7120 FTN
Halsey Taylor Owners Manual
Model: 7120 Fountain
Marblyte Fountain
Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION
FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO
A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE
IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER
MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE
OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
FIG. 1
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATER FLOW
DIRECTION
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
Page 1
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
TUBE IS SECURED
TUBE IS SECURED
IN POSITION
IN POSITION
B CA
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
FIG. 2
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
RELEASE TUBE
RELEASE TUBE
96974C (Rev. N - 08/18)
7120 FTN
MOUNTING BOLTS &
7 MOUNTING BOLTS,
WASHER REQUIRED TO
MINIMIZE BREAKAGE OF
FOUNTAIN ( TYPICAL ALL
WASHERS NOT INCLUDED).
18 1/16"
459mm
DETAIL NO. 1
2 15/16"
74mm
37 3/4"
959mm
SEE DETAIL NO. 1
8"
8"
ADA
27"
685mm
REQUIREMENT
33 3/4"
857mm
A
16"
406mm
203mm
FINISHED FLOOR
3"
76mm
203mm
B
16"
406mm
FIG. 3
96974C (Rev. N - 08/18)
Page 2
32 5/8"
829mm
32 1/4"
819mm
32 7/8"
835mm
30 7/8"
784mm
28 1/4"
718mm
LEGEND
A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS
B = WATER OUTLET 1-1/4" O.D. DRAIN - STUB OUT FROM WALL 1" (25mm)