Complete water station including HydroBoost® bottle lling station and HVR Green Single water cooler. GreenSpec® Listed, energy and water efcient single water cooler model. Self-contained, wall-mounted, electric, refrigerated model. One-piece chrome-plated vandal-resistant water conservation bubbler with integral hood. Automatic stream height regulator is located inside unit to prevent tampering. Includes self-closing, light touch front pushbutton actuation. Type
300 series stainless steel cooler top, with satin nish resists
stains. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
HYDROBOOST® BOTTLE FILLING STATION
Sensor-activated enhanced with user interface graphics. Quick
ll rate is 1.1 gallons per minute. Laminar ow provides a clean ll with minimal splash and easy maintenance. Equipped with an
automatic 20-second shut-off timer.
SILVER ION ANTI-MICROBIAL PROTECTION
Key plastic components are integrated with silver ion anti-microbial protection to inhibit growth of mold and mildew.
GREEN COUNTER™
Visually displays count of plastic bottles saved from the landlls.
(Based on 20 oz. bottles for refrigerated models)
HVR Green Cooler
with Bottle Filler
*Rated for Indoor Use Only
Model HTHB-HVRGRN8-NF
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require
grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
WATER INLET - 3/8” O.D. Tubing. DRAIN OUTLET - 1-1/4” tube outlet for 1-1/4” slip joint connection. Trap and service stop
not included.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime
lubrication and built-in overload protection, efcient capillary
sizing, large capacity dryer-strainer and self-lubricated fan cools copper/ aluminum condenser. System uses R-134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
CAPACITIES CHART
Model No.
HTHB-HVRGRN8-NF 9.7 8.8 8.0 7.2 8.0 3.8 89 260
NOTE: Continued product improvement makes specication sheets subject to change without notice.
** With projector service and tap water at 80°F
t
UL 399 and ASHRAE (previously ARI 1010) compliant
GPH Capacity Cooled to 50°F** Base
Ambient Air Temp
70°F 80°F 90°F
t
100°F
SUGGESTED SPECIFICATION
Unit shall include a single water cooler with a bottle lling station. Units shall have a high-efciency refrigeration
system and deliver 8 GPH of 50°F drinking water at 90°F ambient air and 80°F inlet water. Lower unit shall have
mechanically activated pushbutton activation. Bottle ller shall
include electronic sensor for no-touch activation with automatic 20-second shut-off timer. Shall include a Green Counter™ displaying the count of plastic bottles
saved from the landll. Shall provide 1.1 gpm with laminar ow to minimize splashing. Shall include anti-microbial
protected plastic components to prevent mold and mildew. Cooler shall have stainless steel cabinet and basin. Cooler shall include removable drain strainer. Shall comply with ADA guidelines for visual and motion disabilities. The
manufacturer shall certify the unit to meet the requirements of
NSF/ANSI 61 and 372, UL 399 and CAN/CSA 22.2 No. 120.
Rate Cap.
F.L.
Amps
Shipping
Weight
lb.
Rated
Watt
Usage
HALSEY TAYLOR, 2222 Camden Court, OakBrook, IL 60523
halseytaylor.com
SPEC00219 09/2014
Model HTHB-HVRGRN8-NF Single HVR Green Cooler with Hydroboost® Bottle Filler
1/4” O.D. TUBE
WATER INLET
TO COOLER
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
52 1/16" 1323mm
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
B CA
ACTIVATION SENSOR
39 1/16" 991mm
31" 787mm
SERVICE STOP
(NOT FURNISHED)
TUBE IS SECURED
TUBE IS SECURED
IN POSITION
IN POSITION
7/16"
O
11mm
MOUNTING HOLES
(6)
5/16" (8mm) DIA. (5 HOLES)
25" 635mm
21 3/8" 543mm
BUILDING WATER
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
5 3/4" 146mm
1 3/8" 35mm
E
18 3/8" 467mm
INLET
NOTE: A service stop (not included) must be installed at the water inlet line.
NOTE: P-Trap (not supplied) to be installed per local building code.
Hydroboost® station equipped with electric cord and three-prong molded rubber plug for use with 15-amp minimum receptacle. Rated at 115 volt, 60 Hz, single phase.
OPERATING PRESSURES
Supply water - 105 psi maximum
Minimum 40 psi supply line pressure required
in special circumstances where both sides of bi-level are in use simultaneously to ensure
adequate stream height. Use of water lter in
this situation is not recommended.
FRONT VIEW SIDE VIEW
17 7/8"
ELECTRICAL
454mm
7" 178mm
B
D
A
5" 127mm
C
L
7" 178mm
11/16" 18mm
2 7/16" 63mm
4 1/2" 114mm
10" 254mm
2 1/2" 64mm
3 1/2" 89mm
4 9/16" 116mm
F
13 7/8" 352mm
5 3/4" 146mm
1 3/8" 35mm
E
7 1/4" 185mm
2 9/16" 65mm
15" 381mm
3 3/16" 82mm
FINISHED FLOOR
32 15/16" 837mm
ORIFICE HEIGHT
2 5/8" 67mm
31 13/16" 808mm
RIM HEIGHT
REQUIREMENTS
27"
686mm
ADA
3 9/16" 90mm
18 1/2" 471mm
HANGER BRACKET
C
6 1/4" 159mm
12 5/16" 313mm
1 1/2" 38mm
6 3/4" 172mm
18 7/8" 479mm
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND: A = Recommended Water Supply Location. Shut-off valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall. B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain. Drain stub 2” (51mm) out from wall. C = 1-1/4” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall. F = 7/16” (11mm) Bolt Holes for fastening to wall. **New Installations Must Use Ground Fault Circuit Interrupter (GFCI).
®
Page 2
Job Name: ____________________________________
Model: _____________________________ Qty. ______
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
Printed in the U.S.A.
Loading...