LOCATION)
(ALT. LOCATION)
6
4
1
8
5
Legend:
A = RECOMMENDED WATER SUPPLY
LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
B = RECOMMENDED LOCATION FOR
WASTE OUTLET 1-1/2" O.D. DRAIN C = 1-1/2" TRAP NOT FURNISHED D = ELECTRICAL SUPPLY (3) WIRE
RECESSED BOX (DUPLEX REQUIRED) E = INSURE PROPER VENTILATION BY
MAINTAINING 6" (152 mm) (MIN.)
CLEARANCE FROM CABINET
LOUVERS TO WALL F = 5/16" BOLT HOLES FOR FASTENING
UNIT TO WALL
* Adult ADA requirement (shown) - 27" (686mm);
Child ADA requirement - 24" (608mm). Adjust all other measurements accordingly.
NOTE: Halsey Taylor's recommended orifice mounting height for children 38" to 46" tall (approx. four through seven years old) is 23" from the finished floor.