Halsey Taylor HTHBHVR-NF2A Installation Manual

HTHBHVR-NF*A, *2A HTHBHVRBL-NF*A, *2A HTHBHVRBLR-NF*A, *2A
HTHBHVR8-NF*1A, *2A, *3A HTHBHVR8BL-NF*1A, *2A, *3A HTHBHVR8BLR-NF*1A, *2A, *3A
Owners Manual
HTHBHVR8-NF, HTHBHVR8-NF-25, HTHBHVR8-NF-26 Factory Prep
Hydroboost Bottle Filling Station and Cooler
IMPORTANT
THIS IS AN INDOOR APPLICATION ONLY.
Model HTHBHVR8-NF
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON.
Model HTHBHVR8BL-NF
Page 1 98988C (Rev. G - 01/15)
HTHBHVR-NF*A, *2A HTHBHVRBL-NF*A, *2A HTHBHVRBLR-NF*A, *2A
HTHBHVR8-NF*1A, *2A, *3A HTHBHVR8BL-NF*1A, *2A, *3A HTHBHVR8BLR-NF*1A, *2A, *3A
TOOLS REQUIRED
BUT NOT PROVIDED:
SAFETY GLASSES
GLOVES
ELECTRIC DRILL
3/4” WRENCH OR CRECENT WRENCH
UTILITY KNIFE
TAPE MEASURE
PENCIL
CENTER PUNCH
1/2” SOCKET & RATCHET WRENCH
5/32” ALLEN WRENCH
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION AND WATER COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).
HTHBHVR8-NF Bottle Fillers are among the easiest to install on the market today. To insure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference.
Page 298988C (Rev. G - 01/15)
HTHBHVR-NF*A, *2A HTHBHVRBL-NF*A, *2A HTHBHVRBLR-NF*A, *2A
HTHBHVR8-NF*1A, *2A, *3A HTHBHVR8BL-NF*1A, *2A, *3A HTHBHVR8BLR-NF*1A, *2A, *3A
5-1/8"
131mm
18-9/16"
472mm
66mm
2-5/8"
HANGER BRACKET
48"
1219mm
8"
33-1/16"
840mm
ORIFICE
6-1/4"
159mm
1-1/2"
38mm
C
203mm
31-15/16"
811mm
RIM HEIGHT
HEIGHT
6-3/4"
171mm
12-5/16"
312mm
27"
686mm
*
1298mm
51-1/8"
7"
HTHBHVR8-NF
178mm
16-5/16"
414mm
7"
178mm
MOUNTING
5/16"
8mm
O
HOLES (3 PL)
2-9/16"
185mm
E
4-9/16"
18-1/2"
470mm
1-1/4"
32mm
1-1/4"
32mm
OBROUND HOLE (5 PL)
1/4" X 1/2" (6mm X 13mm)
116mm
E
49-1/2"
1257mm
7-1/4"
2-1/2"
11/16"
18mm
D
B
25"
635mm
65mm
F
63mm
A
31"
788mm
13-7/8"
352mm
89mm
3-1/2"
114mm
4-1/2"
2-7/16"
63mm
10"
254mm
FINISHED FLOOR
5"
127mm
* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
18-3/8"
467mm
21-3/8"
543mm
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2” (38mm)
OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN.
C = 1-1/4” TRAP NOT FURNISHED.
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED.
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO WALL.
F = 7/16” BOLT HOLES FOR FASTENING UNITS TO WALL.
Single Rough-In
Fig. 1
Page 3 98988C (Rev. G - 01/15)