![](/html/41/4161/4161a09a0021a219a0a213d0c0e4f858910d887027fe37fccf60fa3b218489d3/bg1.png)
4705 FR FTN
Halsey Taylor Owners Manual
Freeze Resistant Wall Mounted Steel Fountain
INSTALLER
Halsey Taylor Fountains are among the easiest to install Fountains on the market today. To assure you
install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE
STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING,
ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the
Fountain for future reference. This Freeze Resistant Fountain is shipped in two separate cartons. The
second carton(s) contains the Freeze Resistant Package(s) HTFRB1 that are installed on an interior
heated wall. The interior space must maintain a minimium temperature of 50° F (10° C). Refer to the
Freeze Resistant Package for the rough-in dimensions for installation.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON.
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM.
PAGE 1
97799C (Rev. D - 5/04)
![](/html/41/4161/4161a09a0021a219a0a213d0c0e4f858910d887027fe37fccf60fa3b218489d3/bg2.png)
97799C (Rev. D - 5/04)
4705 FR FTN
PAGE 2
4705 FREEZE RESISTANT STEEL FOUNTAIN
MOUNTING HOLE AND ACCESS HOLE LAYOUT
LEGEND
A = MOUNTING HOLE LOCATIONS (4), (1/2" DIA. BOLTS NOT PROVIDED).
B = 7/8" DIA. (22mm) HOLE FOR WATER SUPPLY TUBE.
C = 7/8" DIA. (22mm) HOLE FOR OPERATING CABLE.
D = 1-3/4" DIA. (44mm) HOLE FOR WASTE LINE.
FIG. 1
![](/html/41/4161/4161a09a0021a219a0a213d0c0e4f858910d887027fe37fccf60fa3b218489d3/bg3.png)
97799C (Rev. D - 5/04)
4705 FR FTN
PAGE 3
4705 FREEZE RESISTANT STEEL FOUNTAIN
ROUGH-IN DRAWINGS
1. Wall should already be framed for the fountain using dimensions shown in Fig. 1. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1. and ADA (Framing shown for reference only).
2. Remove bottom cover from fountain and save screws.
3. Install the fountain using bolts and washers (not provided). Tighten securely.
4. Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide.
5. Install freeze-resistant box - see box instructions.
6. Replace bottom cover.
FIG. 2