Halsey Taylor HTHBHVR User Manual

Filtered
Vandal-Resistant
HYDROBOOST
Models:
HTHBHVR8 HTHBHVR
GENERAL
Complete filtered water station including HydroBoost™ bottle filling station and HVR water cooler.
Self-contained, stainless steel, wall mount single level water cooler. Model HTHBHVR8 delivers chilled water; HTHBHVR delivers ambient drinking water. Vandal-resistant one-piece, chrome-plated bubbler with integral hood guard design to prevent tampering, airborne depos­its and contamination. Automatic stream height regulator is located inside unit to prevent tampering. A constant stream height is automati­cally maintained under line pressures that vary from 20 to 105 psi. Includes self-closing vandal-resistant pushbutton which does not require grasping or twisting. Type 300 series stainless steel cooler top with satin finish to resist stains and corrosion. Basin includes anti-splash ridge and contoured to insure proper drainage.
HYDROBOOST™ BOTTLE FILLING STATION
Stainless steel design for tamper-resistance. Pushbutton activation enhanced with embossed user graphics. Quick fill rate is 1.1 gallons per minute on chilled model and 1.5 gpm on ambient model. Laminar flow provides a clean fill with minimal splash and easy maintenance. 30-second shut-off timer for water flow. Recessed orifice to prevent cross-contamination.
LEAD REDUCTION FILTER WITH FILTER LIFE INDICATOR
Equipped with the HWF3000 WaterSentry Plus 3000 gallon capacity filter. Quick Disconnect, 1/4 turn installation and automatic inlet shutoff valve that closes when filter is removed. High-grade filter is made with activated carbon. Complies with NSF/ANSI 41 for Aesthetic Chlorine, Class I Particulate and Taste and Odor reduction and NSF/ANSI 53 for Lead reduction.
Green, yellow and red LEDs visually indicate when filter maintenance is required. For service replacement, order as: 55898C (single), 55898C_3PK (three), 55898C_12PK (twelve)
55898C_24PK (twenty-four), or 55898C_48PK (forty-eight).
GREEN COUNTER™
Visually displays count of plastic water bottles saved from the landfills. Protected behind tempered glass.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
REFRIGERATION SYSTEM (Model HTHBHVR8 Only)
Unit provides 8GPH of 50
o
F inlet water. Hermetically sealed, positive start compressor
80 with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer and self-lubricated fan cools copper/ aluminum condenser. R-134a refrigerant. Protected by Halsey Taylor’s Limited Warranty.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50
Trap and service stop not included.
o
F drinking water at 90oF ambient air and
o
F adjustable + 5oF.
®
HVR Cooler with
Bottle Filler
SUGGESTED SPECIFICATION
Model HTHBHVR8 shall deliver 8GPH of 50 F drinking water at 90 F ambient air and 80 F inlet water. Model HTHBHVR shall deliver non-chilled drinking water. Stainless steel construction. Shall include WaterSentry Plus 3000 gallon capacity filter, certified to NSF/ANSI 42 and 53 with LED filter life monitor to indicate when replacement is necessary. Shall include vandal­resistant, one-piece bubbler with integral hood. Shall include vandal-resistant pushbutton activa­tion with embossed user graphics. Shall include 30-second auto shut-off for water flow. Shall include Green Counter with tempered glass protective covering. Shall provide 1.1-1.5 gpm with laminar flow for minimal splash and recessed orifice to prevent cross-contamination. Cooler shall have stainless steel basin with anti-splash ridge and removeable drain strainer. Shall comply with ADA standards, UL399, CAN/CSA
22.2 No. 120, NSF/ANSI 61 and NSF/ANSI 372.
o o
JOB NAME: ______________________
________________________________
________________________________
ENGINEER/CONTRACTOR NAME:
________________________________
APPROVAL: _____________________
DATE: __________________________
o
NOTE: Continued product improvement makes specification sheets subject to change without notice.
halseytaylor.com
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
6-2012
HTHBHVR8 and HTHBHVR
g
Filtered Single HVR Cooler with HydroBoost™ Bottle Filler
(CONTINUED)
OPERATING PRESSURES
Supply water – 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances when both units are in use simultaneously to ensure adequate flow.
O
HOLES (3 PL)
1/4" X 1/2" (6mm X 13mm) OBROUND HOLE (5 PL)
49-1/2" 1257mm
25" 635mm
31" 788mm
5/16" 8mm
MOUNTING
21-3/8" 543mm
18-3/8" 467mm
ELECTRICAL
HydroBoost Station equipped with plug-in, 3-wire ground type service cord. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
16-5/16" 414mm
7" 178mm
1-1/4" 32mm
E
B
D
A
5" 127mm
7" 178mm
1-1/4" 32mm
2-7/16" 63mm
3-1/2" 89mm
4-1/2" 114mm
10" 254mm
11/16" 18mm
2-1/2" 63mm
18-1/2" 470mm
4-9/16" 116mm
E
F
13-7/8" 352mm
7-1/4" 185mm
2-9/16" 65mm
51-1/8" 1298mm
48" 1219mm
ORIFICE
HEIGHT
33-1/16" 840mm
RIM HEIGHT
31-15/16" 811mm
*
27" 686mm
18-9/16" 472mm
HANGER BRACKET
2-5/8" 66mm
8" 203mm
C
12-5/16" 312mm
1-1/2" 38mm
5-1/8" 131mm
6-1/4" 159mm
6-3/4" 171mm
FINISHED FLOOR
* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2” (38mm) OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN. C = 1-1/4” TRAP NOT FURNISHED. D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED. E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO WALL. F = 7/16” BOLT HOLES FOR FASTENING UNITS TO WALL.
e 2
Pa
Printed in the U.S.A
Loading...