Halsey Taylor HTHBWF-OVLSER-I User Manual

Satisfying Thirsts Since 1912
OVL-II™ Series Bi-Level
Wall Mount Refrigerated Fountain
Barrier-Free with HydroBoost
®
MODEL: HTHBWF-OVLSER-I
GENERAL
Complete water station including HydroBoost® bottle lling station and OVL-II™
style water fountain. Two face-mounted fountains, one-piece, non-corrosive stainless steel number 300 series with brushed satin nish. Contour-formed basins with softly rounded corners and edges reduces splatter, insures proper drainage and prevents
standing waste water. Designed to be easily accessible to both physically challenged
and able-bodied individuals. Ideally suited for installation in public areas. Model meets state and federal requirements as dened by the Americans with Disabilities Act.
HYDROBOOST® BOTTLE FILLING STATION
Sensor-activated enhanced with user interface graphics. Quick ll rate is 1.1 gallons per minute. Laminar ow provides a clean ll with minimal splash and easy mainte­nance. Key plastic components are integrated with silver ion anti-microbial protection
to inhibit growth of mold and mildew.
SILVER ION ANTI-MICROBIAL PROTECTION
Key plastic components are integrated with silver ion anti-microbial protection to inhibit
growth of mold and mildew.
GREEN COUNTER™
Visually displays count of plastic bottles saved from landfills. (Based on
20 oz. bottles for refrigerated models).
DOUBLE BUBBLER™
Features an exclusive one-piece, chrome plated two-stream mound-building bubbler with non-removable anti-squirt feature. It’s integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
PANEL
Constructed of stainless steel, No. 300 Series with satin nish.
MOUNTING FRAME
Mounting frame is manufactured of corrosion resistant, galvanized steel. Open con­struction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists cor-
rosion and liming. A constant stream height is automatically maintained under line
pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before
they enter the waterway.
WATER INLET - 3/8” O.D. Tubing. DRAIN OUTLET - 1-1/2” tube outlet for 1-1/2” slip joint connection. (P-Trap not included.)
REFRIGERATION SYSTEM (Model HTHBWF-OVLSER-I) Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efcient capillary sizing, large capacity dryer-strainer, and self-
lubricated fan cools copper/aluminum condenser. System uses R134A refrigerant.
Protected by Halsy Taylor’s Limited 5 Year Warranty.
LEAD REDUCTION FILTER WITH FILTER LIFE INDICATOR
Equipped with the HWF3000 WaterSentry® Plus Filter. Quick-Disconnect, ¼ turn installation and automatic inlet shut-off valve that closes when lter is re­moved. High-grade lter is made with activated carbon and patented ATS lead­removal media. Certied to NSF/ANSI 42 for Chlorine-Class 1, Particulate-
Class 1 and Taste and Odor and NSF/ANSI 53 for Lead Reduction. Green,
yellow and red LEDs visually indicate when lter maintenance is required.
CAPACITIES CHART
GPH Capacity Cooled to
Model
No.
70°F 80°F 90°F 100°F
HTHB-OVLSER-I
Note: Continued product improvement makes specication subject to change
without notice. See Halsey Taylor website for most current spec Sheet.
9.3 8.3 7.5 6.8 7.5 5 174 390
50°F
Ambient Air Temp.
Base
Rate
Capacity
F.L.A. Amps
Shipping
Weight
Rated
Watt
Usage
halseytaylor.com
HALSEY TAYLOR, 2222 Camden Court, OakBrook, IL 60523
OVL Fountain With Bottle Filler and Filter
Rated for Indoor Use Only
SUGGESTED SPECIFICATIONS
Provides 8.0 gph of 50°F water at 90°F ambient and 80°F inlet water. Unit shall include bi-level oval fountains with integral bottle lling station construct­ed of stainless steel and ABS plastic. Bottle ller shall include electronic sen­sor for no-touch activation with automatic 20-second shut-off timer. Shall pro­vide 1.5 gpm ow rate with laminar ow to minimize splashing. Shall include anti-microbial protected plastic components to prevent mold and mildew. Fountains shall include front pushbutton activation. Shall have oval contoured fountain basins to minimize splashing and standing water and include rounded edges. Each projector shall be two­stream, mound-building type with integral hood guard and anti-squirt feature. Shall include the WaterSentry® Plus lter, certied to NSF/ANSI 41 and 53 for lead reduction, with visual lter monitor to indicate when replacement is necessary. Shall comply with ANSI 117:1 and ADA guidelines for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61 and 372, UL 399 and CAN/CSA 22.2 No. 120.
Replacement Filters: Available as Singles and Multi-packs. Order part numbers:
• 55898C (single)
• 55898C_3PK (three)
• 55898C_12PK (twelve)
• 55898C_24PK (twenty-four)
• 55898C_48PK (forty-eight)
Optional Accessories (Extra Cost)
Cane Touch Apron (Item #HTOVLAPR)
Access Panel (Item #ACCESS12X38-5)
Each HTHB-OVLSER-I consists of 2 cartons as follows: Fountain, Panel and Misc. Parts; Mounting Frame. Service stop not included. Total shipping weight: 120 lbs.
SPEC00054 09/2014
Model HTHBWF-OVLSER-I OVL-II™ Series Bi-Level Wall Mount Refrigerated Fountain Barrier-Free with HydroBoost
(continued)
®
Refer to diagrams for rough-in of plumb-
ing. Install mounting frame into wall per the installation instructions. Hang fountain
panel over the wall plate assembly. At­tach fountains to wall plate assembly. Water service line and waste line are to be assembled
as required. Final check for leaks and cor­rect functions of fountain should be made.
(For details see the installation instructions.)
CAUTION - Fountain must be securely bolted to wall.
MOUNTING INSTRUCTIONS:
Job Name: ______________________________
Date: __________________ Qty. ____________
Contact Info (Name, Phone, Email): __________
________________________________________
________________________________________
Approval: _______________________________
NOTE: A service stop (not included) must be installed at
the fountain inlet line.
NOTE: P-Trap (not supplied) to be installed per local building code.
NOTE: For wall support required locations see installation instructions provided with panel and fountains.
WALL LAYOUT
OPTIONAL BRACKET FOR ACCESS PANEL
5/16" SCREWS OR BOLTS
(12 REQ'D - NOT FURNISHED)
FRAME
5/16" HEX NUT
(4 REQ'D - PROVIDED)
P/N 111577343890
BOLT FRAMES TOGETHER
WITH 5/16" X 3/4" (19mm) BOLTS
(4 REQ'D - PROVIDED)
P/N 111577243890
INSTALL (2) SCREWS
(P/N 111008343890) IN FRAME
BEFORE INSTALLING IN OPENING
HOOK RODS (2) P/N 101567443730
OPERATING PRESSURES:
Supply water - 105 psi maximum
Minimum 40 psi supply line pressure required in special circumstances where both sides of bi-level are in use simultaneously to ensure adequate stream height. Use of water lter in this situation is not recommended.
ELECTRICAL
Hydroboost® station equipped with electric cord and
three-prong molded rubber plug for use with 15-
amp minimum receptacle. For the cooling unit, a
junction box for a (3) wire, 10 amp branch circuit is
provided. Rated at 115 volt, 60 Hz, single phase.
10 1/4"
260mm OPTIONAL FOR ACCESS PANEL
3" 76mm
51 15/16"
1319mm
4 1/2"
114mm
37 1/2" 952mm
Shown with two optional access panels installed
34 5/8" 879mm
20 7/16" 519mm
FINISHED FLOOR
®
9 7/8" 251mm
FRONT VIEW SIDE VIEW
38 1/2" 978mm
5/8"
18 11/16" 475mm
Activation Sensor
44 3/4" 1137mm
40" 1016mm
1 1/2" 38mm
34" 864mm
REQUIREMENT
1 1/2" 38mm
7" 179mm
3/8" O.D. COPPER TUBE
CHILLER. SHUT OFF
VALVE BY OTHERS
27" 686mm
ADA
16mm
17 5/16" 440mm
13 5/16" 338mm
WATER INLET ON
ELECTRICAL INLET
12"
305mm
SPACE REQ'D
BEHIND STUD WALL
BOTTLE FILLER
DRAIN
1-1/4" (32mm) WASTE TUBES FURNISHED
1/4" O.D. COPPER TUBE. COLD WATER OUTLET
8 1/16" 204mm
4 1/2" 114mm
1 1/8" 29mm
11" 279mm
Printed in the U.S.A.
28 1/2" 724mm
34 1/2" 876mm
Loading...