Halsey Taylor HACFSCDWSBL-1D, HAC8FSCWSBLQ-1D Installation Manual

HACFSCWSD*1D HAC8FSCWSBLQ*1D HACFSCDWSBL*1D HAC8FSCWSBLQ*1D HACFSCWSDBL*1D
Installation/Care/Use Manual
HTHB-HAC Factory Prep
Hydroboost Bottle Filling Station and Cooler
IMPORTANT
THIS IS AN INDOOR APPLICATION ONL Y . ALL SERVICE TO BE PERFORMED BY AN
AUTHORIZED SERVICE PERSON.
TOOLS REQUIRED
BUT NOT PROVIDED:
SAFETY GLASSES GLOVES ELECTRIC DRILL 3/4” WRENCH OR CRECENT WRENCH 5/16” NUT DRIVER UTILITY KNIFE T APE MEASURE PENCIL CENTER PUNCH 1/2” SOCKET & RA TCHET WRENCH 5/32” ALLEN WRENCH
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WA TER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR A WA Y FROM THE BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELEC­TROL YSIS WHICH CAUSES A MET ALLIC T ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WA TER. THIS CONDITION IS A VOIDABLE BY USING THE PROPER MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC T O ELECTRICALLY ISOLA TE THE FOUNT AIN FROM THE BUILDING PLUMBING SYSTEM. WE SUGGEST THA T THE BOTTLE FILLING ST A TION AND W A TER COOLER BE PROTECTED BY A GROUND F AUL T CIRCUIT INTERRUPTER (GFCI).
INSTALLER
HTHB-HAC Bottle Fillers are among the easiest to install on the market today. To insure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference.
Page 1 98658C (Rev. B - 1/11)
HACFSCWSD*1D HAC8FSCWSBLQ*1D HACFSCDWSBL*1D HAC8FSCWSBLQ*1D HACFSCWSDBL*1D
18
47
6 3/4"
172mm
12 5/16"
313mm
ADA REQUIREMENT
*
686mm
*
3 9/16"
1 1/2"
38mm
90mm
HANGER BRACKET
18 5/8"
473mm
C
6 1/4"
159mm
8"
203mm
27"
2 9/16"
65mm
31 7/8"
810mm
RIM HEIGHT
HTHB-HAC
7"
178mm
17 7/8"
454mm
7"
178mm
O
(6)
7/16"
11mm
MOUNTING HOLES
33"
838mm
ORFICE HEIGHT
3 3/16"
15"
381mm
5 3/4"
146mm
82mm
2 9/16"
1 3/8"
35mm
7 1/4"
11/16"
185mm
18mm
E
4 9/16"
116mm
L
C
65mm
F
2 1/2"
64mm
3 1/2"
2 7/16"
63mm
13 7/8"
352mm
89mm
4 1/2"
114mm
FINISHED FLOOR
10"
254mm
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
5"
127mm
A
D
B
E
1 3/8"
5 3/4"
146mm
5/16" (8mm) DIA. (5 HOLES)
35mm
25"
635mm
31"
787mm
18 3/8"
467mm
21 3/8"
543mm
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION. 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB
1-1/2" (38mm) OUT FROM WALL. SHUT OFF VALVE NOT FURNISHED.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN
C = 1-1/4" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX, DUPLEX OUTLET REQUIRED
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MIN. CLEARANCE FROM CABINET
LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL
51 7/16"
1306mm
Single Rough-In
Fig. 1
Page 298658C (Rev. B - 1/11)
Loading...
+ 4 hidden pages