Halsey Taylor HTHB-OVLSER-I User Manual

Satisfying Thirsts Since 1912
OVL-II™ Series Bi-Level
Wall Mount Refrigerated Fountain
Barrier-Free with HydroBoost
®
MODEL: HTHB-OVLSER-I
GENERAL
Complete water station including HydroBoost® bottle lling station and OVL-II™ style water fountain. Two face-mounted fountains, one-piece, non-corrosive stainless steel number 300 series with brushed satin n­ish. Contour-formed basins with softly rounded corners and edges reduc­es splatter, insures proper drainage and prevents standing waste water. De­signed to be easily accessible to both physically challenged and able-bodied individuals. Ideally suited for installation in public areas. Model meets state
and federal requirements as dened by the Americans with Disabilities Act.
HYDROBOOST® BOTTLE FILLING STATION
Sensor-activated enhanced with user interface graphics. Quick ll rate is 1.1 gallons per minute. Laminar ow provides a clean ll with minimal
splash and easy maintenance. Key plastic components are integrated with silver ion anti-microbial protection to inhibit growth of mold and mildew.
SILVER ION ANTI-MICROBIAL PROTECTION
Key plastic components are integrated with silver ion anti-microbial protection to inhibit growth of mold and mildew.
GREEN COUNTER™
Visually displays count of plastic bottles saved from landfills. (Based on 20 oz. bottles for refrigerated models).
DOUBLE BUBBLER™
Features an exclusive one-piece, chrome plated two­stream mound-building bubbler with non-removable anti-squirt feature. It’s integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
PANEL
Constructed of stainless steel, No. 300 Series with satin nish.
MOUNTING FRAME
Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automati­cally maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET - 3/8” O.D. Tubing. DRAIN OUTLET - 1-1/2” tube outlet for 1-1/2” slip joint connection. (P-Trap not included.)
REFRIGERATION SYSTEM (Model HTHB-OVLSER-I) Hermetically sealed, positive start compressor with lifetime lubrication and built-
in overload protection, efcient capillary sizing, large capacity dryer-strainer,
and self-lubricated fan cools copper/aluminum condenser. System uses R134A refrigerant. Protected by Halsy Taylor’s Limited 5 Year Warranty.
CAPACITIES CHART
GPH Capacity Cooled to
Model
No.
50°F
Ambient Air Temp.
Base
Rate
Capacity
F.L.A. Amps
Shipping
Weight
Rated
Watt
Usage
OVL Fountain With Bottle Filler
Rated for Indoor Use Only
SUGGESTED SPECIFICATIONS
Provides 8.0 gph of 50°F water at 90°F ambient and 80°F inlet water. Unit
shall include bi-level oval fountains with integral bottle lling station construct­ed of stainless steel and ABS plastic. Bottle ller shall include electronic sen-
sor for no-touch activation with automatic 20-second shut-off timer. Shall pro-
vide 1.5 gpm ow rate with laminar ow to minimize splashing. Shall include
anti-microbial protected plastic components to prevent mold and mildew. Foun­tains shall include front pushbutton activation. Shall have oval contoured fountain basins to minimize splashing and standing water and include rounded edges. Each projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. Shall comply with ANSI 117:1 and ADA guidelines for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61 and 372, UL 399 and CAN/CSA 22.2 No. 120.
Optional Accessories (Extra Cost)
Cane Touch Apron (Item #HTOVLAPR)
Access Panel (Item #ACCESS12X38-5)
Each HTHB-OVLSER-I consists of 2 cartons as follows: Fountain, Panel and Misc. Parts; Mounting Frame. Service stop not included. Total shipping weight: 120 lbs.
70°F 80°F 90°F 100°F
HTHB-OVLSER-I
Note: Continued product improvement makes specication subject to change
without notice. See Halsey Taylor website for most current spec Sheet.
9.3 8.3 7.5 6.8 7.5 5 174 390
HALSEY TAYLOR, 2222 Camden Court, OakBrook, IL 60523
halseytaylor.com
SPEC00053 09/2014
Model HTHB-OVLSER-I OVL-II™ Series Bi-Level Wall Mount Refrigerated Fountain Barrier-Free with HydroBoost
(continued)
®
Refer to diagrams for rough-in of plumb­ing. Install mounting frame into wall per the installation instructions. Hang fountain panel over the wall plate assembly. At­tach fountains to wall plate assembly. Water service line and waste line are to be assembled as required. Final check for leaks and cor­rect functions of fountain should be made. (For details see the installation instructions.)
CAUTION - Fountain must be securely bolted to wall.
MOUNTING INSTRUCTIONS:
Job Name: ______________________________
Date: __________________ Qty. ____________
Contact Info (Name, Phone, Email): __________
________________________________________
________________________________________
Approval: _______________________________
NOTE: A service stop (not included) must be installed at
the fountain inlet line.
NOTE: P-Trap (not supplied) to be installed per local building code.
NOTE: For wall support required locations see installation instructions provided with panel and fountains.
WALL LAYOUT
OPTIONAL BRACKET FOR ACCESS PANEL
5/16" SCREWS OR BOLTS
(12 REQ'D - NOT FURNISHED)
FRAME
5/16" HEX NUT
(4 REQ'D - PROVIDED)
P/N 111577343890
BOLT FRAMES TOGETHER
WITH 5/16" X 3/4" (19mm) BOLTS
(4 REQ'D - PROVIDED)
P/N 111577243890
INSTALL (2) SCREWS
(P/N 111008343890) IN FRAME
BEFORE INSTALLING IN OPENING
HOOK RODS (2) P/N 101567443730
OPERATING PRESSURES:
Supply water - 105 psi maximum
Minimum 40 psi supply line pressure required in special circumstances where both sides of bi-level are in use simultaneously to ensure adequate stream height. Use
of water lter in this situation is not recommended.
ELECTRICAL
Hydroboost® station equipped with electric cord and three-prong molded rubber plug for use with 15­amp minimum receptacle. For the cooling unit, a junction box for a (3) wire, 10 amp branch circuit is
provided. Rated at 115 volt, 60 Hz, single phase.
10 1/4"
260mm OPTIONAL FOR ACCESS PANEL
3" 76mm
51 15/16"
1319mm
4 1/2"
114mm
37 1/2" 952mm
Shown with two optional access panels installed
34 5/8" 879mm
20 7/16" 519mm
FINISHED FLOOR
®
9 7/8" 251mm
FRONT VIEW
38 1/2" 978mm
18 11/16" 475mm
Activation Sensor
44 3/4" 1136mm
40" 1016mm
1 1/2" 38mm
34 1/16" 865mm
1 1/2" 38mm
7" 179mm
3/8" O.D. COPPER TUBE
27" 686mm
ADA
REQUIREMENT
SIDE VIEW
17 5/16" 440mm
13 5/16" 338mm
5/8"
16mm
WATER INLET ON
CHILLER. SHUT OFF
VALVE BY OTHERS
ELECTRICAL INLET
1 1/8" 29mm
11" 279mm
12" 305mm
SPACE REQ'D BEHIND STUD WALL
BOTTLER FILLER DRAIN
1-1/4" (32mm) WASTE TUBES FURNISHED
1/4" O.D. COPPER TUBE. COLD WATER OUTLET
8" 203mm
4 1/2" 114mm
28 1/2" 724mm
34 1/2" 876mm
Printed in the U.S.A.