Installer T o assure you install this model easily and correctly , PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE ST ARTING THE INST ALLA TION. CHECK YOUR INST ALLA­TION FOR COMPLIANCE WITH PLUMBING , ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference. This Freeze Resistant Fountain is shipped in two separate cartons. The second carton(s) contains the Freeze Resistant Package(s) HTFRB1 that are installed on an interior heated wall. The interior space must maintain a minimum temperature of 50° F (10° C). Refer to the Freeze Resistant Package for the rough-in dimensions for installation.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WA TER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR A WA Y FROM THE BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELECTROLYSIS WHICH CAUSES A METALLIC T ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS A VOIDABLE BY USING THE PROPER MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALL Y ISOLA TE THE FOUNT AIN FROM THE BUILDING PLUMBING SYSTEM.
PAGE 1 97649C (Rev. P - 4/09)
HRFSBP - FR HRFEBP - FR HRFSEBP - FR HRFESBP - FR
The freeze resistant package must be mounted on an interior wall in a heated area. The room temperature of the interior heated area must be 50° F (10° C) or higher. The freeze resist ant package may be surface or recessed mounted. If recess mounted the surface of the cover must be flush with the interior wall surface. The package is furnished with screws for mounting the cover to the box. If the box is recess mounted, do not fasten the top and bottom of the cover to the box. Use the holes on the front only.
1. Fountains using the MPW Mounting Plate refer to Fig's. 7, 1 1, or 15 for hanger bracket location and rough-in dimensions. NOTE: Review separate installation instructions for details of the MPW Mounting Plate. Fountains using the Wall Plate Assy . refer to Fig's. 3, 5, 9, or 13 for rough-in dimensions.
2. Shown dimensions pertain to installation location (framing must support up to 150 lbs. weight for single fountain and 300 lbs. for dual fountains). These dimensions are required for compliance with ANSI Standard A1 17.0.
3. Installing back panel. Ftn. w/MPW Mounting Plate: Refer to Fig. 24 for placement of braces onto back panel. Place the upper edge of the panel above hanger bracket. Slide the panel down until it engages the hanger bracket. Be sure back panel is firmly engaged before releasing it. Ftn. w/Wall Plate Assy .: Place the upper edge of the panel above mounting plate on the wall. Slide the panel down until it engages the hanger . Be sure back panel is firmly engaged before releasing it.
4. Remove bottom access panel from fountain basin and save the screws. Ftn. w/Back Panel: Install fountain to back panel and wall using (4) 5/16" x 2.00" long lag bolts and washers (NOT PROVIDED). Ftn. w/MPW Mounting Plate: Install the fountain to the back panel and wall using (4) 5/16 “ x 6” long threaded rods, washers, and nuts (provided). Tighten securely . Ftn. w/Wall Plate Assy .: Install the fountain to the back panel and wall using (4) 5/16" x 3/4" long bolts and washers (provided) thru holes in back panel. A washer is used on the bottom two (2) holes only. Tighten securely .
5. Assemble the operating cable to the fountain bracket. (Fount ain should be mounted to exterior wall) Create a loop in the cable and thread the free end of the cable through the wall into the freeze resistant box. The adjustment nuts should be in the middle of threaded area on the operating cable. See Figure 18.
6. Connect free end of operating cable to the valve-operating bracket. The end of the cables must be recessed into the indents on the pivot
brackets. Remove cable free play by adjusting the jam nuts on the ends of the operating cable. See Figure 18.
7. Connect water line from fountain bubbler into freeze resistant box. The connection to the box uses a quick connect water fitting. Position the
water line, in the fountain, to drain back into interior mounted box. Any water lef t standing, in the exterior line, can freeze . See Fig. 21. T o insert tubing, push tube straight into fitting until it reaches a positive stop. T o remove tubing from the fittings, relieve water pressure, push in
on dark gray collar while pulling out on the tubing. See Figure 2.
8. Connect drain and water supply lines to the freeze resistant fountain. Refer to Figure's 3 thru 16 for component positions.
Inline strainer must be used on the inlet water line. See Fig. 1.
Start-up
1. Turn on building water supply and check all connections for leaks. Repair as required.
2. Stream height is factory set at 35 PSI. If stream height needs to be changed adjust the regulator in the freeze resistant package. Clockwise
adjustment raises stream height, counter clockwise adjustment will lower stream.
3. Adjust operating cable as required. Cable system should have a minimal amount of free play to allow for proper valve operation. If the system is too tight the valve will stay in the on position creating constant water flow . Too much free play will result in non-operation of the valve with the push-buttons.
4. Note: Water from the drain back tube in the freeze resistant package, will continue to run while the valve is actuated.
5. After cable system is adjusted properly stuf f flexible insulation into any openings between the outside wall and the interior box.
6. Recheck all connections. If all connections are leak free replace cover(s) on the freeze resistant box(es) and fountain(s).
1/4" O.D. TUBE WATER INLET
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WA TER SUPPLY
BUILDING WATER
INLET
OPERA TION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS
SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
NOTE: WA TER FLOW DIRECTION
FIG . 1
SERVICE STOP (NOT FURNISHED)
PAGE 297649C (Rev. P - 4/09)
FIG . 2
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
HRFSBP - FR HRFEBP - FR HRFSEBP - FR HRFESBP - FR
HRFSBP - FR WITH WALL PLATE ASSY.
MOUNTING BOLT AND ACCESS HOLE LAYOUT
FIG . 3
LEGEND
A = 1-3/4" DIA. (44mm) HOLE FOR W ASTE LINE
B = 7/8" DIA. (22mm) HOLE FOR WA TER
SUPPLY TUBE
C = 7/8" DIA. (22mm) HOLE FOR OPERA TING
CABLE
D = 1/4" DIA. (6mm) HOLES FOR MOUNTING
PLA TE TO WALL
PAGE 3 97649C (Rev. P - 4/09)
HRFSBP - FR HRFEBP - FR HRFSEBP - FR HRFESBP - FR
ROUGH-IN DRA WINGS
HRFSBP - FR WITH WALL PLATE ASSY.
FIG . 4
1. Wall should already be framed for the fountain using dimensions shown in Fig. 3. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1. and ADA (Framing shown for reference only).
2. Remove bottom cover from fountain and save the screws.
3. Install the fountain using bolts and washers (not provided). Tighten securely.
4. Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide.
5. Install freeze-resistant box - see box instructions.
6. Replace bottom cover.
PAGE 497649C (Rev. P - 4/09)
HRFSBP - FR HRFEBP - FR HRFSEBP - FR HRFESBP - FR
HRFEBP - FR WITH WALL PLATE ASSY.
MOUNTING BOLT AND ACCESS HOLE LAYOUT
FIG . 5
LEGEND
A = 1-3/4" DIA. (44mm) HOLE FOR W ASTE LINE
B = 7/8" DIA. (22mm) HOLE FOR WA TER
SUPPLY TUBE
C = 7/8" DIA. (22mm) HOLE FOR OPERA TING
CABLE
D = 1/4" DIA. (6mm) HOLES FOR MOUNTING
PLA TE TO WALL
PAGE 5 97649C (Rev. P - 4/09)
HRFSBP - FR HRFEBP - FR HRFSEBP - FR HRFESBP - FR
ROUGH-IN DRA WINGS
HRFEBP - FR WITH WALL PLATE ASSY.
FIG . 6
1. Wall should already be framed for the fountain using dimensions shown in Fig. 5. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1. and ADA (Framing shown for reference only).
2. Remove bottom cover from fountain and save the screws.
3. Install the fountain using bolts and washers (not provided). Tighten securely.
4. Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide.
5. Install freeze-resistant box - see box instructions.
6. Replace bottom cover.
PAGE 697649C (Rev. P - 4/09)