Halsey Taylor 56191C Service Manual

Halsey Taylor® Aqua Sentry
Lead, Cyst, Chlorine Taste, Odor & Particulate Reduction Filter
Water T reatment Unit P/N 56191C
FOR COMMERCIAL USE ONLY
PERFORMANCE DA T A SHEET
IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It is recommended that, before purchasing a water treatment unit, you have your water supply tested to determine your actual water treatment needs.
NOTICE: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
This water filter should be installed and used in compliance with any state or local laws and regulations.
CAUTION: Use on cold water line only . Do not allow inst alled filter to freeze.
RECOMMENDED USE CONDITIONS
Capacity
750 Gallons
6 Month Maximum
Maximum Pressure 125 PSI (8.62 bar)
Flow Rate Temperature
0.5 GPM
40-100° F (5-38° C)
Minimum Pressure 20 PSI (1.4 bar)
NOTE: Performance will vary depending on local water conditions.
Instructions For Installing Replacement Filters
1. Turn off water supply and dispense water to relieve water pressure.
2. Mount filter in a suitable location with water flow in direction indicated on filter. This filter is most effective when installed so that water flows through the filter in a downward direction. Do not support the filter using the inlet or outlet tubing. A plastic snap-in bracket, p/n 56190C, is available that can be screwed onto a flat surface.
3. Connect the cold water supply to the filter through a shut-off valve and 1/4" O.D. tubing (supplied by the installer). For ease of servicing, the shut-off valve should be located within easy reach of the filter.
Note: The inlet and outlet fittings supplied as a part of the filter are John Guest fittings that accept 1/4" O.D. tubing. They may be used with copper , stainless steel or semirigid nylon or polypropylene tubing with a rated working pressure equal or greater than encountered in application. Do not use soft braided tubing.
4. Caution: If supply pressure will ever exceed 125 psi, install a pressure regulator to limit the inlet pressure to the filter to 20 - 125 psi range.
To make connections to the filter, push tube end in the fittings past the o-ring to a positive stop - approximately 5/8". Ends of tubing must be cut square and free of burrs, sharp ends or scratches that could cut or nick the o-rings or cause a leak.
5. Turn water supply on and check fittings for leaks.
6. Dispense approximately 1 gallon of water to flush any particulate from the filter.
Your Authorized Representative
Buyer
Seller
The Halsey T aylor® Aqua Sentry is warranted to be free from defect s in material and workmanship for a period of one year from the date of installation. W arranty is limited to repair or replacement of defective component.
97975C (Rev. F - 11/08)PAGE 1
The Halsey T aylor® Aqua Sentry filter has been tested according to NSF/ANSI 42 and 53 for reduction of the substances listed below . The concentration of the indicated substance in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
Maximum
Maximum
Permissible
Permissible
Influent Challenge
Influent Challenge
ConcentrationSubstance
ConcentrationSubstance
Standard 42
Standard 42
Particulates
Particulates (0.5-<1m)-Class 1
(0.5-<1m)-Class 1 Standard 53
Standard 53
Flow rate = 0.5 gpm (1.9 Lpm); Capacity = 750 gallons (2839 L) or 6 months
Flow rate = 0.5 gpm (1.9 Lpm); Capacity = 750 gallons (2839 L) or 6 months
at least 10,000
at least 10,000
particles/mL
particles/mL
Product Water
Product Water
Concentration
Concentration
Reduction
Reduction
Requirements
Requirements
Minimum
Minimum
Reduction
Reduction
Average
Average
Reduction
Reduction
95.7%84.3%≥ 50%2.0 mg/L ± 10%Chlorine Taste & Odor
95.7%84.3%≥ 50%2.0 mg/L ± 10%Chlorine Taste & Odor
99.5%98.9%≥ 85%
99.5%98.9%≥ 85%
99.99%99.99%99.95%Minimum 50,000/LCysts
99.99%99.99%99.95%Minimum 50,000/LCysts
99.3%99.3%0.010 mg/L0.15 mg/L ± 10%Lead (pH 6.5)
99.3%99.3%0.010 mg/L0.15 mg/L ± 10%Lead (pH 6.5)
99.4%98.8%0.010 mg/L0.15 mg/L ± 10%Lead (pH 8.5)
99.4%98.8%0.010 mg/L0.15 mg/L ± 10%Lead (pH 8.5)
Test Conditions
Test Conditions
= as noted for filter systemFlow Rate
= as noted for filter systemFlow Rate = 60 psi (4.1 bar)Inlet Pressure
= 60 psi (4.1 bar)Inlet Pressure
7.5 ± 1pH
7.5 ± 1pH = 68°F ± 5°F (20°C ± 2.5°C)Temperature
= 68°F ± 5°F (20°C ± 2.5°C)Temperature
Operating Requirements
Operating Requirements
= 20-125 psi (1.4-8.62 bar)Pressure
= 20-125 psi (1.4-8.62 bar)Pressure = 40-100°F (4.4-37.8°C)Temperature
= 40-100°F (4.4-37.8°C)Temperature = 5 NTU Max.Turbidity
= 5 NTU Max.Turbidity
56191C Replacement Lead/Cyst Reduction Filter
2222 CAMDEN COURT OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
97975C (Rev. F - 11/08) PAGE 2
FOR REPLACEMENT FILTER, PLEASE CALL 1.630.574.3500