Halsey Taylor HTHB-HAC8BL User Manual

Satisfying Thirsts Since 1912
Model HTHB-HAC8BL and HTHB-HACDBL
Bi-Level HAC Cooler with
Hydroboost® Bottle Filler
MODELS:
HTHB-HAC8BL HTHB-HACDBL
GENERAL
Complete water station including HydroBoost® bottle lling station and HAC water cooler(s). Self-contained, wall-mounted bi-level water cooler. Model HTHB-HAC8BL delivers chilled drinking water; model HTHB-HACDBL delivers non-refrigerated drinking water. Exclusive one-piece, chrome-plated two-stream Double Bubbler™ with non-removable anti-squirt feature and integral hood. Automatic stream height regulator is located inside unit to prevent tampering. Includes self-closing, light touch front and side pushbar actuation with raised letters for the visually impaired. Type 300 series
stainless steel cooler top, with satin nish resists stains. Anti-splash ridge
reduces splatter. Contoured to insure proper drainage.
HYDROBOOST® BOTTLE FILLING STATION
Sensor-activated enhanced with user interface graphics. Quick ll
rate is 1.1 gallons per minute on refrigerated model and 1.5 gallon
per minute on non-refrigerated model. Laminar ow provides a clean ll with minimal splash and easy maintenance. Equipped with
an automatic 20-second shut-off timer.
SILVER ION ANTI-MICROBIAL PROTECTION
Key plastic components are integrated with silver ion anti-microbial protection to inhibit growth of mold and mildew.
GREEN COUNTER™
Visually displays count of plastic bottles saved from landlls. (Based
on 20 oz. bottles for refrigerated models)
DOUBLE BUBBLER™
Features an exclusive one-piece, chrome plated two-stream mound-building bubbler with non-removable anti-squirt feature. It’s integral hood insures a satisfying drink of water.
PUSH BAR ACTUATION MECHANISM
Self-closing light-touch push bars on front and sides with raised letters for the visually impaired.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET - 3/8” O.D. Tubing. DRAIN OUTLET - 1-1/2” tube outlet for 1-1/2” slip joint connection. Trap and service stop not
included.
REFRIGERATION SYSTEM (Model HTHB-HAC8BL only)
Hermetically sealed, positive start compressor with lifetime lubrication and
built-in overload protection, efcient capillary sizing, large capacity
dryer-strainer and self-lubricated fan cools copper/ aluminum condenser. System uses R-134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
HAC Cooler with
*Rated for Indoor Use Only
Model HTHB-HAC8BL and HTHB-HACDBL
Cooler panels available in Platinum Vinyl or Stainless Steel. (additional cost)
SUGGESTED SPECIFICATION
Unit shall include a bi-level water cooler with a bottle lling station. Model
HTHB-HAC8 shall deliver 8 gph of 50°F drinking water at 90°F ambient air and 80°F inlet water. Model HTHB-HACD shall deliver non-refrigerated drinking water. Lower units shall have mechanically activated pushbar activation. Bottle Filler shall include electronic sensor for no-touch activation with automatic 20-second shut-off timer. Shall include a Green Counter™ displaying the count of plastic bottles saved from the
landll. Shall provide 1.1-1.5 gpm with laminar ow to minimize
splashing. Shall include anti-microbial protected plastic components to prevent mold and mildew. Cooler shall have stainless steel basin with anti-splash ridge and removable drain strainer. Shall have front and side pushbar activation with raised letters. Shall comply with ADA guidelines for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61 and 372, UL 399 and CAN/CSA 22.2 No. 120.
CAPACITIES CHART
Model No.
HTHB-HAC8BL* 9.7 8.8 8.0 7.2 8.0 3.8 89 260
HTHB-HACDBL* - - - - - 1.0 85 120
NOTE: Continued product improvement makes specication sheets subject to change without notice.
* Finish indicator: PV for Platinum Vinyl and SS for Stainless Steel cooler panels. ** With projector service and tap water at 80°F
t
UL 399 and ASHRAE (previously ARI 1010) compliant
GPH Capacity Cooled to 50°F** Base
Ambient Air Temp
70°F 80°F 90°F
HALSEY TAYLOR, 2222 Camden Court, OakBrook, IL 60523
t
100°F
halseytaylor.com
Rate Cap.
F.L.
Amps
Shipping
Weight
lb.
Rated
Usage
SPEC00206 09/2014
Watt
Model HTHB-HAC8BL and HTHB-HACDBL Bi-Level HAC Cooler with Hydroboost® Bottle Filler
1/4” O.D. TUBE
WATER INLET
TO COOLER
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
TUBE IS SECURED
TUBE IS SECURED
IN POSITION
IN POSITION
B CA
BUILDING WATER
SERVICE STOP
(NOT FURNISHED)
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
FRONT VIEW SIDE VIEW
7/16"
O
11mm
58 9/16" 1488mm
MOUNTING HOLES
ACTIVATION SENSOR
45 9/16" 1157mm
952mm
37 1/2"
(6)
15"
381mm
5/16" (8mm) DIA.
6 1/2"
165mm
7 1/4"
185mm
20 3/8" 518mm
5 3/4"
146mm
(10 HOLES)
1 3/8"
35mm
E
F
2 9/16" 65mm
4 9/16" 116mm
5"
127mm
7"
178mm
INLET
17 7/8"
454mm
7"
178mm
1 3/8"
35mm
C
L
11/16" 18mm
2 7/16" 63mm
10"
254mm
FINISHED FLOOR
NOTE: A service stop (not included) must be installed at the water inlet line.
NOTE: P-Trap (not supplied) to be installed per local building code.
18 1/16"
459mm
5 3/4"
146mm
5 3/4"
146mm
1 3/8"
35mm
35mm
C
L
B
6 1/4"
159mm
1 3/8"
3 1/2"
89mm
4 1/2"
114mm
5 3/4"
146mm
13 7/8"
352mm
D
E
A
F
18 3/4"
476mm
20 1/8" 511mm
25 1/8"
638mm
39 1/2"
1003mm
ORIFICE HEIGHT
ORIFICE HEIGHT
ELECTRICAL
Hydroboos® station equipped with electric cord and three-prong molded rubber plug for use with 15-amp minimum receptacle. Rated at 115 volt, 60 Hz, single phase.
OPERATING PRESSURES
Supply water - 105 psi maximum Minimum 40 psi supply line pressure required in special circumstances where both sides of bi-level are in use simultaneously to ensure
adequate stream height. Use of water lter in
this situation is not recommended.
3 9/16" 90mm
18 5/8"
8"
203mm
472mm
HANGER BRACKET
C
4 1/8"
105mm
12 5/16" 313mm
6 3/4"
172mm
33"
838mm
2 5/8" 67mm
31 15/16"
811mm
RIM HEIGHT
27"
686mm
ADA
REQUIREMENT
18 7/8"
479mm
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND: A = Recommended Water Supply Location. Shut-off valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall. B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain. Drain stub 2” (51mm) out from wall. C = 1-1/2” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall. F = 7/16” (11mm) Bolt Holes for fastening to wall. **New Installations Must Use Ground Fault Circuit Interrupter (GFCI).
®
Page 2
Job Name: ____________________________________
Model: _____________________________ Qty. ______
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
Printed in the U.S.A.
Loading...