This water cooler is certified to
NSF/ANSI 61.
GENERAL
Modular, electric refrigerated, bi-level wallmounted water cooler designed to be easily
accessible to physically challenged and ablebodied individuals. When properly installed,
unit meets state and federal requirements as
defined by the Americans with Disabilities Act.
Unit is certified to NSF/ANSI 61 and meets
requirements of the Safe Drinking Water Act.
Unit provides 50° F water at 80° F inlet water
and 90° F ambient.
FOUNTAIN
Face-mounted, one-piece, non-corrosive
stainless steel cooler top, number 300 series
with satin finish and contour-formed basin.
BUBBLER
Exclusive one-piece, chrome-plated two-stream
mound-building bubbler with non-removable
anti-squirt feature and integral hood insures a
satisfying drink of water.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to
prevent tampering. Unit resists corrosion and
liming. A constant stream height is automatically
maintained under line pressures that vary from
20 to 105 psi.
AUTOMATIC ACTUATION
Model HRFSEREE-Q features infra-red light
beam emitting sensor and a solenoid valve on
the extended right receptor. Upon interruption of
the light beam, the sensor actuates the
solenoid valve to flow water. User does not
have to touch the water cooler to obtain a
drink of water. Supplied with a built-in time
delay to avoid nuisance actuation from
passers-by. The left side features a pushbutton
valve with automatic stream regulator.
INLET STRAINER
Easily cleaned in-line strainer screen traps
particles of 140 microns or larger before they
enter the waterway.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor
with lifetime lubrication and built-in overload
protection, efficient capillary sizing, large
capacity dryer-strainer, and self-lubricated fan
cools copper/aluminum condenser. System
uses R134A refrigerant. Protected by Halsey
Taylor’s Limited 5 Year Warranty.
MOUNTING FRAME
Mounting frame is manufactured of corrosion
resistant, galvanized steel. Open construction
designed for ease of installation. Mounting
frame can be shipped in advance for rough-in
installation.
PANELS
Constructed of stainless steel, number 300
series with satin finish. Removable lower panel
providing access to plumbing and refrigeration
system. Panels overlap wall opening
1
/
2"
.
SUGGESTED SPECIFICATIONS
Shall deliver 7.5 GPH of 50° F water at 90° F
ambient and 80° F inlet water. Fountain shall
include infra-red sensor, contour-formed basin
to eliminate splashing and standing water, and
rounded corners and edges. Bubbler shall be
chrome plated, two-stream, mound- building
type. Cooling unit shall have a high efficiency
positive start compressor using R134A,
with pressurized counterflow cooling
evaporator/chiller. Cooler shall comply with
ANSI 117:1 and ADA for visual and motion
disabilities. The manufacturer shall certify the
unit to meet the requirements of NSF/ANSI 61,
and the Safe Drinking Water Act. Unit complies
with ARI Standard 1010.
NOTE: Continued product improvement makes
specifications subject to change without
notice. See Halsey Taylor website for most
current spec sheet.
NOTE: Water will only flow from bubbler
when unit has electrical connection.
Standard finish is Stainless Steel
Optional Accessories (extra cost)
■■
Cane Touch Apron
■■
Easy-Flex™Bubbler
■■
Water Filter
■■
Vandal Resistant Kit
Each HRFSEREE-Q consists of 3 cartons
as follows:
Mounting Frame
Cooling Unit-SJ8-Q
Fountain, Panels & Misc. Parts
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
A29 / 8-2007
MODEL HRFSEREE-Q
Barrier-Free Cooler
Bi-Level Electronic Eye
Contour
™
Series
halseytaylor.com
HRF BARRIER-FREE SERIES
Model GPH Capacity Base F.L. Shipping Rated
No. Cooled to 50° F* Rate Amps Weight Watt
Ambient Air Temp
Cap. lb. Usage
70°F 80°F 90°F†100°F
HRFSEREE-Q 9.3 8.3 7.5 6.8 7.5 4.0 135 370
* With projector service and tap water at 80° F
For additional specification of the cooling unit, see specification sheet for Model SJ8 Remote in this catalog.
†
UL listed and complies with ARI Standard 1010
Service stop not included
JOB NAME:
ENGINEER/CONTRACTOR NAME:
APPROVAL:
DATE: