Halsey Taylor 4715 FR User Manual

This fountain is certified to
NSF/ANSI 61.
GENERAL
Pedestal, Endura™steel fountain with textured powder coat finish and E-Coat immersion for year-round beauty with minimum maintenance. The E-Coat immersion process coats the outside and inside of the fountain for the ultimate in corrosion protection. Contour­formed stainless steel basin with rounded corners and edges reduces splatter, insures proper drainage and prevents standing waste water.
FREEZE-RESISTANT VALVE SYSTEM
Freeze-resistant valve designed for ground installation 18" below the frost line. 60" of access tubing provided with the freeze-resistant valve system. The length of the tubing can be adjusted in the field for lesser frost depths.
BUBBLER
Exclusive one-piece, vandal-resistant, chrome­plated two-stream mound-building bubbler with non-removable anti-squirt feature and integral hood insures a satisfying drink of water.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does not require grasping or twisting.
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent tampering. Unit resists corrosion and liming. A constant stream height is automatically maintained under line pressures that vary from 20 to 105 psi.
WATER INLET
3/8" female NPT fitting
DRAIN OUTLET
1-1/4" tube outlet. Drain requirements are detailed in owner’s manual.
ACCESS PANEL
Manufactured of heavy-gauge steel with vandal-resistant screws. Provides access for easy hook-up of all plumbing connections.
SUGGESTED SPECIFICATIONS
Fountain shall be upright pedestal, Endura
Steel with powder coat epoxy finish. Shall include pushbutton on the front. Shall include stainless steel contour-formed basin to eliminate splashing and standing water, and shall have rounded corners and edges. Projector shall be two-stream, mound-building type with integral hood guard and anti-squirt feature. The manufacturer shall certify the unit to meet the requirements of NSF/ANSI 61, and the Safe Drinking Water Act.
Note: Continued product improvement makes specifications subject to change without notice. See Halsey Taylor website for most current spec sheet.
Standard finish is Evergreen textured powder-coat Endura II
Each 4715 FR consists of 2 cartons of the following:
Fountain
Freeze-Resistant Valve System
Service stop not included.
Shipping weight: 71 lbs.
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
D18 / 8-2007
MODEL 4715 FR
Pedestal Fountain
Endura™ Steel
Freeze-Resistant
halseytaylor.com
JOB NAME:
ENGINEER/CONTRACTOR NAME:
APPROVAL:
DATE:
Printed in the U.S.A.
4715 FR
Freeze-Resistant Endura
Steel Pedestal Fountain
(CONTINUED)
MOUNTING INSTRUCTIONS and PLUMBING CONNECTIONS
Site and drainage excavation is required for fountain installation. Refer to owner’s manual for site preparation details. Provide solid, well-drained surface to mount pedestal fountain (concrete pad recommended). (4) 1⁄2" anchor bolts (not included) should be attached firmly to mounting surface in order to secure fountain. Refer to rough-in diagram and be sure to allow an opening for the freeze-resistant valve in the ground as shown in the installation instructions that accompany the fountain. Refer to local codes for any additional requirements.
NOTE: Fountain is not furnished with service valve. Assemble fountain to prepared site and mounting pad.
Position pedestal over plumbing and secure base to anchor bolts. Remove access panels and connect supply and water lines. Turn on water supply and check for leaks. Refer to owner’s manual for detailed instructions.
OPERATING PRESSURES
Supply water - 20 psi minimum to 105 psi maximum.