THIS IS AN INDOOR APPLICATION ONL Y .
ALL SERVICE TO BE PERFORMED BY AN
AUTHORIZED SERVICE PERSON.
TOOLS REQUIRED
BUT NOT PROVIDED:
SAFETY GLASSES
GLOVES
ELECTRIC DRILL
3/4” WRENCH OR CRECENT WRENCH
UTILITY KNIFE
T APE MEASURE
PENCIL
5/32” ALLEN WRENCH
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WA TER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR A WA Y FROM THE
BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELECTROL YSIS WHICH CAUSES A MET ALLIC T ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WA TER.
THIS CONDITION IS A VOIDABLE BY USING THE PROPER MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS
PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC T O ELECTRICALLY ISOLA TE THE FOUNT AIN
FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THA T THE BOTTLE FILLING ST A TION AND W A TER
COOLER BE PROTECTED BY A GROUND F AUL T CIRCUIT INTERRUPTER (GFCI).
INSTALLER
HTHB-HAC Bottle Fillers are among the easiest to install on the market today. To
insure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND
OTHER APPLICABLE CODES. After installation, leave these instructions with the
Fountain for future reference.
Page 198657C (Rev. B - 1/11)
NOTE:
HAC-HB*1A
WATER COOLER PREPARATION
• On T wo Level Models, the Bottle Filling Unit MUST be mounted on the higher unit:
• Two Level S tandard Models; high unit is on Lef t Hand(LH) side.
• Two Level Reverse Models; high unit is on Right Hand(RH) side.
1) Remove Front Panel
• Remove lower front panel of water cooler by
removing the four (4) screws, two at top
and two at bottom. On T wo Level Models,
remove both front panels.
• W ARNING: Before proceeding.
Disconnect electrical power supplying the water
cooler . Switch circuit breaker “OFF” or remove
fuse.
• Unplug water cooler power cord from electrical
outlet.
• Shut of f water supply .
Remove Front Panel
Loosen Drain Line
2) Loosen Drain Line
•
Loosen Slip-Joint Nut at P-trap.
•
Note: Have container/bucket readily available to
catch water from lines.
3) Remove Basin Fasteners
Remove Basin Assembly by loosening eight (8)
screws, four on each side of basin.
Remove Basin Fasteners
Page 298657C (Rev. B - 1/11)
WATER COOLER PREPARATION
4) Remove Bubbler Water Line
Disconnect water line from bubbler.
HAC-HB_1A
5) Lift and Remove Basin.
Remove basin assembly by lifting straight
up, disconnecting the drain line from
the P-trap.
5) Exchange Drain hardware.
• Remove drain hardware from original basin.
• Verify that the rubber washers are also
removed for reuse.
• Remove the drain tube from the elbow.
• Shorten the horizontal length of the
drain tube by 7/8”.
• Re-attach the drain tube to the elbow.
• Remove the protective covering from the
basin.
• Attach the drain hardware onto the new
basin ensuring drain is positioned exactly
as original.
7) Exchange Bubbler hardware.
••
• Remove bubbler hardware from original
••
basin.
••
• V erify that the rubber washers are also
••
removed for reuse.
••
• Reinstall the bubbler hardware on to the
••
new basin.
••
• Ensure the bubbler is properly positioned
••
with the stream falling onto the center of
splash ridge.
Remove Bubbler Water Line
Lift and Remove Basin.
Exchange Drain hardware.
Exchange Bubbler hardware.
Page 398657C (Rev. B - 1/11)
HAC-HB*1A
HWF3000 WATERSENTRY PLUS FILTER INSTALLATION
WARNINGS:
• Do not use with water that is microbiologically unsafe or of unknown quality . For potable water only.
• Do not use with a hot water supply . Rated for water temperature: 33°-100°F(2°-38°C)
• Water line pressure must not exceed 100psi(690kPa). Use an inline water pressure regulator before filter
to limit maximum pressure. Rated water supply pressure: 20-100psi(138-690kPa).
• Filter kits must be installed in compliance with all state and local laws and regulations governing the
installation and use of this product.
NOTE:
• Ends of tubing must be cut square and free of
burrs and sharp ends that could cut or nick
the o-rings.
• Loosen the locknut and push tube end past
both o-rings to a positive stop in the filter
head recess - approx. 1".
• Locknut may have to be backed out a little
more. Screw the locknut hand tight to seal.
Note: Screw the locknut hand tight to seal
Attach port fittings onto Filter Head
Single Level Models
1) Attach port fittings onto Filter Head:
• Note: Refer to photos at left for proper
alignment.
• Insert 3/8" 90° Elbow fitting into IN port,
• Insert ¼” poly tube into OUT port. If
necessary, insert a ¼” x 90° Elbow.
• Adjust and tighten port fittings.
2) Attach Filter head assembly.
• If not already preassembled. Attach Filter
head assembly to filter mounting bracket
with four(4) screws supplied.
••
• Single Level Models
••
••
• Mount with 3/8” inlet on
••
Right Side
Two Level Models
••
• T wo Level Models
••
••
• Mount with 3/8” Inlet on
••
Left Side