Satisfying Thirsts Since 1912
Model HTHB-HVRGRN8-WF
Filtered Single HVR Green Cooler with
Hydroboost® Bottle Filler
MODEL: HTHB-HVRGRN8-WF
GENERAL
Complete water station including HydroBoost® bottle lling station and
HVR Green water cooler. GreenSpec® Listed, energy and water efcient
single water cooler model. Self-contained, wall-mounted, electric, refrigerated
model. One-piece chrome-plated vandal-resistant water conservation bubbler
with integral hood. Automatic stream height regulator is located inside unit to
prevent tampering. Includes self-closing, light touch front pushbutton
actuation. Type 300 series stainless steel cooler top, with satin nish resists
stains. Anti-splash ridge reduces splatter. Contoured to insure proper
drainage.
HYDROBOOST® BOTTLE FILLING STATION
Sensor-activated enhanced with user interface graphics. Quick ll rate is
1.1 gallons per minute. Laminar ow provides a clean ll with minimal splash
and easy maintenance. Equipped with an automatic 20-second shut-off timer.
SILVER ION ANTI-MICROBIAL PROTECTION
Key plastic components are integrated with silver ion
anti-microbial protection to inhibit growth of mold and mildew.
GREEN COUNTER™
Visually displays count of plastic bottles saved from landlls. (Based on 20 oz.
bottles for refrigerated models)
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or
twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists
corrosion and liming. A constant stream height is automatically maintained under
line pressures that vary from 20 to 105 psi.
WATER INLET - 3/8” O.D. Tubing. DRAIN OUTLET - 1-1/4” tube outlet for
1-1/4” slip joint connection. Trap and service stop not included.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication
and built-in overload protection, efcient capillary sizing, large capacity
dryer-strainer and self-lubricated fan cools copper/ aluminum condenser.
System uses R-134A refrigerant. Protected by Halsey Taylor’s
Limited 5 Year Warranty.
LEAD REDUCTION FILTER WITH FILTER LIFE INDICATOR
Equipped with the HWF3000 Watersentry® Plus Filter. Features
Quick-Disconnect, 1/4 turn installation and automatic inlet shut-off valve
that closes when lter is removed. High grade lter is made with
activated carbon and patented ATS lead-removal media.
Certied to NSF/ANSI 42 for Chlorine-Class 1, Particulate-Class 1 and
Taste and Odor and NSF/ANSI 53 for Lead Reduction. Filter is rated for
3,000 gallon capacity. Green, yellow and red LEDs visually indicate when
lter maintenance is required.
Replacement Filters: Available as Singles and Multi-Packs.
Order part numbers:
• 55898C (single)
• 55898C_3PK (three pack)
• 55898C_12PK (twelve pack)
• 55898C_24PK (twenty-four pack)
• 55898C_48PK (forty-eight pack)
HVR Green Cooler
with Bottle Filler and Filter
*Rated for Indoor Use Only
Model
HTHB-HVRGRN8-WF
SUGGESTED SPECIFICATION
Unit shall include a single water cooler with a bottle lling station.
Units shall have a high-efciency refrigeration system and deliver 8
gph of 50°F drinking water at 90°F ambient air and 80°F inlet water.
Lower unit shall have mechanically activated pushbar activation. Bottle
ller shall include electronic sensor for no-touch activation with
automatic 20-second shut-off timer. Shall include a Green Counter™
displaying the count of plastic bottles saved from the landll. Shall
include WaterSentry® Plus 3000-gallon capacity lter, certied to
NSF/ANSI 42 for Chlorine-Class 1, Particulate-Class 1 and Taste and Odor
and NSF/ANSI 53 for lead reduction, with LED visual lter monitor to
indicate when lter maintenance Shall provide 1.1 gpm with laminar ow
to minimize splashing. Shall include anti-microbial protected plastic
components to prevent mold and mildew. Cooler shall have stainless
steel basin with anti-splash ridge and removeable drain strainer. Shall
have front and side pushbar activation with raised letters. Shall
comply with ADA guidelines for visual and motion disabilities. The
manufacturer shall certify the unit to meet the requirements of
NSF/ANSI 61 and 372, UL 399 and CAN/CSA 22.2 No 120.
CAPACITIES CHART
Model
No.
GPH Capacity Cooled to 50°F** Base
Ambient Air Temp
70°F 80°F 90°F
t
100°F
Rate
Cap.
F.L.
Amps
Shipping
Weight
lb.
Rated
Watt
Usage
HTHB-HVRGRN8-WF 9.7 8.8 8.0 7.2 8.0 3.8 89 260
NOTE: Continued product improvement makes specication sheets subject to change without notice.
** With projector service and tap water at 80°F
t
UL 399 and ASHRAE (previously ARI 1010) compliant
halseytaylor.com
HALSEY TAYLOR, 2222 Camden Court, OakBrook, IL 60523
SPEC00210 09/2014
Model HTHB-HVRGRN8-WF
Filtered Single HVR Green Cooler with
Hydroboost® Bottle Filler
OPERATING PRESSURES
Supply water - 105 psi maximum
Minimum 40 psi supply line pressure required
in special circumstances where both sides of
bi-level are in use simultaneously to ensure
adequate stream height. Use of water lter in
this situation is not recommended.
FRONT VIEW SIDE VIEW
7/16"
O
11mm
MOUNTING HOLES
(6)
5 3/4"
21 3/8"
543mm
146mm
1 3/8"
35mm
18 3/8"
467mm
E
B
D
A
52 1/16"
1323mm
ACTIVATION
SENSOR
39 1/16"
991mm
5/16" (8mm) DIA. (5 HOLES)
31"
787mm
25"
635mm
NOTE: A service stop (not included) must be installed at
the water inlet line.
NOTE: P-Trap (not supplied) to be installed per local
building code.
17 7/8"
454mm
7"
178mm
5"
127mm
C
L
7"
178mm
11/16"
18mm
2 7/16"
63mm
4 1/2"
114mm
10"
254mm
2 1/2"
64mm
3 1/2"
89mm
4 9/16"
116mm
F
13 7/8"
352mm
5 3/4"
146mm
1 3/8"
35mm
E
7 1/4"
185mm
2 9/16"
65mm
15"
381mm
3 3/16"
82mm
FINISHED FLOOR
32 15/16"
837mm
ORIFICE
HEIGHT
ELECTRICAL
Hydroboost® station equipped with electric cord
and three-prong molded rubber plug for use with
15-amp minimum receptacle. Rated at 115 volt,
60 Hz, single phase.
3 9/16"
90mm
18 1/2"
471mm
2 5/8"
67mm
31 13/16"
808mm
RIM HEIGHT
REQUIREMENTS
27"
686mm
ADA
HANGER BRACKET
C
6 1/4"
159mm
12 5/16"
313mm
1 1/2"
38mm
6 3/4"
172mm
18 7/8"
479mm
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply Location. Shut-off valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/4” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from
cabinet louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
**New Installations Must Use Ground Fault Circuit Interrupter (GFCI).
®
Page 2
Job Name: ____________________________________
Model: _____________________________ Qty. ______
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
Printed in the U.S.A.