This fountain is Classified by
Underwriters Laboratories, Inc. in accordance with ANSI/NSF 61, Section 9 - 1997b.
GENERAL
Face-mounted fountain, one-piece, non-corrosive stainless steel number 300 series with brushed satin finish. Contour­formed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSH BAR ACTUATION MECHANISM
Self closing, light-touch push bars with raised letters for the visually impaired.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns o r l a r g e r b e f o r e t h e y enter the waterway.
WATER INLET
3/8˝ O.D. Tubing
DRAIN OUTLET
1-1/4˝ tube outlet for 1-1/4˝ slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbar on the front, contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of ANSI/NSF 61, Section 9 and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice.
Standard finish is Stainless Steel
Optional Accessories (extra cost)
Cane Apron
Vandal-Resistant Kit
Easy-Flex™Bubbler
Each HTS consists of 1 carton of the following:
Fountain, and Misc. Parts
Trap and service stop not furnished.
Copper tube to water supply connection not furnished
Shipping weight: 18 lbs.
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
D13 / 9-2002
MODEL:■HTS
Face-Mounted Fountain
Classic
Series
www.halseytaylor.com
Printed in the U.S.A.
Classic™Series Face-Mounted Fountain
(CONTINUED)
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing. For wall support required locations see installation instructions provided with fountain. Water service line and waste line are to be assembled as required. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.)
CAUTION – Fountain must be securely
bolted to wall
OPERATING PRESSURES
Supply water-105 psi maximum IMPORTANT: For wall support required locations
see installation instructions provided with fountain.
FRONT VIEW / WALL LAYOUT SIDE VIEW
NOTE: A service supply stop should be installed at the fountain inlet line.
LEGEND: A = 3/8˝ O.D. TUBE CONNECT (WATER SUPPLY) B = 1-1/4˝ O.D. WASTE TUBE (ELBOW AND TRAP NOT PROVIDED)