Halsey Taylor 8880 w-10245 User Manual

This fountain is certified to
NSF/ANSI 61.
GENERAL
Fully recessed fountain, non-corrosive stainless steel number 300 series with brushed satin finish. One-piece, contour-formed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water. Cuspidor may be mounted to right or left of fountain. Ideally suited for installation in high traffic areas. When properly installed, unit meets state and federal requirements as defined by the Americans with Disabilities Act for side approach.
BUBBLER
Exclusive one-piece, chrome-plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting. Cuspidor flushing jet operates when drinking fountain is actuated.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/2" tube outlet for 1-1/2" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front, contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. Cooler shall comply with ANSI 117:1 and ADA for side approach only. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice. See Halsey Taylor website for most current spec sheet.
Standard Finish is Stainless Steel
Important: When using 8880 drinking fountain
in conjunction with cuspidor, specification should state “with Cusidor connection for bypass to Cuspidor.” Use 8880 w/10245 when
ordering.
Optional Accessories (extra cost)
Glass Filler (factory installed ­No. 2408 style glass filler only).
Vandal-Resistant Kit
Easy-Flex™Bubbler
Each 8880 w/ 10245 consists of 4 cartons of the following:
Fountain & Miscellaneous Parts Cuspidor & Miscellaneous Parts Two Mounting Frames
Trap and service stop not included.
S
hipping weight: 66 lbs.
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
D2 / 8-2007
MODEL 8880 w/10245
Fountain and Cuspidor
Fully Recessed
halseytaylor.com
JOB NAME:
ENGINEER/CONTRACTOR NAME:
APPROVAL:
DATE:
*
* For parallel approach only
Printed in the U.S.A.
8880 w/10245
Fully Recessed Fountain and Cuspidor
(CONTINUED)
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing and for size of wall cut out. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.)
Installation requires trap to be installed in wall. A service supply stop must be installed at the fountain inlet line. Trap and service stop not included.
NOTE: Supply line between fountain and cuspidor
to be furnished and installed by contractor.
OPERATING PRESSURES
Supply water-105 psi maximum. Cuspidor water pressure must be 40 lbs. minimum.
10245 CUSPIDOR
CUSPIDOR CAN BE MOUNTED ON LEFT
(AS SHOWN) OR RIGHT OF FOUNTAIN
8880C FOUNTAIN
LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8" O.D. UNPLATED COPPER TUBE CONNECT
STUB 1-1/2" (38mm) OUT FROM WALL SHUT OFF BY OTHERS
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN