Halsey Taylor HTHB-HVRGRN8BL-WF User Manual

Satisfying Thirsts Since 1912
Model HTHB-HVRGRN8BL-WF
Filtered Bi-Level HVR Green Cooler with
Hydroboost® Bottle Filler
MODEL: HTHB-HVRGRN8BL-WF
GENERAL
Complete water station including HydroBoost® bottle lling station and HVRGRN8BL water cooler(s). GreenSpec®
Listed, energy and water efcient, bi-level water cooler. Self-contained, wall-mounted, electric refrigerated model. One-piece chrome-plated vandal-resistant water conservation
bubbler with integral hood. Automatic stream height regulator is
located inside unit to prevent tampering. Includes self-closing,
light touch front pushbutton actuation. Type 300 series stainless
steel cooler top, with satin nish resists stains. Anti-splash ridge
reduces splatter. Contoured to insure proper drainage.
HYDROBOOST® BOTTLE FILLING STATION
Sensor-activated enhanced with user interface graphics. Quick ll rate
is 1.1 gallons per minute on refrigerated model and 1.5 gallons per
minute on non-refrigerated model. Laminar ow provides a clean ll
with minimal splash and easy maintenance. Equipped with an
automatic 20-second shut-off timer.
SILVER ION ANTI-MICROBIAL PROTECTION
Key plastic components are integrated with silver ion anti-microbial protection to inhibit growth of mold and mildew.
GREEN COUNTER™
Visually displays count of plastic bottles saved from landlls. (Based on
20 oz. bottles for refrigerated models)
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or
twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit
resists corrosion and liming. A constant stream height is automatically
maintained under line pressures that vary from 20 to 105 psi.
WATER INLET - 3/8” O.D. Tubing. DRAIN OUTLET - 1-1/2” tube outlet for 1-1/2” slip joint connection. Trap and service stop not included.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efcient capillary sizing, large capacity dryer-strainer and self-lubricated fan cools copper/ aluminum condenser. System uses R-134A refrigerant. Protected by Halsey Taylor’s
Limited 5 Year Warranty.
LEAD REDUCTION FILTER WITH FILTER LIFE INDICATOR
Equipped with the HWF3000 Watersentry® Plus Filter. Features
Quick-Disconnect, 1/4 turn installation and automatic inlet shut-off valve that closes when lter is removed. High grade lter is made with activated carbon and patented ATS lead-removal media. Certied to NSF/ANSI 42 for Chlorine-Class 1, Particulate-Class 1 and
Taste and Odor and NSF/ANSI 53 for Lead Reduction. Filter is rated for
3,000 gallon capacity. Green, yellow and red LEDs visually indicate when lter maintenance is required.
CAPACITIES CHART
HVR Green Coolers
with Bottle Filler and Filter
*Rated for Indoor Use Only
Model
HTHB-HVRGRN8BL-WF
SUGGESTED SPECIFICATION
Unit shall include a bi-level water cooler with a bottle lling station. Units shall have a high-efciency refrigeration system and deliver 8 GPH of 50°F drinking water at 90°F ambient air and 80°F inlet water. Lower units shall have mechanically activated pushbutton activation. Bottle ller shall include electronic sensor for no-touch activation with automatic 20-second shut-off timer. Shall include a Green Counter™ displaying the count of plastic bottles saved from the landll. Shall include the WaterSentry® Plus 3000-gallon lter, certied to NSF/ANSI 42 for Chlorine-Class 1, Particulate-Class 1 and Taste and Odor and NSF/ANSI 53 for Lead Reduction, with LED visual monitor lter to indicate when lter maintenance is required. Shall provide 1.1 gpm with laminar ow to minimize splashing. Shall include anti-microbial protected plastic components to prevent mold and mildew. Cooler shall have stainless steel cabinet and basin. Cooler shall include removable drain strainer. Shall comply with ADA guidelines for visual and motion disabilities. The
manufacturer shall certify the unit to meet the requirements of
NSF/ANSI 61 and 372, UL 399 and CAN/CSA 22.2 No. 120.
Replacement Filters: Available as Singles and Multi-Packs.
Order part numbers:
55898C (single)
55898C_3PK (three)
• 55898C_12PK (twelve)
• 55898C_24PK (twenty-four)
• 55898C_48PK (forty-eight)
Model No.
HTHB-HVRGRN8BL-WF 9.7 8.8 8.0 7.2 8.0 3.8 89 260
NOTE: Continued product improvement makes specication sheets subject to change without notice.
** With projector service and tap water at 80°F
t
UL 399 and ASHRAE (previously ARI 1010) compliant
GPH Capacity Cooled to 50°F** Base
Ambient Air Temp
70°F 80°F 90°F
HALSEY TAYLOR, 2222 Camden Court, OakBrook, IL 60523
t
100°F
halseytaylor.com
Rate Cap.
F.L.
Amps
Shipping
Weight
lb.
Rated
Watt
Usage
SPEC00211 09/2014
Model HTHB-HVRGRN8BL-WF Filtered Bi-Level HVR Green Cooler with Hydroboost® Bottle Filler
OPERATING PRESSURES
Supply water - 105 psi maximum
Minimum 40 psi supply line pressure required in special circumstances where both sides of
bi-level are in use simultaneously to ensure adequate stream height. Use of water lter in
this situation is not recommended.
FRONT VIEW SIDE VIEW
58 9/16" 1488mm
MOUNTING HOLES
ACTIVATION SENSOR
45 9/16" 1157mm
O
37 1/2"
952mm
7/16"
11mm
(6)
15"
381mm
5/16" (8mm) DIA.
6 1/2"
165mm
7 1/4"
185mm
20 3/8" 518mm
5 3/4"
146mm
(10 HOLES)
1 3/8"
35mm
E
F
2 9/16" 65mm
178mm
4 9/16" 116mm
5"
127mm
7"
17 7/8"
454mm
178mm
1 3/8"
35mm
C
L
10"
254mm
FINISHED FLOOR
11/16" 18mm
2 7/16" 63mm
NOTE: A service stop (not included) must be installed at the water inlet line.
NOTE: P-Trap (not supplied) to be installed per local building code.
7"
18 1/16"
459mm
5 3/4"
146mm
5 3/4"
146mm
1 3/8"
1 3/8"
35mm
35mm
C
L
B
6 1/4"
159mm
3 1/2"
89mm
4 1/2"
114mm
5 3/4"
146mm
13 7/8"
352mm
D
E
A
F
18 3/4"
476mm
20 1/8" 511mm
25 1/8"
638mm
39 7/16"
1002mm
ORIFICE HEIGHT
ORIFICE HEIGHT
ELECTRICAL
Hydroboost® station equipped with electric cord
and three-prong molded rubber plug for use with 15-amp minimum receptacle. Rated at 115 volt,
60 Hz, single phase.
3 9/16" 90mm
18 5/8"
472mm
32 15/16"
837mm
2 5/8" 67mm
31 15/16"
811mm
RIM HEIGHT
27"
686mm
ADA
REQURIEMENTS
8"
203mm
105mm
HANGER BRACKET
C
4 1/8"
12 5/16" 313mm
6 3/4"
172mm
18 7/8"
479mm
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply Location. Shut-off valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall. B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/2” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
**New Installations Must Use Ground Fault Circuit Interrupter (GFCI).
®
Page 2
Job Name: ____________________________________
Model: _____________________________ Qty. ______
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
Printed in the U.S.A.
Loading...