Halsey Taylor HTHBHVR8BL User Manual

Filtered
Vandal-Resistant
HYDROBOOST
Models:
HTHBHVR8BL HTHBHVRBL
GENERAL
Complete filtered water station including HydroBoost™ bottle filling station and HVR water cooler.
Self-contained, stainless steel, wall mount single level water cooler. Model HTHBHVR8BL delivers chilled water; HTHBHVRBL delivers ambient drinking water. Vandal-resistant one-piece, chrome-plated bubbler with integral hood guard design to prevent tampering, airborne deposits and contamination. Automatic stream height regula­tor is located inside unit to prevent tampering. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi. Includes self-closing vandal-resistant pushbutton which does not require grasping or twisting. Type 300 series stainless steel cooler top with satin finish to resist stains and corrosion. Basin includes anti-splash ridge and contoured to insure proper drainage.
HYDROBOOST™ BOTTLE FILLING STATION
Stainless steel design for tamper-resistance. Pushbutton activation enhanced with embossed user graphics. Quick fill rate is 1.1 gallons per minute on chilled model and 1.5 gpm on ambient model. Laminar flow provides a clean fill with minimal splash and easy maintenance. 30-second shut-off timer for water flow. Recessed orifice to prevent cross-contamination.
LEAD REDUCTION FILTER WITH FILTER LIFE INDICATOR
Equipped with the HWF3000 WaterSentry Plus 3000 gallon capacity filter. Quick Disconnect, 1/4 turn installation and automatic inlet shutoff valve that closes when filter is removed. High-grade filter is made with activated carbon. Complies with NSF/ANSI 41 for Aesthetic Chlorine, Class I Particulate and Taste and Odor reduction and NSF/ANSI 53 for Lead reduction.
Green, yellow and red LEDs visu maintenance is required. For service replacement, order as: 55898C (single), 55898C_3PK (three), 55898C_12PK (twelve)
55898C_24PK (twenty-four), or 55898C_48PK (forty-eight).
GREEN COUNTER™
Visually displays count of plastic water bottles saved from the landfills. Protected behind tempered glass.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
REFRIGERATION SYSTEM (Model HTHBHVR8BL Only)
Unit provides 8GPH of 50
o
F inlet water. Hermetically sealed, positive start compressor
80 with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer and self-lubricated fan cools copper/ aluminum condenser. R-134a refrigerant. Protected by Halsey Taylor’s Limited Warranty.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50
Trap and service stop not included.
o
F drinking water at 90oF ambient air and
o
F adjustable + 5oF.
®
ally indicate when filter
HVR Bi-Level Cooler
with Bottle Filler
SUGGESTED SPECIFICATION
Model HTHBHVR8BL shall deliver 8GPH of 50 F drinking water at 90 F ambient air and 80 F inlet water. Model HTHBHVRBL shall deliver non-chilled drinking water. Stainless steel construction. Shall include WaterSentry Plus 3000 gallon capacity filter, certified to NSF/ANSI 42 and 53 with LED filter life monitor to indicate when replacement is necessary. Shall include vandal-resistant, one-piece bubbler with integral hood. Shall include vandal-resistant pushbutton activation with embossed user graphics. Shall include 30-second auto shut-off for water flow. Shall include Green Counter with tempered glass protective covering. Shall provide 1.1-1.5 gpm with laminar flow for minimal splash and recessed orifice to prevent cross-contamination. Cooler shall have stainless steel basin with anti-splash ridge and removeable drain strainer. Shall comply with ADA standards, UL399, CAN/CSA
22.2 No. 120, NSF/ANSI 61 and NSF/ANSI
o o
JOB NAME: ______________________
________________________________
________________________________
ENGINEER/CONTRACTOR NAME:
________________________________
APPROVAL: _____________________
DATE: __________________________
o
372.
NOTE: Continued product improvement makes specification sheets subject to change without notice.
halseytaylor.com
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
6-2012
HTHBHVR8BL and HTHBHVRBL
Filtered Bi-Level HVR Cooler with HydroBoost™ Bottle Filler
(CONTINUED)
O
(5 PL)
37-1/2" 952mm
5/16" 8mm
20-3/8" 518mm
1-3/8" 35mm
HOLES
6-1/2" 165mm
7-1/4" 185mm
5" 127mm
OPERATING PRESSURES
Supply water – 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances when both units are in use simultaneously to ensure adequate flow.
16-5/16"
7" 178mm
1-1/4" 32mm
6-1/4" 159mm
414mm
C
L
18-1/2" 470mm
D
3-1/2" 89mm
4-1/2" 114mm
E
F
2-9/16" 65mm
5-3/4" 146mm
4-9/16" 116mm
18-1/16" 459mm
1-3/8" 35mm
5-3/4" 146mm
C
L
11/16" 18mm
2-7/16" 63mm
10" 254mm
FINISHED FLOOR
B
7" 178mm
5/16"
O
8mm
(3 PL)
1-1/4" 32mm
1/4" X 1/2" (6mm X 13mm) OBROUND HOLE (5 PL)
A
E
F
20-1/8" 511mm
18-3/4" 476mm
13-7/8" 352mm
HOLES
25-1/8" 638mm
ELECTRICAL
HydroBoost Station equipped with plug-in, 3-wire ground type service cord. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
18-9/16"
51-1/8" 1298mm
48" 1219mm
39-9/16" 1005mm
ORIFICE HEIGHT
33-1/16" 840mm
ORIFICE
HEIGHT
RIM HEIGHT
31-15/16" 811mm
*
27" 686mm
8" 203mm
4-1/8" 105mm
472mm
2-5/8" 67mm
HANGER
BRACKET
C
12-5/16" 313mm
5-1/8" 131mm
6-3/4" 171mm
* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2” (38mm) OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN. C = 1-1/2” TRAP NOT FURNISHED. D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED. E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO WALL. F = 7/16” BOLT HOLES FOR FASTENING UNITS TO WALL.