Halsey Taylor HTHBHVR8, HTHBHVR8-25, HTHBHVR8-26 Owners Manual

HTHBHVR8-NF*1A, *2A, *3A HTHBHVR-NF*A, *2A HTHBHVR8*1A, *2A, *3A HTHBHVR*A, *2A
Owners Manual
HTHBHVR8, HTHBHVR8-25, HTHBHVR8-26 Factory Prep
HydroBoost® Bottle Filling Station and Cooler
Model HTHBHVR8
Page 1
98986C (Rev. Q - 12/18)
HTHBHVR8-NF*1A, *2A, *3A HTHBHVR-NF*A, *2A HTHBHVR8*1A, *2A, *3A HTHBHVR*A, *2A
TOOLS REQUIRED
BUT NOT PROVIDED:
SAFETY GLASSES
GLOVES
ELECTRIC DRILL
3/4” WRENCH OR CRESCENT WRENCH
UTILITY KNIFE
TAPE MEASURE
PENCIL
CENTER PUNCH
1/2” SOCKET & RATCHET WRENCH
5/32” ALLEN WRENCH
IMPORTANT! INSTALLER PLEASE NOTE
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THAT THE BOTTLE FILLING STATION AND WATER COOLER BE PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI).
HTHBHVR8 Bottle Fillers are among the easiest to install on the market today. To insure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference.
98986C (Rev. Q - 12/18)
Page 2
HTHBHVR8-NF*1A, *2A, *3A HTHBHVR-NF*A, *2A HTHBHVR8*1A, *2A, *3A HTHBHVR*A, *2A
Note: Danger! Electric shock hazard. Disconnect power before servicing unit.
Pictured is unit only without Bottle Filler
Uses HFC-134A refrigerant
10
20
3
7
12
15
See Fig. 8
22
27
See Fig. 7
21
6
21
11
24
8
17, 18
25
See Fig. 7
6
16
1
See Fig. 9
27
21
23
21
19
30
21
9
29
21
27
4, 5
2 2
4
27
Fig. 1
Page 3
98986C (Rev. Q - 12/18)
HTHBHVR8-NF*1A, *2A, *3A HTHBHVR-NF*A, *2A HTHBHVR8*1A, *2A, *3A HTHBHVR*A, *2A
5-1/8"
131mm
18-9/16"
472mm
66mm
2-5/8"
HANGER BRACKET
33-1/16"
840mm
ORIFICE
48"
1219mm
6-1/4"
159mm
1-1/2"
38mm
C
8"
203mm
31-15/16"
811mm
RIM HEIGHT
HEIGHT
6-3/4"
171mm
12-5/16"
312mm
27"
686mm
*
* ADA REQUIREMENT
HTHBHVR8
7"
178mm
16-5/16"
414mm
7"
178mm
MOUNTING
5/16"
8mm
O
HOLES (3 PL)
1298mm
51-1/8"
2-9/16"
185mm
E
4-9/16"
18-1/2"
470mm
1-1/4"
32mm
1-1/4"
32mm
OBROUND HOLE (5 PL)
1/4" X 1/2" (6mm X 13mm)
116mm
E
49-1/2"
7-1/4"
2-1/2"
11/16"
18mm
D
B
25"
635mm
1257mm
65mm
F
63mm
A
13-7/8"
352mm
89mm
3-1/2"
114mm
4-1/2"
63mm
2-7/16"
10"
254mm
FINISHED FLOOR
5"
127mm
18-3/8"
467mm
21-3/8"
543mm
* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDREN’S ADA COOLER
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2” (38mm)
OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN.
C = 1-1/4” TRAP NOT FURNISHED.
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED.
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO WALL.
31"
788mm
F = 7/16” BOLT HOLES FOR FASTENING UNITS TO WALL.
98986C (Rev. Q - 12/18)
Fig. 2
Page 4