Halsey Taylor 5801VR User Manual

This fountain is certified to
NSF/ANSI 61.
GENERAL
Semi-recessed fountain, one-piece, non-corrosive stainless steel number 300 series with brushed satin finish. Contour­formed basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
BUBBLER
Vandal-resistant bubbler is one-piece, chrome­plated, with integral hood guard design to prevent contamination from other users, air­borne deposits and tampering.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
INLET STRAINER
Easily cleaned in-line strainer screen traps particles of 140 microns or larger before they enter the waterway.
WATER INLET
3/8" O.D. Tubing
DRAIN OUTLET
1-1/2" tube outlet for 1-1/2" slip joint connection.
SUGGESTED SPECIFICATIONS
Fountain shall include pushbutton on the front, contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be chrome-plated vandal-resistant type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice. See Halsey Taylor website for most current spec sheet.
Standard finish is Stainless Steel
Optional Accessories (extra cost)
Glass Filler (factory installed ­No. 2408 style glass filler only).
Easy-Flex™Bubbler
Trap and service stop not included.
Shipping weight: 19 lbs.
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
D5 / 1-2005
MODEL:■5801VR Fountain
Fountain
Semi-Recessed
Vandal-Resistant
www.halseytaylor.com
Printed in the U.S.A.
Semi-Recessed Fountain
(CONTINUED)
MOUNTING INSTRUCTIONS
Refer to diagrams for rough-in of plumbing and for size of wall cut out. Final check for leaks and correct functions of fountain should be made. (For details see the installation instructions.)
Installation requires trap to be installed in wall. A service supply stop must be installed at the fountain inlet line. Trap and service stop not included.
OPERATING PRESSURES
Supply water-105 psi maximum
LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB
1-1/2" (38mm) OUT FROM WALL SHUT OFF BY OTHERS B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN C = WALL SCREW HOLES
SIDE VIEW