Halsey Taylor HRFEREEQ-2C Installation Manual

HALSEY TAYLOR OWNERS MANUAL
CONTOUR
HRFEREEQ*C HRFEREEQ*2C HRFSEREEQ*C
TM
Series Electronic Eye Barrier-Free Water Coolers
Refrigerated Fountains with Back Panel
Figure
1 2
Model
HRFER-EE-Q
HRFSER-EE-Q
Fig. 2 – HRFSER-EE-Q
Description Contour Series - Extended Reach Contour Series - Dual Installation
INSTALLER
Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left in the plastic bag provided inside the installed unit for future reference.
Service to be performed by authorized service personnel only .
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to
available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in an “electrolysis” effect occurring in the fountain. This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation. Any drain fittings provided by the installer should be made of plastic which will remainder of the building’s plumbing circuits.
1
electronically isolate the fountain from the
97880C (Rev. C - 7/09)
HRFEREEQ*C HRFEREEQ*2C HRFSEREEQ*C
1/4" O.D. TUBE
WA TER INLET
TO COOLER
NOTE: WA TER FLOW
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WA TER SUPPL Y
DIRECTION
SERVICE STOP
(NOT FURNISHED)
Figure 3 – Water Supply Connections
Item Part No. Description
1
2
3 4 5
6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
26 27 28 29 30 31 32 33 34 35
97880C (Rev. C - 7/09)
26837C 26839C 26833C 27026C
55000604
27623C 55000661 55000665
100322740560
111008343890 111577243890 111577343890
112627543890
15005C
22525C
28823C
27240C
31375C
36286C
31384C 38417001
40045C
45662C
45663C
50203C
50986C
51409C
51544C
55905C
56082C
56092C
56159C
61313C
70016C
70208C
70682C
70683C
70817C
70989C
Upper Panel (HRFER-EE) Upper Panel (HRFSER-EE) Lower Panel (HRFER-EE) Lower Panel (HRFSER-EE) Standard Reach Arm Extended Reach Arm (EE) Bottom Cover - Standard Reach Bottom Cover - Extended Reach (EE) Bubbler Gasket Screw #10-24 x .62 HHMS Screw 5/16-18 x .75 Hex Nut 5/16-18 Screw #10-24 x .50 PHTC Regulator Retaining Nut Regulator Mounting Bracket Regulator Mounting Bracket Support Bracket Solenoid Valve Assy. Power Cord Sensor Assy. Screw #8-18 x .37 HHSM Hex Nut Push Button Push Button Sleeve Strain Relief Bushing Regulator Holder Spacer Bubbler Bubbler - EasyFlex (Option) Regulator Nut Poly Tubing 1/4” (Cut To Length) Bubbler Nipple Regulator - W/Red Spring Nut Screw Fitting - Tee 1/4” Fitting - Union 1/4” Fitting - Elbow 1/4” Ground Screw #8-36 x .37
BUILDING WA TER INLET
Parts List
2
Installation Package
The components for installation are packed in three separate boxes, regardless of the type of unit being installed. The boxes contain the following:
Box No. 1: Wall Frame(s) Box No. 2: Remote Chiller, SJ8-Q Box No. 3: Fountain(s), Arm(s) and Panels
Additional materials, as noted in the Parts List, are also shipped in these boxes.
Number Required
HRFER-EE-Q
1
-
1
-
-
1
­1 2 4 4 4 7
­1
­1 1 1 1 2 1
-
­1 1 2 1 1 1 1 1 1 2 2
­1 1 1
HRFSER-EE-Q
-
1
­1 1 1 1 1 4 5 8 8
12
1 1 1 1 1 1 1 2 4 1 1 1 2 2 2 2 1 1 2 2 2 2 1
­1 1
See Fig.
11, 22 11, 22 13, 22 13, 22
5, 8 5, 8 5, 8
5, 8
20, 21
20, 21
15, 16
20, 21
22 22 22 22 19
22 20 21 20 21 18 18 21
20 20 21
21 19 19 26
19
21 21 16 15 18 18
HRFEREEQ*C HRFEREEQ*2C HRFSEREEQ*C
Parts List Continued
Item
36 37 38 39 40 41 42 43 44
N-S
Part No. Description
75507C 75672C
LK464 45336C 45784C 45796C 50074C
72001527
55996C 75674C
N-S means not shown
Fitting - 1/4” NPTF Cap Screw #6-32 x .25 Drain Assy. (Includes items 39 thru 43) Strainer & Ferrule Assy. Drain Trap Fitting - Elbow 1/4” T ailpipe Gasket Rubber Washer Strainer (Supplied with Chiller) Allen Wrench 7/64
HRFER-EE-Q HRFSER-EE-Q
2
­1 1 1 1 1 1 1 1
2 1 2 2 2 2 2 2 1 1
See Fig.
18 20 22 22 22 22 22 22
15, 16
-
3
97880C (Rev. C - 7/09)
HRFEREEQ*C HRFEREEQ*2C HRFSEREEQ*C
Models
HRFSER-EE-Q
1. Cut a rectangular wall opening 37-1/2” (953 mm) W x 37-3/4” H (959 mm) and 4-1/2” (114 mm) above the floor line (see Figure 5). The dimensions are required to obtain proper rim and bubbler heights for compliance with ANSI standard A117.1.
2. Reinforce the wall opening on all sides to adequately support the water fountain. This reinforcement must support up to 150 lbs. static load and provide a means for securing the frame assembly in place.
NOTE: Building construction must allow for adequate air
3. Install plumbing and electrical rough-ins. A junction box for a (3) wire, 10 amp branch circuit is provided on the inside of the chiller. (Standard 120 Volts, 60 Hz, and single phase.)
4. Remove frames and related hardware from packaging. Release the two shelf rods by cutting cable ties. Attach the two frames together through the upright supports with (4) 5/16” x 3/4” (19 mm) long bolts and nuts (provided). Tighten securely.
flow on both sides and top of remote chiller unit a minimum of 4” (102 mm) is required.
Figure 4 – HRFSER-EE-Q Rough-In
5/16" SCREWS OR BOLTS
(12 REQ'D - NOT FURNISHED)
FRAME
5/16" HEX NUT
(4 REQ'D - PROVIDED)
P/N 111577343890
15
18
INSTALL (3) SCREWS
(P/N 111008342890) IN FRA ME
BEFORE INSTALLING IN OPENING
97880C (Rev. C - 7/09)
SCREWS OR BOLTS (NOT PROVIDED)
HOOK RODS (2) P/N 101567442730
CHILLER SHELF P/N 27638C
BOLT FRAMES TOGETHER WITH 5/16" x 3/4" (19mm) BOLTS (4 REQ'D - PROVIDED) P/N 111577243890
Figure 5 – Rough-In Assembly
Dual-Station Mounting Frame
4
Loading...
+ 7 hidden pages