6028 FOUNTAIN
Halsey Taylor Installation Manual
Model 6028
Countertop Fountains
Installer
To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these
instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
1. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/2" O.D. tube. Contractor to supply waste
trap and service stop valve in accordance with local code.
2. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all
foreign matter before being connected to fountain. This fountain is manufactured in such a manner
that it does not in any way cause taste, odor, color, or sediment problems.
3. Connect the 3/8" O.D. unplated copper water line from the fountain to the service stop valve (see
figs.3 and 4). DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO
THE O-RINGS MAY RESULT.
4. These products are designed to operate on 20 psig to 105 psig supply line pressure. If inlet pressure
is above 105 psig, a pressure regulator must be installed in the supply line. Any damage caused by
reason of connecting this product to supply line pressures lower than 20 psig or higher than 105 psig
is not covered by warranty.
PAGE 1
97274C (Rev. C - 7/04)
6028 FOUNTAIN
STREAM HEIGHT ADJUSTMENT: Stream height is factory set at 35 PSI.
If supply pressure varies greatly from this, remove items 16 & 17
(see Fig.2) and adjust screw on item 24. Clockwise adjustment
will raise stream and counter-clockwise adjustment will lower
stream. For best adjustment, stream should hit basin approx.
6-1/2" from bubbler.
FIG. 1
CORRECT STREAM HEIGHT
17 20
2
1516 24
FIG. 2
OPERATION OF QUICK CONNECT FITTINGS
Simply Push In Tube
To Attach
AB C
Tube Is Secured In
Position
Push In Collet To
Release Tube
Pushing Tube In Before
Pulling It Out Helps To
Release Tube.
97274C (Rev. C - 7/04)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATER FLOW
DIRECTION
FIG. 3
FIG. 4
PAGE 2
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)