HRFERQ*C HRFSRQ*C HRFSERQ*C HRFESRQ*C
Owners Manual
Contour™ Series Water Coolers
Refrigerated Fountains with Back Panel
Figure 1 – HRFSER
Figure
1
2
3
Not Shown
Model
HRFSER
HRFER
HRFSR
HRFESR
Figure 2 – HRFER Figure 3 – HRFSR
Description
ContourTM Series - Dual Installation
ContourTM Series - Extended Reach
ContourTM Series - Standard Reach
ContourTM Series - Dual Reversed Installation
INSTALLER
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.
Service to be performed by authorized service personnel only.
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices
to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which
results in an “electrolysis” effect occurring in the fountain. This may result in water which has a
metallic taste to it or has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the
installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation.
Any drain ttings provided by the installer should be made of plastic which will electronically isolate
the fountain from the remainder of the building’s plumbing circuits.
1
97800C - (Rev. K - 06/16)
HRFERQ*C HRFSRQ*C HRFSERQ*C HRFESRQ*C
1/4” O.D. TUBE
WATER INLET
TO COOLER
NOTE: WATER FLOW
3/8” O.D. UNPLATED COP-
PER TUBE CONNECT
COLD WATER SUPPLY
DIRECTION
SERVICE STOP
(NOT FURNISHED)
Figure 4 – Water Supply Connections
Item Part No. Description
Drain
Kit - Retaining Nut (5 Pack)
Strainer & Ferrule Assy
Kit - Bubbler/Nipple/Gasket Assy
Push Button
Push Button Sleeve
Regulator Holder
Edge Trim - 2FT
Regulator
Cap screw
Screw - #10-24 X .50” PHTC
Strainer (Supplied with Chiller)
Fountain Arm-Short
Fountain Arm-Extended
Bottom Cover Plate-Short
Bottom Cover Plate-Extended
Back Panel HRF-SER
Back Panel HRF-ESR
Back Panel HRF-ER
Back Panel HRF-SR
Kit - Hex Nut (4 Pack)
Poly Tubing - 1/4 (Cut To Length)
Bracket-Regulator Mounting
Lower Panel HRF-SER/ESR
Lower Panel HRF-ER/SR
Kit - Union-1/4” (3 Pack)
Kit - Tee-1/4” (3 Pack)
10
11
12
13
14
15
16
17
18
19
20
21
1
2
3
4
5
6
7
8
9
LK464
1000002027
45336C
98533C
45662C
45663C
50986C
56369C
61313C
75672C
112627543890
55996C
28782C
28783C
55000661
55000665
26839C
27028C
26837C
26835C
1000001926
56092C
28823C
27026C
26833C
1000002162
1000001994
BUILDING WATER
INLET
Parts List
Installation Package
The components for installation are packed in three
separate boxes, regardless of the type of unit being
installed. The boxes contain the following:
Box No. 1: Wall Frame(s)
Box No. 2: Remote Chiller, SJ8
Box No. 3: Fountain(s), Arm(s) and Panels
Additional materials, as noted in the Parts List, are also
shipped in these boxes.
Number Required
HRFER
1
1
1
1
1
1
1
1
1
1
7
1
-
1
-
1
-
-
1
-
3
1
1
-
1
1
1
HRFSR
1
1
1
1
1
1
1
1
1
1
5
1
1
-
1
-
-
-
-
1
3
1
1
-
1
1
1
HRFSER
2
2
2
2
2
2
2
2
2
2
12
1
1
1
1
1
1
-
-
-
6
1
2
1
-
1
1
HRFESR
12
See Fig.
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
-
1
-
-
6
1
2
1
-
1
1
18
17
18
18
17
17
17
18
17
17
18
4, 15, 19
18
18
18
18
12, 13, 18
18
12, 13, 18
12, 13, 18
17
18
17
14, 18
14, 18
19
15
97800C - (Rev. K - 06/16)
2
HRFERQ*C HRFSRQ*C HRFSERQ*C HRFESRQ*C
Models
HRFSER & HRFESR
1. Cut a rectangular wall opening 37-1/2” (953 mm) W
x 37-3/4” (959 mm) H and 4-1/2” (114 mm) above the
oor line (see Figure 6). The dimensions are required
to obtain proper rim and bubbler heights for compliance
with ANSI standard A117.1.
2. Reinforce the wall opening on all sides to adequately
support the water fountain. This reinforcement must
support up to 150 lbs. static load and provide a means
for securing the frame assembly in place.
NOTE: Building construction must allow for adequate
air ow on both sides, top and back of chiller.
A minimum of 4” (102 mm) on both sides and
top is required. See chiller installation for
additional instructions.
3. Install plumbing and electrical rough-ins. A junction
box for a (3) wire, 10 amp branch circuit is provided
on the inside of the chiller. (Standard 120 Volts, 60 Hz,
and single phase.)
Figure 5 – HRFSER Rough-In
REVERSED CONFIGURATION:
HIGHER UNIT ON THE RIGHT
4. Remove frames and related hardware from
packaging. Release the two shelf rods by cutting cable
ties. Attach the two frames together through the upright
supports with (4) 5/16” x 3/4” (19 mm) long bolts and
nuts (provided). Tighten securely.
MAKE SURE FRAME CONFIGURATION
MATCHES THE COOLER TO BE INSTALLED
STANDARD CONFIGURATION
HIGHER UNIT ON THE LEFT
Figure 6 – Rough-In Assembly
Dual-Station Mounting Frames
3
97800C - (Rev. K - 06/16)