FILTER KIT
HWF172 WATERSENTRY® VII KIT (Lead, Cyst, Sediment, Taste & Odor Reduction)
FOR COMMERCIAL USE ONLY
These filter kits are designed to be used with the following
Halsey Taylor products:
HAC-Q, HAC-BL-Q, SCWT-A-Q, S-D-Q
NOTICE: Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.
General Installation Instructions
1. These filter kits must be installed in compliance with all
state and local laws and regulations governing the
installation and use of this product. Maximum inlet
water temperature 100°F (38°C).
2. Mount filter head in a suitable location, using the filter
mounting bracket and screws supplied. Allow enough
room under the filter head for installation and removal of
filter cartridge (13" minimum).
3. Connect the cold water supply to the filter through a
shut-off valve and 3/8" O.D. tubing (supplied by the
installer). For ease of servicing, the shut-off valve
should be located within easy reach of the filter.
NOTE: The inlet and outlet fitting supplied as
part of the filter head are John Guest Superseal
fittings that accept 3/8" O.D. tubing on the filter
inlet and 1/4" O.D. tubing on the outlet. They may
be used with copper, st ainless steel, or semirigid
nylon or polypropylene tubing, with a rated working
pressure equal or greater than encountered in
application. Do not use soft or braided tubing.
4. CAUTION: If supply pressure will ever exceed
100 psi, install a pressure regulator to limit the
inlet pressure to the filter to 100 psi or below.
DO NOT A TT ACH HOT WA TER LINE TO FIL TER.
To make connections on the filter head, loosen locknut.
Push the tube end past both o-rings to a positive stop in
the filter head recess - approx. 1", locknut may have to
be backed out a little more. Screw the locknut hand tight
to seal (See Fig. 1). Ends of tubing must be cut square
and free of burrs and sharp ends that could cut or nick
the o-rings.
5. Connect the outlet of the filter to the inlet of the union
using the 1/4" O.D. poly tubing and 1/4" union supplied.
6. Remove filter from carton, remove protective cap, attach
filter to filter head by firmly inserting into head and
rotating filter clockwise.
7. Turn on water supply and hold open the bubbler on
cooler until approximately 1 gallon of water is dispensed.
This flushing procedure purges air and fine carbon
particles from the filter. When 1 gallon of water has been
purged through the cooler, carefully inspect all water
connections for leaks.
FIG. 1
See Note 4: Screw the locknut hand tight to seal
FIG. 2
Filter Replacement
1. Turn inlet water valve off.
2. Open bubbler to relieve pressure build up in the system.
3. Remove filter from head by rotating filter counterclock
wise.
4. Remove new filter from carton. Remove protective cap.
Cap may be placed on old filter to reduce the chance of
water spilling from filter housing.
5. Attach filter to filter head by firmly inserting into head and
rotation filter clockwise.
NOTE: The filter head contains an automatic shut-off
valve that stops the flow of water , if the filter is
removed inadvertently without shutting off thein
coming water.
RATED OPERATING CONDITIONS
Pressure (Min.)
Flow Rate
Temperature (Min.)
NOTE: Performance will vary depending
on local water conditions.
Page 1 97787C (Rev. D - 02/07)
20 PSI (1.5 Kg/cm2)
0.75 GPM
40° F (5° C)
Filter
T able A
REPLACEMENT FIL TER
Part No. Description
Halsey Taylor® WaterSentry® VII
Lead, Cyst Reduction, C.T.O. Filter55897C
The Halsey T aylor® WaterSentry® VII conforms to NSF/ANSI Standard 42 for reduction of Chlorine,
Particulate - Class I, and T aste and Odor; NSF/ANSI 53 for reduction of Lead and Cyst.
NOTE: If the flow exceeds the rated flow rate, install a flow restrictor , Part No. 50967C, to limit the flow to .5 gpm.
4
ITEMIZED P ARTS LIST
Item No. Part No. Description
*1
2
**3
4
5
6
7
8
9
10
22490C
38417002
51469C
70792C
56092C
70823C
70822C
See Table A
70683C
70818C
Bracket - Filter Mounting
Screw #8-18 x .50 (13mm) LG. HHSM
Filter Head & Bracket Assembly
Screw #8-18 x .75 (19mm) LG. PH
Poly T ubing(Cut to Length)
Fitting - Superseal 3/8" (10mm)
Fitting - Superseal 1/4" (6mm)
Filter Assembly
Union - 1/4" (6mm)
Elbow Adapter 3/8" x 3/8"
5
9
2
3
7
1
6
8
10
WHEN
REQUIRED
FIG. 3
*Note: Bracket can be turned over to provide better fit in some models.
**Item No(s). 1, 4, 6, and 7 included with item No. 3.
FIL TER LOCATION
HAC-Q
Page 297787C (Rev. D - 02/07)
HAC-BL-Q
S-D-Q
FIL TER LOCATION
FILTER
LOCA TION
SCWT-A-Q
FILTER
LOCA TION
Page 3 97787C (Rev. D - 02/07)
NOTICE
T o receive maximum benefit from your Halsey Taylor®WaterSentry® filters, note the installation dates below, and
change according to the following guidelines.
Halsey T aylor® WaterSentry® VII -- Lead/Cyst Reduction Filter
Change every 1,500 gallons, or once a year -- whichever occurs first.
- - KEEP THIS SHEET IN A HANDY LOCATION - -
DA TE
INST ALLED
MODEL
(TYPE OF FIL TER)
SERVICE
PERSON
DA TE
INST ALLED
MODEL
(TYPE OF FIL TER)
SERVICE
PERSON
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW.HALSEYTAYLOR.COM
PRINTED IN U.S.A.
Page 497787C (Rev. D - 02/07)