Halsey Taylor HT-EBP-FR Installation Manual

HT-SBP-FR, HT-EBP-FR, HT-SEBP-FR
Halsey Taylor Owners Manual
Models: HT-SBP-FR HT-EBP-FR HT-SEBP-FR
Freeze Resistant Fountains
Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUC­TIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLI­ANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference. This Freeze Resistant Fountain is shipped in two separate cartons. The second carton contains the Freeze Resistant Package that is installed on an interior heated wall. Refer to the Freeze Resistant Package for the rough-in dimensions for installation.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELEC­TROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
1/4" O.D. TUBE WATER INLET TO COOLER
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY
NOTE: WATER FLOW
DIRECTION
BUILDING WATER IN LET
SERVICE STOP (NOT FURNISHED)
FIG. 1
PAGE 1
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
FIG. 2
TUBE IS
SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
97642C (Rev. C - 11/01)
HT-SBP-FR, HT-EBP-FR, HT-SEBP-FR
FINISHED FLOOR
HT - EBP - FR ROUGH-IN
FIG. 3
LEGEND
A = 1 3/4" DIA. (44mm) HOLE FOR WASTE LINE
B = 7/8" DIA. (22mm) HOLE FOR WATER INLET
C = 1/4" DIA. (6mm) HOLES FOR MOUNTING PLATE TO WALL
PAGE 297642C (Rev. C - 11/01)
1. Wall should already be framed for the fountain using dimensions shown in Fig. 3. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1. (and ADA) (Framing shown for reference only).
2. Remove bottom cover from fountain and save the screws. Assemble push rod to fountain. (Push rod provided with frost-resistant box)
3. Install the fountain using bolts and washers (provided). Tighten securely.
4. Attach drain tube to fountain and cut to required length using the frost resistant box as a guide.
5. Install frost-resistant box - see box instructions.
6. Install a service stop (not provided) and make water supply connection from the stop to the strainer in the frost-resistant box.
7. Connect fountain water line to frost-resistant box - see box instructions. Replace bottom cover.
HT-SBP-FR, HT-EBP-FR, HT-SEBP-FR
HT - EBP - FR ROUGH-IN
FINISHED FLOOR
FIG. 4
PAGE 3 97642C (Rev. C - 11/01)