GENERAL
Complete water station including HydroBoost™ bottle lling station and HAC Green water cooler which exceeds average market energy-efciency performance by 35% per CSA 815-99. Self-contained, high-efciency
refrigerated wall-mount water cooler. Exclusive one-piece, chrome-plated, two-stream Double Bubblerwith non-removeable anti-squirt feature and integral hood. Automatic stream height regulator is located inside unit to prevent tampering. Includes self-closing, light touch front and side pushbar actuation with raised letters for the visually impaired. Type 300 series
stainless steel top, with satin nish resists stains. Anti-splash ridge reduces
splatter. Contoured to insure proper drainage.
HYDROBOOST™ BOTTLE FILLING STATION
Sensor-activated enhanced with user interface graphics. Quick ll rate is
1.1 gallons per minute. Laminar ow provides a clean ll with minimal splash
and easy maintenance. Equipped with an automatic 20-second shut-off timer.
SILVER ION ANTI-MICROBIAL PROTECTION
Key plastic components are integrated with silver ion anti-microbial protection to inhibit growth of mold and mildew.
GREEN COUNTER™
Visually displays count of plastic bottles saved from landlls. (Based on 20 oz.
bottles for refrigerated models)
DOUBLE BUBBLER™
Features an exclusive one-piece, chrome plated two-stream mound-building bubbler with non-removable anti-squirt feature. It’s integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET - 3/8” O.D. Tubing. DRAIN OUTLET - 1-1/2” tube outlet for 1-1/2” slip joint connection. Trap and service stop not included.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication
and built-in overload protection, efcient capillary sizing, large capacity
dryer-strainer and self-lubricated fan cools copper/ aluminum condenser. System uses R-134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
LEAD REDUCTION FILTER WITH FILTER LIFE INDICATOR
Equipped with the HWF3000 Watersentry® Plus Filter. Features Quick-Disconnect, 1/4 turn installation and automatic inlet shut-off valve
that closes when lter is removed. High grade lter is made with
activated carbon and patented ATS lead-removal media.
Certied to NSF/ANSI 42 for Chlorine-Class 1, Particulate-Class 1 and Taste and Odor and NSF/ANSI 53 for Lead Reduction. Filter is rated for
3,000 gallon capacity. Green, yellow and red LEDs visually indicate when
lter maintenance is required.
CAPACITIES CHART
HAC Green Cooler
*Rated for Indoor Use Only
Model HTHB-HACG8BLPV-WF
Cooler panels available in Platinum Vinyl or Stainless Steel.
(additional cost)
SUGGESTED SPECIFICATION
Unit shall include a bi-level water cooler with a bottle lling station. Units shall have a high-efciency refrigeration system and deliver 8 gph of
50°F drinking water at 90°F ambient air and 80°F inlet water. Lower unit
shall have mechanically activated pushbar activation. Bottle ller shall
include electronic sensor for no-touch activation with automatic 20-sec­ond shut-off timer. Shall include a Green Counter™ displaying the count
of plastic bottles saved from the landll. Shall include WaterSentry® Plus 3000-gallon capacity lter, certied to NSF/ANSI 42 for Chlorine-Class 1, Particulate-Class 1 and Taste and Odor and NSF/ANSI 53 for lead reduction, with LED visual lter monitor to indicate when lter maintenance is required. Shall provide 1.1 gpm with laminar ow to minimize splashing.
Shall include anti-microbial protected plastic components to prevent mold and mildew. Cooler shall have stainless steel basin with anti-splash ridge and removeable drain strainer. Shall have front and side pushbar activation with raised letters. Shall comply with ADA guidelines for visual and motion disabilities. The manufacturer shall certify the unit to
meet the requirements of NSF/ANSI 61 and 372, UL 399 and CAN/CSA 22.2 No 120.
Replacement Filters: Available as Singles and Multi-Packs.
Order part numbers:
• 55898C (single)
• 55898C_3PK (three pack)
• 55898C_12PK (twelve pack)
• 55898C_24PK (twenty-four pack)
• 55898C_48PK (forty-eight pack)
Model No.
GPH Capacity Cooled to 50°F** Base
Ambient Air Temp
70°F 80°F 90°F
t
100°F
Rate Cap.
F.L.
Amps
Shipping
Weight
lb.
Rated
Watt
Usage
HTHB-HACG8BL*-WF 9.7 8.8 8.0 7.2 8.0 3.8 89 260
NOTE: Continued product improvement makes specication sheets subject to change without notice.
* Finish indicator: PV for Platinum Vinyl and SS for Stainless Steel cooler panels. ** With projector service and tap water at 80°F
t
UL 399 and ASHRAE (previously ARI 1010) compliant
halseytaylor.com
HALSEY TAYLOR, 2222 Camden Court, OakBrook, IL 60523
SPEC00124 03/2014
Model HTHB-HACG8BLPV-WF and HTHB-HACG8BLSS-WF Filtered Bi-Level HAC Green Cooler with Hydroboost™ Bottle Filler
OPERATING PRESSURES
Supply water - 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances where both sides of bi-level are in use simultaneously to ensure
adequate stream height. Use of water lter in
this situation is not recommended.
FRONT VIEW SIDE VIEW
MOUNTING HOLES
58 9/16"
1488mm
O
37 1/2"
952mm
7/16"
11mm
(6)
15"
381mm
5/16" (8mm) DIA.
6 1/2"
165mm
7 1/4"
185mm
20 3/8" 518mm
5 3/4"
146mm
(10 HOLES)
1 3/8"
35mm
E
F
2 9/16" 65mm
178mm
4 9/16"
116mm
5"
127mm
7"
17 7/8"
454mm
178mm
1 3/8"
35mm
C
L
10"
254mm
FINISHED FLOOR
7"
11/16" 18mm
2 7/16" 63mm
NOTE: A service stop (not included) must be installed at the water inlet line.
NOTE: P-Trap (not supplied) to be installed per local building code.
18 1/16"
459mm
5 3/4"
146mm
3 1/2"
89mm
4 1/2"
114mm
5 3/4"
146mm
13 7/8"
352mm
D
E
A
F
18 3/4"
476mm
20 1/8" 511mm
25 1/8"
638mm
5 3/4"
146mm
1 3/8"
1 3/8"
35mm
35mm
C
L
B
6 1/4"
159mm
39 1/2"
1003mm
ORIFICE HEIGHT
ORIFICE HEIGHT
ELECTRICAL
Hydroboost® station equipped with electric cord and three-prong molded rubber plug for use with 15-amp minimum receptacle. Rated at 115 volt,
60 Hz, single phase.
3 9/16" 90mm
18 5/8"
472mm
33"
838mm
2 5/8" 67mm
31 15/16"
811mm
RIM HEIGHT
27"
686mm
ADA
REQUIREMENT
8"
203mm
105mm
HANGER BRACKET
C
4 1/8"
12 5/16" 313mm
6 3/4"
172mm
18 7/8"
479mm
Page 2
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND: A = Recommended Water Supply Location. Shut-off valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain.
Drain stub 2” (51mm) out from wall. C = 1-1/2” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from
cabinet louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall. **New Installations Must Use Ground Fault Circuit Interrupter (GFCI).
®