HACFSCDBL*D HACFSCDDBL*D HACFSCDDBLR*D HACFSCWFDBL*D HACFSCWFDDBL*D
HAC8FSCBLQ*1D HAC8FSCBLRQ*1D HAC8FSCWFBL*1D
HALSEY TAYLOR OWNERS MANUAL
BI-LEVEL BARRIER FREE COOLER
USES HFC-134A REFRIGERANT
8
32,33,35,
36,37,38,39
42
See Fig. 4 (Page 4) For
Push Bar Mechanism
40
9
10,1 1
1
46
7
44
2,3,4,5
6
41
8
9
42
65
45
19
65
45
17
20 (BL)
21 (BLR)
22 (BL)
23 (BLR)
43
45
33,34,35,
36,37,38,39
31
28,29,30
40 10,1 1
17
24,25,26
65
45
12
13
27
18
45
FIG . 1
HAC8FSCBL SHOWN
NOTE: Non-refrigerated units do not include all electrical and refrigeration components shown above. Other components and rough-in are the same as shown.
Page 1
98350C (Rev. D - 9/09)
HACFSCDBL*D HACFSCDDBL*D HACFSCDDBLR*D HACFSCWFDBL*D HACFSCWFDDBL*D
HAC8FSCBLQ*1D HAC8FSCBLRQ*1D HAC8FSCWFBL*1D
6 3/4"
172mm
18 5/8"
473mm
HANGER BRACKET
FIJADOR DE SUSPENSION
SUPPORT DE SUSPENSION
2 5/8"
67mm
39 1/2"
1003mm
C
4 1/8"
105mm
8"
203mm
31 7/8"
809mm
ORIFICIO
HAUTEUR DE
ALTURA DE LA
ORIFICE HEIGHT
BORD
CORONA
RIM HE IGHT
HAUTEUR DE
ALTURA DE LA
33"
838mm
ORIFICE HEIGHT
L'ORIFICE
12 5/16"
313mm
* ADA REQUIREMENT
* REQUISITO DE A.D.A.
* EXIGENCE ADA
27"
686mm
*
ORIFICI O
L'ORIFICE
HAUTEUR DE
ALTURA DE LA
HAC8FSCBL
18 1/16"
459mm
5 3/4"
5 3/4"
5 3/4"
146mm
1 3/8"
35mm
1 3/8"
35mm
5 3/4"
146mm
25 1/8"
638mm
20 1/8"
511mm
E
D
146mm
1 3/8"
35mm
1 3/8"
35mm
146mm
L
C
4 9/16"
116mm
E
6 1/2"
165mm
A
L
C
11/16"
18mm
F
7 1/4"
185mm
F
2 7/16"
63mm
2 9/16"
18 3/4"
476mm
13 7/8"
352mm
4 1/2"
114mm
3 1/2"
89mm
6 1/4"
159mm
B
10"
254mm
5"
127mm
65mm
20 3/8"
518mm
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
98350C (Rev. D - 9/09)
8mm (10 TROUS)
8MM (10 AGUJEROUS)
5/16" (8mm ) DIA. (10 HOLES)
37 1/2"
952mm
COBRE NO PLATEADO.
TUBE COULEUR CUIVRE NON PLAQUÉ.
UBICACIÓN RECOMENDADA P ARA EL DRENAJE DE SALIDA DE AGUA, DE 1-1/2 DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/2 DE SORTIE D’EAU.
PURGADOR DE 1-1/2 NO PROPORCIONADO**
SIPHON 1-1/2 NON FOURNI**
CAJA RECESIV A DE ALAMBRES (3) DE SUMINISTRO ELÉCTRICO
BOÎTE ENCASTRÉE D’ALIMENTA TION ÉLECTRIQUE (3) FILS
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6" (152 mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE
VENTILACIÓN DEL MUEBLE Y LA P ARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6" (152 mm) (MIN.) ENTRE LES ÉVENTS DE L ’ENCEINTE ET LE MUR.
AGUJEROS DE LAS TUERCAS DE 7/16 PARA SUJET AR LA UNIDAD A LA P ARED
FIG . 2
POSICIÓN DE ABASTECIMIENTO DE AGUA RECOMENDADA. VÁLVULA CERRADA (NO AMUEBLADO) PARA ACEPTAR 3/8" O.D. TUBO DE
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED W ATER SUPPLY LOCATION. SHUT OFF VA L VE (NOT FURNISHED) TO ACCEPT 3/8 O.D. UNPLA TED COPPER TUBE.
ENDROIT D’APPROVISIONNEMENT EN EAU RECOMMANDÉ. LA VAL VE ARRÊTÉE (NON FOURNI) POUR ACCEPTER 3/8" PO. (9,5mm)
B = RECOMMENDED LOCATION FOR W ASTE OUTLET 1-1/2” O.D. DRAIN
C = 1-1/2" TRAP NOT FURNISHED**
D = ELECTRICAL SUPPL Y (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
TROUS D’ÉCROUS 7/16 POUR FIXER L’APP AREIL AU MUR
F = 7/16 BOLT HOLES FOR F ASTENING UNIT T O WALL
Page 2