D E S C R I P T I O N
A lampholder designed for use with two energy efficient 39W twin tube compact fluorescent lamps. For use with single circuit Halo and Lazer-by-Halo track systems. Ideal for wallwashing in retail stores, public areas and other commercial spaces. For ceiling mounted track only. Not suitable for use with four circuit track.
Catalog #
Project
Comments
HALO
Type
ate
D
®
S P E C I F I C A T I O N F E A T U R E S
...
uick Lock Adapter
A
Q
Trac plug attaches anywhere along Halo Power-Trac. Two position conductor allows use in single circuit and either circuit of two circuit track. Visual polarity line assures proper grounding. Large bearing surface provides extra stability.
...
oke
B
Y
Pre-tensioned adjustment mechanism allows lampholder to pivot vertically from 0° to ±80° as well as rotate horizontally. Unobtrusive angle
.. .. .. .. .
B
E
.. .. .. .. .
C
W
indicators are provided to enable consistent aiming.
...
C
Housing
Solid aluminum extrusion with die-cast aluminum end caps. No exposed rivets or screw heads. Standard electronic ballast provides energy efficiency, light weight and silent operation.
...
eflector
D
R
Specular reflector provides precise optical control and low iridescence.
.. .. .. .. .. . .. .. .. .. ..
A
Prepared by
...
E
Louver (Optional)
One piece injection molded louvers with unique curved profile available in Low Iridescent Specular Clear, White or Black. The parabolic louvers provide optimal brightness control and improve aesthetic appeal. Louver and reflector form a continuous light path with no gaps or obstructions.
L a bel s
UL listed and CSA certified for
L3239E
3 9 W T W I N T U B E
C O M P A C T
F L U O R E S C E N T
L A M P H O L D E R
P o wer - T r a c
®
L
.. .. .. .. .. . .. .. .. ..
D
.. .. .. .. .. . .. .
E
O R D E R I N G I N F O R M A T I O N
S A M P LE NU M B E R : L 3 2 39E P - L V R 3 2 3 9 S C
C o m p le t e u n it c o n s is t s o f La m p h o l d e r an d F in i s h ( Lo u v e r is o p t i on a l ) .
L a mph o l d e r
F i nis h
L o uve r ( O p t i o nal )
L3239E
L3239E=39W
L3239E
For use with: Two 39W twin Tube Compact Fluorescent Lamps
L =18 15/16" [481mm] W =6" [152mm] E =8 1/16" [205mm]
P=White MB=Black
LVR3239P=White LVR3239MB=Black LVR3239SC=Specular
NOTES:
For additional options please consult factory.
Sconce Energy Data Lamp(s): (2) 39W Triple Tube 4-pin Ballast Type: Electronic 120V Input Watts: 75 Line Amps: 0.63 Power Factor: >.99 THD: <10% (15°F) Min. Starting Temp: 50° F (10°C) Sound Rating: A
L3239
ADV990368
5/08
CO OP ER LIG HT ING
P H O T O M E T R I C S
L 3 2 3 9 E
Test No. H20061
L3239E-LVR3239SC Specular Louver
amp=(2) 39W TT
L
umens=2,850
L
5° Aiming Angle
4
Test No. H20063
L3239E-LVR3239P White Louver
Lamp=(2) 39W TT Lumens=2,850 45° Aiming Angle
Test No. H20062
L3239E-LVR3239MB Black Louver
Lamp=(2) 39W TT Lumens=2,850 45° Aiming Angle
Notes:
• Illuminance values for multiple fixtures are based upon the center two units of a four unit array. Footcandle values are centerline of fixtures and centered between fixtures. 1 footcandle = 10.76 lux. 1 foot(') = 304.8mm.
• Illuminance values are cosine corrected initial values with no contribution from inter reflections from other room surfaces. Total illumination may increase from contributions from other surfaces.
• Changing fixture spacing will affect illuminance level.
Existing Spacing New Spacing
i n gle F i x t u r e 3' F r o m W a l l
S
DD
1 2 3 4 5 6 7 8 9
10
Distance From Fixture Along Wall
I 1' 2' 3' 4' 5' 6'
104 84 50 24 12 52
87 73 48 26 14 74 55 49 35 22 13 84
3 30 24 17 11 74
3 20 19 15 12 864 12 11 10 8653
876543
8 5554432 4443322
332222
3
S i ngl e F i x t u r e 4 ' F r o m W a ll
D
D
1 2 3 4 5 6 7 8 9
10
Distance From Fixture Along Wall
I 1' 2' 3' 4' 5' 6'
9 52 37 23 13 74
5 54 49 37 24 14 95 44 41 32 22 14 96 31 29 24 18 13 96
1 20 17 14 10 75
2 14 14 12 10 864 10 10 97654
765543
7
544433
5 4433322
S i ngl e F i x t u r e 3 ' F r o m W a ll
D
D
1 2 3 4 5 6 7 8 9
10
Distance From Fixture Along Wall
I 1' 2' 3' 4' 5' 6'
03 80 44 20 942
1
88 71 43 22 11 63 56 48 33 20 11 63 33 30 22 15 963
0 18 15 11 753
2
2 11 10 8643
1
8775432 5554332 4433222 3332221
S i ngl e F i x t u r e 4 ' F r o m W a ll
DD
1 2 3 4 5 6 7 8 9
10
Distance From Fixture Along Wall
I 1' 2' 3' 4' 5' 6'
58 50 33 19 11 63 54 48 34 21 12 74 45 40 30 20 12 85 32 29 23 16 11 75 21 20 17 13 964 15 14 12 9754 10 987643
7765433 5544332 4433322
S i ngl e F i x t u r e 3 ' F r o m W a ll
DD
1 2 3 4 5 6 7 8 9
10
Distance From Fixture Along Wall
I 1' 2' 3' 4' 5' 6'
86 64 33 14 521 75 60 35 17 832 48 41 27 15 842 29 26 19 12 742 17 16 12 9642 10 10 86432
6654322 4443321 3332211 2222211
S i ngl e F i x t u r e 4 ' F r o m W a ll
DD
1 2 3 4 5 6 7 8 9
10
x Average Table Fc Level
Distance From Fixture Along Wall
I 1' 2' 3' 4' 5' 6'
48 40 25 14 732 46 40 27 16 952 38 34 25 16 953 27 25 19 13 953 18 17 14 10 753 13 12 10 8643
8876432 6654332 4443322 3332221
u l tip l e F i x t u res 3 ' D i s t a nce F r o m W a ll
M
I–––––– 3' ––––––II–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––I
DD
155 150 155 127 104 127 115 71 115 109 49 109
1
42 141 142 115 103 115 101 74 101 94 53 94
1
2
104 105 104 83 80 83 71 61 71 64 47 64
3
71 72 71 56 56 56 47 45 47 42 35 42
4
7 48 47 38 38 38 32 31 32 28 26 28
4
5
32 33 32 26 26 26 22 22 22 19 19 19
6
22 23 22 19 19 19 16 16 16 14 14 14
7
16 17 16 14 14 14 12 12 12 10 10 10
8
12 12 12 10 11 10 999 8 88
9
99 9 88 8 7 7 7 6 6 6
0
1
pacing Between Fixtures
S
M u lti p l e F i x t ure s 4 ' D i s t ance F r o m W a l l
I–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––II–––––– 7' ––––––I
DD
6 82 86 74 62 74 67 46 67 64 35 64
8
1
84 84 84 72 66 72 64 50 64 60 38 60
2
75 75 75 63 60 63 56 47 56 51 37 51
3
59 59 59 49 48 49 43 39 43 39 32 39
4
4 45 44 37 37 37 32 31 32 29 25 29
4
5
33 33 33 28 28 28 24 24 24 21 20 21
6
24 25 24 21 21 21 18 18 18 16 15 16
7
8 18 18 15 16 15 13 13 13 12 12 12
1
8
3 14 13 12 12 12 10 11 10 999
1
9
10 11 10 9 10 9888 777
10
Spacing Between Fixtures
M u lti p l e F i x t ure s 3 ' D i s t ance F r o m W a l l
I–––––– 3' ––––––II–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––I
DD
46 134 146 122 92 122 112 61 112 107 41 107
1
1
135 129 135 111 92 111 99 65 99 94 45 94
2
99 97 99 79 72 79 69 54 69 63 41 63
3
67 67 67 53 52 53 45 40 45 41 32 41
4
5 45 45 36 36 36 30 29 30 27 23 27
4
5
0 31 30 25 25 25 21 20 21 18 17 18
3
6
21 22 21 18 18 18 15 15 15 13 13 13
7
15 16 15 13 13 13 11 11 11 10 10 10
8
11 12 11 10 10 10 89 8 7 77
9
99 9 88 8 77 7 66 6
0
1
Spacing Between Fixtures
M u lti p l e F i x t ure s 4 ' D i s t ance F r o m W a l l
I–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––II–––––– 7' ––––––I
DD
80 73 80 70 54 70 64 40 64 61 30 61
1
80 76 80 69 59 69 63 44 63 60 33 60
2
71 69 71 60 54 60 54 42 54 50 33 50
3
6 55 56 47 44 47 41 35 41 38 28 38
5
4
42 42 42 35 34 35 30 28 30 27 23 27
5
31 31 31 26 26 26 23 22 23 20 18 20
6
23 23 23 19 19 19 17 16 17 15 14 15
7
17 17 17 15 15 15 13 13 13 11 11 11
8
13 13 13 11 11 11 10 10 10 999
9
10 10 10 99 9 8 8 8 7 7 7
10
Spacing Between Fixtures
M u lti p l e F i x t ure s 3 ' D i s t ance F r o m W a l l
I–––––– 3' ––––––II–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––I
DD
114 101 114 100 67 100 90 43 90 87 27 87
1
110 104 110 91 73 91 82 50 82 78 33 78
2
81 80 81 65 58 65 57 43 57 53 31 53
3
55 55 55 43 42 43 37 32 37 33 25 33
4
37 37 37 29 29 29 25 23 25 22 19 22
5
24 25 24 20 20 20 16 16 16 14 13 14
6
17 17 17 14 14 14 12 12 12 10 10 10
7
12 12 12 10 10 10 99 9 8 78
8
99 9 88 8 7 7 7 6 6 6
9
77 7 66 6 5 5 5 5 5 5
10
Spacing Between Fixtures
M u lti p l e F i x t ure s 4 ' D i s t ance F r o m W a l l
I–––––– 4' ––––––II–––––– 5' ––––––II–––––– 6' ––––––II–––––– 7' ––––––I
DD
62 54 62 55 39 55 51 28 51 49 20 49
1
64 60 64 55 45 55 51 33 51 48 24 48
2
58 56 58 50 43 50 45 33 45 42 25 42
3
46 45 46 38 35 38 34 28 34 31 22 31
4
34 34 34 29 28 29 25 22 25 22 18 22
5
25 25 25 21 21 21 18 17 18 16 15 16
6
19 19 19 16 16 16 14 13 14 12 11 12
7
14 14 14 12 12 12 10 10 10 99 9
8
10 11 10 999 888 77 7
9
888 777 666 555
10
Spacing Between Fixtures
Distance From Wall
DD=Distance Down
From Ceiling
Spacing Between
Note: Specifications and Dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADV990368