Halsey Taylor HAC-BL-Q Installation Manual

FILTER KIT
HWF172 WATERSENTRY® VII KIT (Lead, Cyst, Sediment, Taste & Odor Reduction)
FOR COMMERCIAL USE ONLY
These filter kits are designed to be used with the following Halsey Taylor products: HAC-Q, HAC-BL-Q, SCWT-A-Q, S-D-Q
NOTICE: Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection before or after the system.
1. These filter kits must be installed in compliance with all state and local laws and regulations governing the installation and use of this product. Maximum inlet water temperature 100°F (38°C).
2. Mount filter head in a suitable location, using the filter mounting bracket and screws supplied. Allow enough room under the filter head for installation and removal of filter cartridge (13" minimum).
3. Connect the cold water supply to the filter through a shut-off valve and 3/8" O.D. tubing (supplied by the installer). For ease of servicing, the shut-off valve should be located within easy reach of the filter.
NOTE: The inlet and outlet fitting supplied as part of the filter head are John Guest Superseal fittings that accept 3/8" O.D. tubing on the filter inlet and 1/4" O.D. tubing on the outlet. They may be used with copper, st ainless steel, or semirigid nylon or polypropylene tubing, with a rated working pressure equal or greater than encountered in application. Do not use soft or braided tubing.
4. CAUTION: If supply pressure will ever exceed 100 psi, install a pressure regulator to limit the inlet pressure to the filter to 100 psi or below. DO NOT A TT ACH HOT WA TER LINE TO FIL TER.
To make connections on the filter head, loosen locknut. Push the tube end past both o-rings to a positive stop in the filter head recess - approx. 1", locknut may have to be backed out a little more. Screw the locknut hand tight to seal (See Fig. 1). Ends of tubing must be cut square and free of burrs and sharp ends that could cut or nick the o-rings.
5. Connect the outlet of the filter to the inlet of the union using the 1/4" O.D. poly tubing and 1/4" union supplied.
6. Remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise.
7. Turn on water supply and hold open the bubbler on cooler until approximately 1 gallon of water is dispensed. This flushing procedure purges air and fine carbon particles from the filter. When 1 gallon of water has been purged through the cooler, carefully inspect all water connections for leaks.
FIG. 1
See Note 4: Screw the locknut hand tight to seal
FIG. 2
Filter Replacement
1. Turn inlet water valve off.
2. Open bubbler to relieve pressure build up in the system.
3. Remove filter from head by rotating filter counterclock wise.
4. Remove new filter from carton. Remove protective cap. Cap may be placed on old filter to reduce the chance of water spilling from filter housing.
5. Attach filter to filter head by firmly inserting into head and rotation filter clockwise.
NOTE: The filter head contains an automatic shut-off
valve that stops the flow of water , if the filter is removed inadvertently without shutting off thein coming water.
RATED OPERATING CONDITIONS
Pressure (Min.)
Flow Rate
Temperature (Min.)
NOTE: Performance will vary depending
on local water conditions.
Page 1 97787C (Rev. D - 02/07)
20 PSI (1.5 Kg/cm2)
0.75 GPM
40° F (5° C)
Filter
T able A
REPLACEMENT FIL TER
Part No. Description
Halsey Taylor® WaterSentry® VII
Lead, Cyst Reduction, C.T.O. Filter55897C
The Halsey T aylor® WaterSentry® VII conforms to NSF/ANSI Standard 42 for reduction of Chlorine,
Particulate - Class I, and T aste and Odor; NSF/ANSI 53 for reduction of Lead and Cyst.
NOTE: If the flow exceeds the rated flow rate, install a flow restrictor , Part No. 50967C, to limit the flow to .5 gpm.
4
ITEMIZED P ARTS LIST
Item No. Part No. Description
*1 2 **3 4 5 6 7 8 9
10
22490C
38417002
51469C 70792C 56092C 70823C 70822C
See Table A
70683C 70818C
Bracket - Filter Mounting Screw #8-18 x .50 (13mm) LG. HHSM Filter Head & Bracket Assembly Screw #8-18 x .75 (19mm) LG. PH Poly T ubing(Cut to Length) Fitting - Superseal 3/8" (10mm) Fitting - Superseal 1/4" (6mm) Filter Assembly Union - 1/4" (6mm) Elbow Adapter 3/8" x 3/8"
5
9
2
3
7
1
6
8
10 WHEN REQUIRED
FIG. 3
*Note: Bracket can be turned over to provide better fit in some models. **Item No(s). 1, 4, 6, and 7 included with item No. 3.
FIL TER LOCATION
HAC-Q
Page 297787C (Rev. D - 02/07)
HAC-BL-Q
S-D-Q
FIL TER LOCATION
FILTER
LOCA TION
SCWT-A-Q
FILTER
LOCA TION
Page 3 97787C (Rev. D - 02/07)
NOTICE
T o receive maximum benefit from your Halsey Taylor®WaterSentry® filters, note the installation dates below, and change according to the following guidelines.
Halsey T aylor® WaterSentry® VII -- Lead/Cyst Reduction Filter
Change every 1,500 gallons, or once a year -- whichever occurs first.
- - KEEP THIS SHEET IN A HANDY LOCATION - -
DA TE
INST ALLED
MODEL
(TYPE OF FIL TER)
SERVICE
PERSON
DA TE
INST ALLED
MODEL
(TYPE OF FIL TER)
SERVICE
PERSON
2222 CAMDEN COURT OAK BROOK, IL 60523
630.574.3500
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW.HALSEYTAYLOR.COM
PRINTED IN U.S.A.
Page 497787C (Rev. D - 02/07)
Loading...
+ 8 hidden pages