Halsey Taylor HTE FR User Manual

This fountain is certified to
NSF/ANSI 61.
GENERAL
Face-mounted fountain, one-piece, non-corrosive stainless steel number 300 series with brushed satin finish. Contour­formed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Designed to be easily accessible to both physically challenged and able-bodied individuals. Ideally suited for installation in public areas. Model meets state and federal requirements as defined by the Americans with Disabilities Act.
FREEZE-RESISTANT VALVE SYSTEM
Freeze-resistant system features box that installs behind non-freezing wall for housing water connection from the stop to the strainer.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self-closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/4" waste outlet located in freeze-resistant valve system.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front, contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. Fountain shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice. See Halsey Taylor website for most current spec sheet.
Standard Finish is Stainless Steel
Optional Accessories (extra cost)
Vandal-Resistant Kit
Each HTEFR consists of 2 cartons of the following:
Fountain and Misc. Parts Freeze-Resistant Valve System
Service stop not included.
Copper tube to water supply connection not furnished
Shipping weight: 36 lbs.
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
B14 / 1-2005
MODEL: ■HTE FR
Barrier-Free Fountain
Freeze-Resistant
Classic
Series
www.halseytaylor.com
Halsey Taylor Barrier-Free Drinking Fountains and Water Coolers conform to The Americans with Disabilities Act and American National Standards Institute Specifications.
Printed in the U.S.A.
Classic™Series Freeze-Resistant Barrier-Free Fountain
(CONTINUED)
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of freeze-resistant system and plumbing. For wall support required locations see installation instructions provided with fountain. Bolt fountain securely to wall per installation instructions. Water supply and water line are to be assembled as required. Final check for leaks and correct functions of fountain should be made. (See installation instructions for full details.)
Freeze resistant box must be installed on interior non-freezing wall.
CAUTION – Fountain must be securely
bolted to wall.
OPERATING PRESSURES:
Supply water - 105 psi maximum
FRONT VIEW / WALL LAYOUT
SIDE VIEW
LEGEND: A = 7/8" DIA. (22mm) HOLE FOR WATER INLET B = 1-3/4" DIA. (44mm) HOLE FOR WASTE LINE
(ELBOW AND TRAP PROVIDED)
NOTE: A service supply stop (not included) must be
installed at the fountain inlet line.
*ADA Requirement