Satisfying Thirsts Since 1912
OVL-II™ Series Bi-Level
Filtered Wall Mount Fountain
Barrier-Free with HydroBoost
®
MODEL: HTHBWF-OVLSEBP-I
GENERAL
Complete water station including HydroBoost® bottle lling station and OVL-II™ style water fountain. Two face-mounted fountains,
one-piece, non-corrosive stainless steel number 300 series with
brushed satin nish. Contour-formed basins with softly rounded
corners and edges reduces splatter, insures proper drainage and
prevents standing waste water. Designed to be easily accessible
to both physically challenged and able-bodied individuals. Ideally
suited for installation in public areas. Model meets state and fed-
eral requirements as dened by the Americans with Disabilities Act.
HYDROBOOST® BOTTLE FILLING STATION
Sensor-activated enhanced with user interface graphics. Quick ll
rate is 1.5 gallons per minute. Laminar ow provides a clean ll with
minimal splash and easy maintenance. Equipped with an automatic
20-second shut-off timer. Key plastic components are integrated with
silver ion anti-microbial protection to inhibit growth of mold and mildew.
SILVER ION ANTI-MICROBIAL PROTECTION
Key plastic components are integrated with silver ion anti-microbial
protection to inhibit growth of mold and mildew.
GREEN COUNTER™
Visually displays count of plastic bottles saved from landfills. (Based on 20 oz. bottles for refrigerated models).
DOUBLE BUBBLER™
Features an exclusive one-piece, chrome plated two-stream
mound-building bubbler with non-removable anti-squirt feature. It’s
integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping
or twisting.
PANEL
Constructed of stainless steel, No. 300 Series with satin nish.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit
resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns
or larger before they enter the waterway.
WATER INLET
3/8” O.D. Tubing.
DRAIN OUTLET
1-1/2” tube outlet for 1-1/2” slip joint connection. (P-Trap not
included.)
OVL Fountain With Bottle Filler and Filter
Rated for Indoor Use Only
SUGGESTED SPECIFICATIONS
Unit shall include bi-level contoured fountains with integral bottle lling
station constructed of stainless steel and ABS plastic. Bottle ller shall
include electronic sensor for no-touch activation with automatic 20-second
shut-off timer. Shall provide 1.5 gpm ow rate with laminar ow to minimize
splashing. Shall include anti-microbial protected plastic components to inhibit mold and mildew. Fountains shall include front pushbutton activation.
Shall have contoured fountain basins to minimize splashing and standing
water and include rounded edges. Each projector shall be two-stream,
mound-building type with integral hood guard and anti-squirt feature. Shall
include the WaterSentry® Plus lter, certied to NSF/ANSI 41 and 53 for
lead reduction, with visual lter monitor to indicate when replacement is
necessary. Shall comply with ANSI 117:1 and ADA guidelines for visual and
motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61 and 372, UL 399 and CAN/CSA 22.2 No. 120.
Replacement Filters: Available as Singles and Multi-packs.
Order part numbers:
• 55898C (single)
• 55898C_3PK (three)
• 55898C_12PK (twelve)
• 55898C_24PK (twenty-four)
• 55898C_48PK (forty-eight)
LEAD REDUCTION FILTER WITH FILTER LIFE INDICATOR
Equipped with the HWF3000 WaterSentry® Plus Filter.
Quick-Disconnect, ¼ turn installation and automatic in-
let shut-off valve that closes when lter is removed. Highgrade lter is made with activated carbon and patented ATS
lead-removal media. Certied to NSF/ANSI 42 for Chlo-
rine-Class 1, Particulate-Class 1 and Taste and Odor and
NSF/ANSI 53 for Lead Reduction. Green, yellow and red
LEDs visually indicate when lter maintenance is required.
Note: Continued product improvement makes specication
subject to change without notice. See Halsey Taylor website
for most current spec Sheet.
www.halseytaylor.com
HALSEY TAYLOR, 2222 Camden Court, OakBrook, IL 60523
Optional Accessories (Extra Cost)
Cane Touch Apron (Item #HTOVLAPR)
Access Panel (Item #ACCESS12X38-5)
Each HTHB-WF-OVLSEBP-I consists of 2 cartons as follows:
Fountain, Panel and Misc. Parts; Mounting Frame.
Service stop not included. Total shipping weight: 120 lbs.
SPEC00052 09/2014
Model HTHBWF-OVLSEBP-I
OVL-II™ Series Bi-Level
Filtered Wall Mount Fountain
Barrier-Free with HydroBoost
(continued)
Refer to diagrams for rough-in of plumbing. Install mounting frame into wall per the
installation instructions. Hang fountain
panel over the wall plate assembly. Attach fountains to wall plate assembly. Water
service line and waste line are to be assembled
as required. Final check for leaks and correct functions of fountain should be made.
(For details see the installation instructions.)
CAUTION - Fountain must be securely bolted
to wall.
Job Name: ______________________________
Date: __________________ Qty. ____________
Contact Info (Name, Phone, Email): __________
________________________________________
________________________________________
Approval: _______________________________
MOUNTING INSTRUCTIONS:
®
NOTE: A service stop (not included) must be installed at
the fountain inlet line.
NOTE: P-Trap (not supplied) to be installed per local
building code.
NOTE: For wall support required locations see installation
instructions provided with panel and fountains.
WALL LAYOUT
OPTIONAL BRACKET
FOR ACCESS PANEL
5/16" SCREWS OR BOLTS
(20 REQ'D - NOT PROVIDED)
5/16" HEX NUT
(4 REQ'D - PROVIDED)
P/N 111577343890
FRAME
BOLT FRAMES TOGETHER
WITH 5/16" X 3/4" (19mm) BOLTS
(4 REQ'D - PROVIDED)
P/N 111577243890
INSTALL (2) SCREWS
(P/N 111008343890) IN FRAME
BEFORE INSTALLING IN OPENING
OPTIONAL BRACKET
FOR ACCESS PANEL
OPERATING PRESSURES:
Supply water - 105 psi maximum
Minimum 40 psi supply line pressure required in special
circumstances where both sides of bi-level are in use
simultaneously to ensure adequate stream height. Use
of water lter in this situation is not recommended.
ELECTRICAL
Hydroboost® station equipped with electric cord and
three-prong molded rubber plug for use with 15amp minimum receptacle. For the cooling unit, a
junction box for a (3) wire, 10 amp branch circuit is
provided. Rated at 115 volt, 60 Hz, single phase.
10 1/4"
260mm
OPTIONAL FOR
ACCESS PANEL
3"
76mm
31 3/4"
806mm
3"
76mm
25"
635mm
8 5/8"
219mm
OPTIONAL FOR
ACCESS PANEL
37 1/2"
952mm
Shown with two optional access
panels installed
34 5/8"
879mm
FINISHED FLOOR
®
FRONT VIEW
9 7/8"
251mm
38 1/2"
978mm
18 11/16"
475mm
OPTIONAL ACCESS
PANEL
OPTIONAL ACCESS
PANEL
Activation
Sensor
44"
1118mm
40"
1017mm
1 1/2"
38mm
34"
864mm
1 1/2"
38mm
REQUIREMENT
SIDE VIEW
7"
179mm
27"
686mm
ADA
17 5/16"
440mm
13 5/16"
338mm
5/8"
16mm
1-1/2" IPS
WASTE LINE
3/8" IPS
SUPPLY
8" (203mm) MINIMUM
12" (305mm) RECOMMENDED
FOR DRAIN CONNECTION
AND ACCESS TO
BOTTLE FILLER
ELECTRICALS
BOTTLE FILLER
DRAIN
28 1/2"
724mm
21 1/2"
546mm
16 1/2"
419mm
Printed in the U.S.A.
34 1/2"
876mm