Satisfying Thirsts Since 1912
Model HTHB-HAC8 and HTHB-HACD
Single HAC Cooler with
Hydroboost® Bottle Filler
MODELS:
HTHB-HAC8
HTHB-HACD
GENERAL
Complete water station including HydroBoost® bottle lling station and
HAC water cooler. Self-contained, wall-mounted water cooler. Model
HTHB-HAC8 delivers chilled drinking water; model HTHB-HACD delivers
non-refrigerated drinking water. Exclusive one-piece, chrome-plated
two-stream Double Bubbler™ with non-removable anti-squirt feature and
integral hood. Automatic stream height regulator is located inside unit to
prevent tampering. Includes self-closing, light touch front and side pushbar
actuation with raised letters for the visually impaired. Type 300 series
stainless steel cooler top, with satin nish resists stains. Anti-splash ridge
reduces splatter. Contoured to insure proper drainage.
HYDROBOOST® BOTTLE FILLING STATION
Sensor-activated enhanced with user interface graphics. Quick ll
rate is 1.1 gallons per minute on refrigerated model and 1.5 gallon
per minute on non-refrigerated model. Laminar ow provides a
clean ll with minimal splash and easy maintenance. Equipped with
an automatic 20-second shut-off timer.
SILVER ION ANTI-MICROBIAL PROTECTION
Key plastic components are integrated with silver ion anti-microbial
protection to inhibit growth of mold and mildew.
GREEN COUNTER™
Visually displays count of plastic bottles saved from landlls. (Based
on 20 oz. bottles for refrigerated models)
DOUBLE BUBBLER™
Features an exclusive one-piece, chrome plated two-stream
mound-building bubbler with non-removable anti-squirt feature. It’s
integral hood insures a satisfying drink of water.
PUSH BAR ACTUATION MECHANISM
Self-closing light-touch push bars on front and sides with raised letters for the
visually impaired.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering.
Unit resists corrosion and liming. A constant stream height is
automatically maintained under line pressures that vary from 20 to
105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger
before they enter the waterway.
WATER INLET - 3/8” O.D. Tubing. DRAIN OUTLET - 1-1/4”
tube outlet for 1-1/4” slip joint connection. Trap and service stop not
included.
REFRIGERATION SYSTEM (Model HTHB-HAC8 only)
Hermetically sealed, positive start compressor with lifetime lubrication and
built-in overload protection, efcient capillary sizing, large capacity
dryer-strainer and self-lubricated fan cools copper/ aluminum condenser.
System uses R-134A refrigerant. Protected by Halsey Taylor’s
Limited 5 Year Warranty.
HAC Cooler with
Bottle Filler
*Rated for Indoor Use Only
Models
HTHB-HAC8 and
HTHB-HACD
Cooler panels available in Platinum Vinyl or Stainless Steel.
(additional cost)
SUGGESTED SPECIFICATION
Unit shall include a single water cooler with a bottle lling station. Model
HTHB-HAC8 shall deliver 8 gph of 50°F drinking water at 90°F ambient air
and 80°F inlet water. Model HTHB-HACD shall deliver non-refrigerated
drinking water. Lower Unit shall have mechanically activated pushbar
activation. Bottle Filler shall include electronic sensor for no-touch
activation with automatic 20-second shut-off timer. Shall include a
Green Counter™ displaying the count of plastic bottles saved from the
landll. Shall provide 1.1-1.5 gpm with laminar ow to minimize
splashing. Shall include anti-microbial protected plastic components to
prevent mold and mildew. Cooler shall have stainless steel basin with
anti-splash ridge and removable drain strainer. Shall have front and
side pushbar activation with raised letters. Shall comply with ADA
guidelines for visual and motion disabilities. The manufacturer shall certify
the unit to meet the requirements of NSF/ANSI 61 and 372, UL 399 and
CAN/CSA 22.2 No. 120.
CAPACITIES CHART
Model
No.
HTHB-HAC8* 9.7 8.8 8.0 7.2 8.0 3.8 89 260
HTHB-HACD* - - - - - 1.0 85 120
NOTE: Continued product improvement makes specication sheets subject to change without notice.
* Finish indicator: PV for Platinum Vinyl and SS for Stainless Steel cooler panels.
** With projector service and tap water at 80°F
t
UL 399 and ASHRAE (previously ARI 1010) compliant
GPH Capacity Cooled to 50°F** Base
Ambient Air Temp
70°F 80°F 90°F
HALSEY TAYLOR, 2222 Camden Court, OakBrook, IL 60523
t
100°F
halseytaylor.com
Rate
Cap.
F.L.
Amps
Shipping
Weight
lb.
SPEC00205 09/2014
Rated
Watt
Usage
Model HTHB-HAC8 and HTHB-HACD
Single HAC Cooler with
Hydroboost® Bottle Filler
1/4” O.D. TUBE
WATER INLET
TO COOLER
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
52 1/16"
1323mm
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
TUBE IS SECURED
TUBE IS SECURED
IN POSITION
IN POSITION
B CA
ACTIVATION
SENSOR
5/16" (8mm) DIA. (5 HOLES)
39 1/16"
991mm
31"
787mm
635mm
SERVICE STOP
(NOT FURNISHED)
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
7/16"
O
11mm
MOUNTING HOLES
(6)
25"
21 3/8"
543mm
BUILDING WATER
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
RELEASE TUBE
RELEASE TUBE
5 3/4"
146mm
1 3/8"
35mm
E
18 3/8"
467mm
INLET
NOTE: A service stop (not included) must be installed at
the water inlet line.
NOTE: P-Trap (not supplied) to be installed per local
building code.
Hydroboost® station equipped with electric cord
and three-prong molded rubber plug for use with
15-amp minimum receptacle. Rated at 115 volt,
60 Hz, single phase.
OPERATING PRESSURES
Supply water - 105 psi maximum
Minimum 40 psi supply line pressure required
in special circumstances where both sides of
bi-level are in use simultaneously to ensure
adequate stream height. Use of water lter in
this situation is not recommended.
FRONT VIEW SIDE VIEW
17 7/8"
ELECTRICAL
454mm
7"
178mm
B
D
A
5"
127mm
C
L
178mm
11/16"
18mm
2 7/16"
63mm
114mm
10"
254mm
7"
2 1/2"
64mm
4 1/2"
3 1/2"
89mm
4 9/16"
116mm
F
13 7/8"
352mm
1 3/8"
35mm
E
185mm
2 9/16"
65mm
5 3/4"
146mm
7 1/4"
15"
381mm
3 3/16"
82mm
FINISHED FLOOR
33"
838mm
ORIFICE
HEIGHT
31 13/16"
808mm
RIM
HEIGHT
2 5/8"
67mm
27"
686mm
ADA
REQUIREMENT
8"
203mm
159mm
6 1/4"
3 9/16"
90mm
18 1/2"
471mm
HANGER BRACKET
C
12 5/16"
313mm
1 1/2"
38mm
172mm
6 3/4"
18 7/8"
479mm
REDUCE HEIGHT BY 3” FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply Location. Shut-off valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/4” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from
cabinet louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
**New Installations Must Use Ground Fault Circuit Interrupter (GFCI).
®
Page 2
Job Name: ____________________________________
Model: _____________________________ Qty. ______
Contact: ______________________________________
Approval Signature: _____________________________
Notes: