Halo Lighting System LV108, LV104, LV106, LV102 User Manual

LV501
Power Supply
60W max
10'
Cord
2', 4', 6', 8' Surface Channel
2', 4', 6', 8' Surface Channel
LV502 Power Supply 150W max
NOTE: LV502 Canopy can be placed anywhere along channel to utilize existing power sources.
120V Supply
2', 4', 6', 8' Surface Channel
LV503 150W max
Low Voltage Feed
LV204
LINEA™by HALO
®
Channels
®
by HALO
LINEA
LV102, LV104, LV106, LV108
• LV102–2' Channel. Actual length 20 3/16" (513mm) Color Codes: P, MB
• LV104–4' Channel. Actual length 44 3/16" (1122mm) Color Codes: P, MB
• LV106–6' Channel. Actual length 68 3/16"(1731mm) Color Codes: P, MB
• LV108–8' Channel. Actual length 92 3/16" (2341mm) Color Codes: P, MB
SURFACE CHANNEL
Surface Channel
Surface-mount channel is used when minimal size and weight are desirable. Typical applications for surface-mount are under-cabinet, in-cabinet, cove and strip lighting. Surface-mount consists of a housing with two square copper conductors.
Size
Linea surface channel is 3/8" (9.5mm) high and 3/4" (19mm) wide.
Finishes
White (P), Black (MB)
Connectors
Surface channel connectors and feed points allow almost unlimited configurations. Channels may be field cut to any length. Channels can be mechanically and electrically connected by straight, right-angle and flexible joiners. Electrical feeds to surface channel are made using the end feed, conduit feed, J-box feed or T-bar feed. Feeds and joiners push into the end of the channel and are secured with a single screw. Electrical connections are assured by compression-type, nickel­plated brass terminal blocks.
Grounding
Low-voltage lighting systems do not require grounding when used with LV500 series isolated power supplies.
Polarity
The lampholder adapter may be inserted in either orientation, simplifying installation and allowing greater than 360º rotation for maximum fixture adjustment.
Specifications
Surface-mount channel consists of a thermal plastic housing with two 10AWG nickel-plated copper conductors. Electrical capacity is: 12V, 25amp, 300 Watt maximum 24V, 25amp, 600 Watt maximum
PLANNING A LINEA LAYOUT
Surface Channels
NOTE: Surface Channel may be up to 20’ with electronic power supplies and 40’ with magnetic power supplies.
LV501
LV502
Starting and Adding to Surface Channel Runs with Magnetic Power Supplies
Magnetic
Power Supply
120V or 277V Supply 12V or 24V Feed
Power Supplies Feed Points Channels Joiners Additional Channels
LV503 LV506 LV507 LV508 LV509
Feed Point
LV200 J-Box Feed LV201 End Feed LV204 Conduit Feed LV206 T-Bar Feed
LV206 T-Bar Feed with up to three additional TB206 Terminal Blocks
CHANNEL
2’ Surface Channel 4’ Surface Channel 6’ Surface Channel 8’ Surface Channel
Joiner
LV202 Straight Joiner
LV203 Right-Angle Joiner
LV205 Flexible Joiner
LV503
ADDITIONAL CHANNEL
2’ Surface Channel 4’ Surface Channel 6’ Surface Channel 8’ Surface Channel
278
COOPER LIGHTING
Loading...