Filtered
Vandal-Resistant
HYDROBOOST
™
Models:
HTHBHVR8
HTHBHVR
GENERAL
Complete filtered water station including HydroBoost™ bottle filling station
and HVR water cooler.
HVR WATER COOLER
Self-contained, stainless steel, wall mount single level water cooler.
Model HTHBHVR8 delivers chilled water; HTHBHVR delivers ambient
drinking water. Vandal-resistant one-piece, chrome-plated bubbler
with integral hood guard design to prevent tampering, airborne deposits and contamination. Automatic stream height regulator is located
inside unit to prevent tampering. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
Includes self-closing vandal-resistant pushbutton which does not
require grasping or twisting. Type 300 series stainless steel cooler top
with satin finish to resist stains and corrosion. Basin includes
anti-splash ridge and contoured to insure proper drainage.
HYDROBOOST™ BOTTLE FILLING STATION
Stainless steel design for tamper-resistance. Pushbutton activation
enhanced with embossed user graphics. Quick fill rate is 1.1 gallons
per minute on chilled model and 1.5 gpm on ambient model. Laminar
flow provides a clean fill with minimal splash and easy maintenance.
30-second shut-off timer for water flow. Recessed orifice to prevent
cross-contamination.
LEAD REDUCTION FILTER WITH FILTER LIFE INDICATOR
Equipped with the HWF3000 WaterSentry Plus 3000 gallon capacity
filter. Quick Disconnect, 1/4 turn installation and automatic inlet
shutoff valve that closes when filter is removed. High-grade filter is
made with activated carbon. Complies with NSF/ANSI 41 for Aesthetic
Chlorine, Class I Particulate and Taste and Odor reduction and
NSF/ANSI 53 for Lead reduction.
Green, yellow and red LEDs visually indicate when filter
maintenance is required. For service replacement, order as:
55898C (single), 55898C_3PK (three), 55898C_12PK (twelve)
55898C_24PK (twenty-four), or 55898C_48PK (forty-eight).
GREEN COUNTER™
Visually displays count of plastic water bottles saved from the landfills.
Protected behind tempered glass.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns
or larger before they enter the waterway.
REFRIGERATION SYSTEM (Model HTHBHVR8 Only)
Unit provides 8GPH of 50
o
F inlet water. Hermetically sealed, positive start compressor
80
with lifetime lubrication and built-in overload protection, efficient
capillary sizing, large capacity dryer-strainer and self-lubricated fan
cools copper/ aluminum condenser. R-134a refrigerant. Protected
by Halsey Taylor’s Limited Warranty.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage
tank water. Factory set at 50
Trap and service stop not included.
o
F drinking water at 90oF ambient air and
o
F adjustable + 5oF.
®
HVR Cooler with
Bottle Filler
SUGGESTED SPECIFICATION
Model HTHBHVR8 shall deliver 8GPH of 50 F
drinking water at 90 F ambient air and 80 F inlet
water. Model HTHBHVR shall deliver non-chilled
drinking water. Stainless steel construction.
Shall include WaterSentry Plus 3000 gallon
capacity filter, certified to NSF/ANSI 42 and 53
with LED filter life monitor to indicate when
replacement is necessary. Shall include vandalresistant, one-piece bubbler with integral hood.
Shall include vandal-resistant pushbutton activation with embossed user graphics. Shall include
30-second auto shut-off for water flow. Shall
include Green Counter with tempered glass
protective covering. Shall provide 1.1-1.5 gpm
with laminar flow for minimal splash and recessed
orifice to prevent cross-contamination. Cooler
shall have stainless steel basin with anti-splash
ridge and removeable drain strainer. Shall
comply with ADA standards, UL399, CAN/CSA
22.2 No. 120, NSF/ANSI 61 and NSF/ANSI 372.
o o
JOB NAME: ______________________
________________________________
________________________________
ENGINEER/CONTRACTOR NAME:
________________________________
APPROVAL: _____________________
DATE: __________________________
o
NOTE: Continued product improvement makes specification
sheets subject to change without notice.
halseytaylor.com
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
6-2012
HTHBHVR8 and HTHBHVR
Filtered Single HVR Cooler with
HydroBoost™ Bottle Filler
(CONTINUED)
OPERATING PRESSURES
Supply water – 105 psi maximum
Minimum 40 psi supply line pressure required in special
circumstances when both units are in use simultaneously
to ensure adequate flow.
O
HOLES (3 PL)
1/4" X 1/2" (6mm X 13mm)
OBROUND HOLE (5 PL)
49-1/2"
1257mm
25"
635mm
31"
788mm
5/16"
8mm
MOUNTING
21-3/8"
543mm
18-3/8"
467mm
ELECTRICAL
HydroBoost Station equipped with plug-in, 3-wire ground
type service cord. Install 120-volt receptacle, rated at
15-amp minimum, to receive 3-wire parallel blade
grounding type male plug.
16-5/16"
414mm
7"
178mm
1-1/4"
32mm
E
B
D
A
5"
127mm
7"
178mm
1-1/4"
32mm
2-7/16"
63mm
3-1/2"
89mm
4-1/2"
114mm
10"
254mm
11/16"
18mm
2-1/2"
63mm
18-1/2"
470mm
4-9/16"
116mm
E
F
13-7/8"
352mm
7-1/4"
185mm
2-9/16"
65mm
51-1/8"
1298mm
48"
1219mm
ORIFICE
HEIGHT
33-1/16"
840mm
RIM HEIGHT
31-15/16"
811mm
*
27"
686mm
18-9/16"
472mm
HANGER BRACKET
2-5/8"
66mm
8"
203mm
C
12-5/16"
312mm
1-1/2"
38mm
5-1/8"
131mm
6-1/4"
159mm
6-3/4"
171mm
FINISHED FLOOR
* REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2”
(38mm)
OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN.
C = 1-1/4” TRAP NOT FURNISHED.
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED.
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152mm) MIN. CLEARANCE FROM CABINET LOUVER TO
WALL.
F = 7/16” BOLT HOLES FOR FASTENING UNITS TO WALL.
e 2
Pa
Printed in the U.S.A