Halsey Taylor HTHBHVR8BLR-NF User Manual

Vandal-Resistant
HYDROBOOST
Models:
HTHBHVR8BLR-NF HTHBHVRBLR-NF
GENERAL
Complete water station including HydroBoost™ bottle filling station and HVR water cooler.
HVR WATER COOLER
Self-contained, stainless steel, wall mount single level water cooler. Model HTHBHVR8BLR-NF delivers chilled water; HTHBHVRBLR-NF delivers ambient drinking water. Vandal-resistant one-piece, chrome­plated bubbler with integral hood guard design to prevent tampering, airborne deposits and contamination. Automatic stream height regula­tor is located inside unit to prevent tampering. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. Includes self-closing vandal-resistant pushbutton which does not require grasping or twisting. Type 300 series stainless steel cooler top with satin finish to resist stains and corrosion. Basin includes anti-splash ridge and contoured to insure proper drainage.
Stainless steel design for tamper-resistance. Pushbutton activation enhanced with embossed user graphics. Quick fill rate is 1.1 gallons per minute on chilled model and 1.5 gpm on ambient model. Laminar flow provides a clean fill with minimal splash and easy maintenance. 30-second shut-off timer for water flow. Recessed orifice to prevent cross-contamination.
GREEN COUNTER™
Visually displays count of plastic water bottles saved from the landfills. Protected behind tempered glass.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
REFRIGERATION SYSTEM (Model HTHBHVR8BLR-NF Only)
Unit provides 8GPH of 50
o
F inlet water. Hermetically sealed, positive start compressor
80 with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer and self-lubricated fan cools copper/ aluminum condenser. R-134a refrigerant. Protected by Halsey Taylor’s Limited Warranty.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50
o
F drinking water at 90oF ambient air and
o
F adjustable + 5oF.
HVR Bi-Level Reverse
with Bottle Filler
SUGGESTED SPECIFICATION
Model HTHBHVR8BLR-NF shall deliver 8GPH of
o
50 F drinking water at 90 F ambient air and 80 F inlet water. Model HTHBHVRBLR-NF shall deliver non-chilled drinking water. Shall have stainless steel construction. Shall include vandal-resistant, one-piece bubbler with integral hood. Shall include vandal-resistant pushbutton activation with embossed user graphics. Shall include 30-second auto shut-off for water flow. Shall include Green Counter with tempered glass protective covering. Shall provide 1.1-1.5 gpm with laminar flow for minimal splash and recessed orifice to prevent cross-contamination. Cooler shall have stainless steel basin with anti-splash ridge and removeable drain strainer. Shall comply with ADA standards, UL399, CAN/CSA
22.2 No. 120, NSF/ANSI 61 and NSF/ANSI
oo
372.
Trap and service stop not included.
NOTE: Continued product improvement makes specification sheets subject to change without notice.
halseytaylor.com
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
JOB NAME: ______________________
________________________________
________________________________
ENGINEER/CONTRACTOR NAME:
________________________________
APPROVAL: _____________________
DATE: __________________________
6-2012
HTHBHVR8BLR-NF and HTHBHVRBLR-NF
Bi-Level Reverse HVR Cooler with HydroBoost™ Bottle Filler
(CONTINUED)
49-1/2" 1257mm
18-1/2" 470mm
31" 787mm
6-1/2" 165mm
18-3/4" 476mm
OPERATING PRESSURES
Supply water – 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances when both units are in use simultaneously to ensure adequate flow.
16-5/16" 414mm
7-1/4" 185mm
13-7/8" 352mm
1-1/4" 32mm
E B
F
2-9/16" 65mm
7" 178mm
4-9/16" 116mm
6-1/4" 159mm
1-1/4" 32mm
C
L
11/16" 18mm
7" 178mm
18-1/16" 459mm
5" 127mm
1-3/8" 35mm
5-3/4" 146mm
D
C
L
10" 254mm
2-7/16" 63mm
3-1/2" 89mm
4-1/2" 114mm
1-3/8" 35mm
5-3/4" 146mm
E
A
F
20-3/8" 518mm
31-11/16" 805mm
26-11/16" 678mm
ELECTRICAL
HydroBoost Station equipped with plug-in, 3-wire ground type service cord. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
5-1/8" 131mm
18-9/16"
8" 204mm
C
4-1/8" 105mm
12-5/16" 313mm
472mm
6-3/4" 172mm
51-1/8" 1298mm
48" 1219mm
39-9/16" 1005mm
ORIFICE HEIGHT
33-1/16" 840mm
ORIFICE
HEIGHT
RIM HEIGHT
2-5/8" 66mm
*
31-15/16" 811mm
27" 686mm
FINISHED FLOOR
* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2” (38mm) OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN. C = 1-1/2” TRAP NOT FURNISHED. D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED. E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO WALL. F = 7/16” BOLT HOLES FOR FASTENING UNITS TO WALL.
Printed in the U.S.APage 2
Loading...