Halsey Taylor HTSR -Q User Manual

This water cooler is Classified by
Underwriters Laboratories, Inc. in accordance with ANSI/NSF 61, Section 9 - 1997b.
GENERAL
Modular, electric refrigerated, wall-mounted water cooler designed to be easily accessible to able-bodied individuals. Unit is certified to ANSI/NSF 61 Sec. 9 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
FOUNTAIN
Face-mounted, one-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish and contour-formed basin.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSH BAR ACTUATION MECHANISM
Self closing, light-touch push bar with raised letters for the visually impaired.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before the enter the waterway.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
MOUNTING FRAME
Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation.
PANELS
Constructed of stainless steel, number 300 series with satin finish. Removable lower panel provides access to plumbing and refrigeration system. Panels overlap wall opening 1⁄2˝.
SUGGESTED SPECIFICATIONS
Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include pushbar valve on front, contour-formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, two-stream, mound­building type. Cooling unit shall have a high efficiency positive start compressor using R134A with pressurized counterflow cooling evaporator/chiller. The manufacturer shall certify the unit to meet the requirements of ANSI/NSF 61, Section 9 and the Safe Drinking Water Act. Shall be certified to meet ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice.
Standard finish is Stainless Steel Optional Accessories (extra cost)
Cane Apron
Vandal-Resistant Kit
Water Filter
Lead Filter
Easy-Flex™Bubbler
Each HTSR consists of 3 cartons as follows:
Mounting Frame Cooling Unit-SJ8 Fountain, Panels & Misc. Parts
Trap and service stop not furnished.
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
C10 / 9-2002
MODEL: ■HTSR -Q
Face-Mounted Cooler
Classic
Series
www.halseytaylor.com
HT FACE-MOUNTED SERIES
Model GPH Capacity Base F.L. Shipping Rated No. Cooled to 50° F* Rate Amps Weight Watt
Ambient Air Temp
Cap. lb. Usage
70°F 80°F 90°F 100°F
HTSR-Q 7.3 8.3 7.5 6.8 7.5 4.5 120 400
* With projector service and tap water at 80° F
For additional information on the cooling unit, see the specification sheet for Model SJ8 remote chiller in this catalog.
UL listed and certified to meet ARI Standard 1010
Trap and service stop not furnished.
Printed in the U.S.A.
Classic™Series Face-Mounted Cooler
(CONTINUED)
WALL OPENING
IMPORTANT: It is necessary to create a wall opening 183⁄4˝ W x 373⁄4˝ H, and 41⁄2˝ above the floor line.
MOUNTING INSTRUCTIONS
Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper fountain panel to hanger on frame. Fountain is to be attached to panel and wall frame. Water service line, waste line and electrical is assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountain and chiller. For details see the installation instructions.
OPERATING PRESSURES:
Supply water-105 psi maximum
ELECTRICAL DATA
Junction box for a (3) wire 10 AMP branch circuit. Standard 120 volt, 60 Hz, single phase.
TOP & SIDE VIEW
FRONT VIEW
LEGEND:
A = 3/8” O.D. TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS B = 1-1/4” O.D. WATER TUBE (ELBOW & TRAP NOT PROVIDED) C = ELECTRICAL INLET