Face Mounted Fountain
(CONTINUED)
MOUNTING INSTRUCTIONS
• Establish the rim height of fountain to be
mounted.
• Refer to rough-in for location of plumbing
through wall.
• Mount fountain hanger on wall as shown.
• Locate trap (not furnished) on waste line —
see rough-in for proper distance from wall.
• Install service valve (not furnished) on building
water supply line.
• Hang fountain on wall and adjust hanger
(if necessary) for proper fit to trap.
• Connect fountain supply line to service valve.
• Tighten drain plug into fountain, and secure
fountain to wall with screws (furnished).
• Open service valve fully and check for water
leaks.
• Stream height is factory set 45-50 psi. If water
pressure varies greatly from this, adjust
automatic stream regulator (on valve body) to
provide drinking stream approx. 11⁄2” above
projector guard.
CAUTION – Fountain must be securely
bolted to wall
OPERATING PRESSURES:
Supply water-105 psi maximum
FRONT VIEW
SIDE VIEW
❏ 5905
FRONT VIEW
SIDE VIEW
❏ 5905AC
Installation Instructions for 5905AC
1. Frame Wall
2. Remove bottom cover from fountain and
save the screws. Assemble push rod to fountain.
(push rod provided with freeze-resistant box)
3. Install the fountain using bolts and washers
(not provided). Tighten securely.
4. Attach drain tube to fountain and cut to
required length using the freeze-resistant box
as a guide. 1-1/4" waste outlet located in
freeze-resistant valve system.
5. Install freeze-resistant box behind non-
freezing wall - see box instructions.
6. Install a service stop (not provided) and
make water supply connection from the stop to
the strainer in the freeze-resistant box. DO NOT
SOLDER TUBES INSERTED INTO THE
STRAINER AS DAMAGE TO THE O-RINGS
MAY RESULT.
7. Connect fountain water line to freeze-resistant
box - see box instructions. Replace bottom
cover. 3/8" O.D. tubing to freeze-resistant box.
CAUTION – Fountain must be securely
bolted to wall