Instruction Manual
Questions?/¿Preguntas? 1-800-334-6871 ConsumerProducts@
cooperlighting.com
/Instrucciones
PACKAGING CONTENTS/CONTENIDO DEL PAQUETE
A. Light fixture
Appareil d’éclairage
Accesorio
B. Mounting bracket
Support de montage
Soporte de montaje
C. Gasket
Joint
Junta
D. (2) #6-32 x 3/4 in. and (2) #8-32 x 3/4 in. junction box screws
(use the size that fits your junction box)
(2) vis nº 6 de 32 x 3/4 po et 2 vis nº 8 de 32 x 3/4 po pou
boîtier de jonction (choisissez la dimension convenant
à votre boîtier de jonction)
(2) Tornillos #6-32 x 3/4 pulg. y (2) tornillos #8-32 x 3/4 pulg.
para montaje de la caja de conexión (utilice el tamaño que mejor
se adecue a su caja de conexión)
FSL503TB
FSL503TW
E. Adapter Plate Kit
Plaque adaptatrice trousse
Placa daptadora equipo
F. Support hook
Crochet
Gancho de soporte
ENGLISH
ITEMS REQUIRED
(Purchase separately)
• Phillips screwdriver
• Weatherproof silicone caulk
IMPORTANT SAFETY INSTRUCTIONS
When using product, basic precautions should always be followed, including the following:
• Heed all warnings, including below warnings AND those included on product.
• Save these instructions and warnings.
• For outdoor use only.
• cULus LISTED for wet location.
• Disassembling your fixture will void the warranty.
• Your fixture is prewired and preassembled for easy installation.
• Read and follow these instructions.
• Risk of fire/electric shock. If not qualified, consult an electrician.
• Disconnect power at fuse or circuit breaker before installing or servicing.
CAUTION
• Connect fixture to a 120-277 volt, 50/60 Hz power source. Any other connection voids
the warranty.
• Fixture should be installed by persons with experience in household wiring or by a
qualified electrician. The electrical system, and the method of electrically connecting
the fixture to it, must be in accordance with the National Electrical Code and local
building codes.
• Fixture designed for wall or eave mount to a junction box only. Mount fixture to a
grounded, recessed-mounted standard junction box marked for use in wet locations.
Fixture can be mounted to an outdoor rated surface mount junction box or when used
with the included adaptar plate kit. See kit instructions for proper installation methods.
• This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
G. (2) #8-32 x 1-1/4 in. cover
mounting screws
(2) vis de protection nº 8
de 32 x 1-1/4 po
(2) Tornillos #8-32 x 1-1/4 pulg.
de montaje de la cubierta
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: FCC Regulations state that any unauthorized changes or
modifications to this equipment not expressly approved by the manufacturer
could void the user’s authorization to operate this equipment.
SAVE THESE INSTRUCTIONS.
H. (2) Decorative screw cover caps
(2) cache-vis décoratifs
(2) Cubiertas tapatornillos decorativas
FOR BEST RESULTS
• Install light 8-16 feet above the ground.
• When installing two fixtures on one switch,
make sure the switch is rated for at least a
1 A inductive load.
1
13 in.
7 in.
ADJUSTING THE COLOR
TEMPERATURE (CCT)
• This product features selectable white color
tuning. Choose between three preset light colors
on the center dial of the base housing before,
during or after installation (fig. 2):
• These settings are designated by the abbreviations
located on the center dial on the base housing
(fig. 2):
3K = 3000K CCT, or soft white
4K = 4000K CCT, or neutral white
[factory default]
5K = 5000K CCT, or daylight
• Use a flathead or Phillips head screwdriver to rotate the
dial so the arrow points toward the desired setting.
• DO NOT USE a power tool or over-rotate the dial.
2
MOUNTING AND WIRING YOUR FIXTURE
WARNING: Risk of electric shock. Disconnect
power at fuse or circuit breaker before installing
or servicing.
NOTE: Fixture can be wall or eave mounted (Fig. 3).
NOTE: Coverplate mounts to recessed mounted
standard junction boxes (Fig. 4). Junction box must be
at least 1-1/2 inch in depth for proper installation for
recessed mount application. For surface mount junction
box installation, refer to installation instructions included
with the adaptar plate kit (E).
RECESSED JUNCTION BOX MOUNT
3
Wall mount
Eave mount
13 in.
1
FIXTURE BOXES
1. Line up the holes on the mounting bracket (B) with
the holes on your junction box. Using either (2) #6
screws or (2) #8 screws (D) (depending on size of
the holes in your junction box), attach the mounting
bracket (B) to your junction box (Fig. 5).
2. Thread fixture wires through mounting bracket (B)
(Fig. 5).
3. Hang one end of the support hook (F) onto the
mounting bracket guide tabs and hang the light
fixture on the other end of the support hook (Fig. 6).
4. Thread fixture wires through the gasket (C) and
connect fixture black wire to house black wire,
fixture white wire to house white wire, and fixture
ground wire to house ground wire using the
attached quick connectors (Fig.8).
5. Remove support hook (F) and attach fixture (A) to
the mounting bracket (B) using (2) #8 x 1-1/4 in.
screws (D) provided. Be sure no loose wires remain
sticking out from underneath the coverplate. Insert
the decorative screw cover caps (H) into the screw
holes on the coverplate for a finished appearance
(Fig. 7).
6. Apply silicone caulk around the edges of the
coverplate to provide a watertight seal from
rain and moisture.
7. Turn on power at main fuse/breaker box.
4
5
6
7
G
1-1/2 in.
D
F
Round
B
D
1-1/2 in.
Octagonal
Junction box
A
PART 2: ATTACHING FLOOD LIGHT FIXTURE TO ADAPTER PLATE
6. Peel off the adhesive side of the gasket included
with the fixture and place on top of the adapter
plate (A) (Fig. 3).
7. Make all electrical connections using wire nuts
included with the fixture. Refer to fixture instruction
sheet for detailed wiring instructions.
NOTE: Ensure that all ground wires are attached.
8. Line up the holes on the fixture’s coverplate with
the holes on the adapter plate (A). Attach fixture
to the adapter plate (A) using the two #8-32 x 1-¼”
screws included with the fixture (Fig. 4).
9. Insert decorative screw cover caps (included with
the fixture) into the coverplate holes for a finished
appearance.
10. Apply silicone caulk to provide a watertight seal
from rain and moisture.
E
Fig. 3
Fig. 4
TROUBLESHOOTING
Problem Cause / Solution
Light does not
come ON.
G
F
Light flashes Make sure fixture is not on the same circuit as any dimmer,
No power to the fixture.
• Check if circuit breaker tripped.
• Confirm wall switch is ON.
TURN OFF POWER BEFORE CONTINUING
Wiring to the unit is loose.
• Confirm wiring is properly secured.
* If light still does not come on after checking wiring
connections, contact Customer Service.
or ceiling fan
8
A
C
B
WALL AND EAVE SURFACE MOUNT FIXTURE BOXES
PART 1: ATTACHING ADAPTER PLATE TO FIXTURE BOX
For use with 4” round fixture box
1. Determine the proper orientation of the adapter
plate based on your fixture box location. You may
need to drill out the alternate mounting holes to
properly mount the adapter plate to your fixture box
using a 7/32” drill bit.
2. Peel off the adhesive side of gasket (E) and place on
the bottom of the adapter plate (A), making sure to
line up the holes in the gasket with the plate (Fig. 1).
3. Route supply wires through center hole of adapter
plate (A).
4. Place two screws (C) or (D) through two holes
in adapter plate (A) and align with fixture box (not
included). Tighten down both screws (Fig. 2).
5. Apply silicone caulk around the edges of the fixture
box and adapter plate.
E
D
C
Fig. 1
Fig. 2
Junction
box
5-YEAR LIMITED WARRANTY
THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
Cooper Lighting Solutions ("CLS") warrants to customers that, for a period of five years from
the date of purchase, CLS products will be free from defects in materials and workmanship.
The obligation of CLS under this warranty is expressly limited to the provision of replacement
products. This warranty is extended only to the original purchaser of the product. A
purchaser’s receipt or other proof of date of original purchase acceptable to CLS. This is
required before warranty performance shall be rendered. This warranty does not apply to CLS
products that have been altered or repaired that have been subjected to neglect, abuse,
misuse or accident (including shipping damages). This warranty does not apply to products
not manufactured by CLS which have been supplied, installed, and/or used in conjunction with
products. Damage to the product caused by replacement bulbs or corrosion or
CLS
discoloration of brass components are not covered by this warranty.
LIMITATION OF LIABILITY:
IN NO EVENT SHALL CLS BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, STRICT
A
A
LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL THE
LIABILITY OF CLS FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE
TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR
MODIFICATION OF CLS PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE,
EXCEED THE PURCHASE PRICE OF CLS PRODUCTS GIVING RISE TO A CLAIM. NO LABOR
CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES.
To obtain warranty service, please contact CLS, at 1-800-334-6871, press option 2 for
Customer Service, or via e-mail ConsumerProducts@cooperlighting.com and include the
following information:
• Name, address and telephone number
• Date and place of purchase
• Catalog and quantity purchase
• Detailed description of problem
All returned products must be accompanied by a Return Goods Authorization Number issued
by the Company and must be returned freight prepaid. Any product received without a Return
Goods Authorization Number from the Company will be refused. CLS is not responsible for
merchandise damaged in transit. Repaired or replaced products shall be subject to the terms
of this warranty and are inspected when packed. Evident or concealed damage that is made
in transit should be reported at once to the carrier making the delivery and a claim filed with
them.
Reproductions of this document without prior written approval of CLS are strictly prohibited.
or assistance, call 1-800-334-6871 or e-mail us at ConsumerProducts@cooperlighting.com
F
Printed in China
2