GENERAL
Energy-efficiency performance exceeds average market performance by 35%
Self-contained, high-efficiency refrigerated wall-
mount water cooler is easily accessibly for
physically challenged individuals. Meets state and federal accessibility requirement, including Americans with Disabilities Act. Unit is certified
to NSF/ANSI 61& 372 and meets requirements of Safe Drinking Water Act. Unit provides 50°F
water at 80°F inlet water and 90° F ambient.
CABINET
Stainless steel panels resist wear and corrosion.
Durable satin finish helps hide water spots and fingerprints.
COOLER TOP
Non-corrosive stainless steel cooler top, no. 300 series with satin finish resists stains and corrosion and is easy to maintain. Anti-splash ridge reduces splatter. Contoured to insure proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two­stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSH BAR ACTUATION MECHANISM
Self-closing, light-touch push bars on front and
sides with raised letters for the visually
impaired.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to
prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling temperature of storage tank water. Factory set at 50° F Adjustable ± 5° F.
STORAGE TANK
Stainless steel evaporator/storage tank for
long life. Waterways are certified to NSF/ANSI 61, far exceeding the requirements of the Safe Drinking Water Act.
REFRIGERATION SYSTEM
High-efficiency, hermetically sealed, positive start compressor with lifetime lubrication and
built-in overload protection, efficient capillary
sizing, large capacity dryer-strainer, and self-
lubricated fan cooled condenser. System uses
R134a refrigerant. Protected by Halsey Taylor’s Limited 5 Year Warranty
VENTILATION
Insure proper ventilation by maintaining 6" (152mm) minimum clearance from cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall include high-efficiency refrigeration system.
Shall deliver 8.0 GPH of 50°F water at 90° F ambient and 80° F inlet water. Shall have stainless steel basin with removable drain
strainer. Bubbler shall be two-stream, mound
building type. Separate valve and automatic
stream regulator shall be mounted within
cabinet. Refrigeration system shall employ high
efficiency, positive start compressor using R134A, non-pressurized tank with totally
encapsulated insulation and be controlled by
positive sensing thermostat. Shall have front and side push-bar water controls with raised lettering for the visually impaired. Cooler shall comply with ANSI 117:1 and ADA for visual and motion disabilities. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61 & 372 and the Safe Drinking Water Act. Unit complies with ARI Standard 1010.
NOTE: Continued product improvement
makes specifications subject to change
without notice. See Halsey Taylor website for most current spec sheet.
Barrier-Free Cooler
Optional Accessories (extra cost)
98312C PV Cane Touch Apron
98324C SS Cane Touch Apron
JOB NAME:
ENGINEER/CONTRACTOR NAME:
HAC-Q BARRIER-FREE SERIES
Ambient Air Temp
70°F 80°F 90°F†100°F
HACG8BL*-NF 062298.20.82.70.88.87.9
*
Finish indicator: PV for Platinum Vinyl and SS for Stainless Steel cooler panels
**With projector service and tap water at 80° F
UL listed and complies with ARI Standard 1010
Trap and service stop not included
HALSEY TAYLOR, 2222 CAMDENCOURT, OAK BROOK, ILLINOIS 60523
halseytaylor.com
APPROVAL:
DATE:
detaRgnippihS.L.FesaByticapaC HPGledoM ttaWthgieWspmAetaR*F°05 ot delooC.oN
egasU.bl.paC
SPEC00119
/ 7-2013
HACG8BLPV-NF, HACG8BLSS-NF
High-Efficiency, Bi-Level Barrier-Free Cooler
(CONTINUED)
OPERATING PRESSURES:
Supply water - 105 psi maximum Minimum 40 psi supply line pressure required
in special circumstances when both sides of bilevel are in use simultaneously to ensure adequate stream height. Does not apply to non-refrigerated units.
ELECTRICAL
Furnished with plug-in, 3-wire grounding type service cord. Standard 120 volt, 60 Hz, single phase. Install 120-volt receptacle, rated at 15-amp minimum, to receive 3-wire parallel blade grounding type male plug.
Trap and service stop not included.
WEIVEDISWEIVTNORF
18 1/16" 459mm
11/16" 18mm
2 7/16" 63mm
B
5 3/4" 146mm
5 3/4" 146mm
1 3/8" 35mm
6 1/4" 159mm
C
L
1 3/8" 35mm
3 1/2" 89mm
4 1/2" 114mm
5 3/4" 146mm
13 7/8" 352mm
D
E
A
F
18 3/4" 476mm
20 1/8" 511mm
25 1/8" 638mm
39 1/2" 1003mm
ORIFICE HEIGHT
33" 838mm
ORIFICE HEIGHT
2 9/16" 65mm
31 7/8" 810mm
RIM HEIGHT
27"
*
686mm
8" 203mm
5/16" (8mm) DIA. (10 HOLES)
6 1/2" 165mm
E
7 1/4" 185mm
F
37 1/2" 952mm
2 9/16" 65mm
20 3/8" 518mm
5 3/4" 146mm
4 9/16" 116mm
5" 127mm
1 3/8" 35mm
C
L
FINISHED FLOOR
1 3/8" 35mm
10" 254mm
*Adult ADA requirement. 24" (609mm) for Child ADA.
Adjust other measurements accordingly.
A. RECOMMENDED WATER SUPPLY LOCATION. 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB
1-1/2" (38 mm) OUT FROM WALL SHUT OFF VALVE NOT FURNISHED. B. RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN C. 1-1/2" TRAP NOT FURNISHED D. ELECTRICAL SUPPLY (3) WIRE RECESSED BOX E. INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL F. 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL
18 5/8" 473mm
HANGER BRACKET
C
4 1/8" 105mm
12 5/16" 313mm
6 3/4" 172mm
SPEC00119 07/2013
Printed in the
U.S.A.
Loading...