Halsey Taylor HTER-Q User Manual

This water cooler is certified to
NSF/ANSI 61.
GENERAL
Modular, electric refrigerated, wall-mounted water cooler designed to be easily accessible to physically challenged individuals. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act. Unit is certified to NSF/ANSI 61 and meets requirements of the Safe Drinking Water Act. Unit provides 50° F water at 80° F inlet water and 90° F ambient.
FOUNTAIN
Face-mounted, one-piece, non-corrosive stainless steel cooler top, number 300 series with satin finish and contour-formed basin.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSH BAR ACTUATION MECHANISM
Self closing, light-touch push bar with raised letters for the visually impaired.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor with lifetime lubrication and built-in overload protection, efficient capillary sizing, large capacity dryer-strainer, and fan cooled copper/aluminum condenser with self-lubricated bearing. System uses R134A refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty.
MOUNTING FRAME
Mounting frame is manufactured of corrosion resistant, galvanized steel. Open construction designed for ease of installation. Mounting frame can be shipped in advance for rough-in installation.
PANELS
Constructed of stainless steel, number 300 series with satin finish. Removable lower panel providing access to plumbing and refrigeration system. Panels overlap wall opening
1
/
2"
.
SUGGESTED SPECIFICATIONS
Shall deliver 7.5 GPH of 50° F water at 90° F ambient and 80° F inlet water. Fountain shall include push bar valve on front, contour-formed basin to eliminate splashing and standing water, and rounded corners and edges. Bubbler shall be chrome plated, two-stream, mound­building type. Cooling unit shall have a high efficiency positive start compressor using R134A, with pressurized counterflow cooling evaporator/chiller. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement makes specifications subject to change without notice. See Halsey Taylor website for most current spec sheet.
Standard finish is Stainless Steel
Optional Accessories (extra cost)
Easy-Flex™Bubbler
Water Filter
Vandal Resistant Kit
Each HTER-Q consists of 3 cartons as follows:
Mounting Frame Cooling Unit-SJ8 Fountain, Panels & Misc. Parts
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
A33 / 1-2005
MODEL:■HTER-Q
Barrier-Free Cooler
Classic™Series
www.halseytaylor.com
HT BARRIER-FREE SERIES
Model GPH Capacity Base F.L. Shipping Rated No. Cooled to 50° F* Rate Amps Weight Watt
Ambient Air Temp
Cap. lb. Usage
70°F 80°F 90°F†100°F
HTER-Q 9.3 8.3 7.5 6.8 7.5 3.5 99 325
* With projector service and tap water at 80° F
For additional specification of the cooling unit, see specification sheet for Model SJ8 Remote in this catalog.
UL listed and complies with ARI Standard 1010
Trap and service stop not included
Halsey Taylor Barrier-Free Drinking Fountains and Water Coolers conform to The Americans with Disabilities Act and American National Standards Institute Specifications.
Printed in the U.S.A.
Barrier-Free Cooler
(CONTINUED)
WALL OPENING
IMPORTANT: It is necessary to create a wall opening 18
3
/4
" W x 37
3
/4
" H and 4
1
/
2
" above the
floor line.
MOUNTING INSTRUCTIONS
Refer to rough-in for location of plumbing and electrical sources. The support frame is to be installed first. The shelf for the water chiller should be assembled to the wall frame, and then place chiller into position. Hang upper fountain panel to hanger on frame. Fountain is to be attached to panel and wall frame. Water service line, waste line and electrical is assembled as required. The bottom panel is attached last, after a final check for leaks and correct functions of fountains and chiller. (For details see the installation instructions.)
Installation requires trap to be installed in wall. Trap and service stop not included.
OPERATING PRESSURES:
Supply water - 105 psi maximum
ELECTRICAL DATA
Requires (3) wire 10 AMP branch circuit. Standard 120 volt, 60 HZ, single phase.
Important: For recommended wall support see installation instructions provided with fountain.
FRONT VIEW
TOP VIEW
SIDE VIEW
27" (686mm) for adult ADA. Adjust other measurements accordingly.
LEGEND:
A = 3/8" O.D. TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS B = 1-1/4" O.D. WASTE TUBE (ELBOW & TRAP NOT PROVIDED) C = ELECTRICAL INLET
Loading...