WARNING: If the information in these instructions is not followed exactly, a fire
or explosion may result causing property damage, personal injury or loss of life.
—
Do not store or use gasoline or other ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
—
Installation and service must be performed by a qualied installer, service agency
or the gas supplier.
Owner’s Manual
This appliance may be installed in an aftermarket permanently located, manufactured
home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases, unless a certied conversion kit is
used.
Report No. 284-F-06-5
INSTALLER: After installation, explain the operation and maintenance to the owner and leave this manual.
Page 2
TABLE of CONTENTS
TABLE of CONTENTS
IMPORTANT SAFETY INFORMATION .......................................................................3
INSTALLATION RECORD .............................................................................................47
Appendix A - LP Gas Conversion ...........................................................................49
WARNING
CAUTION
Note
These symbols appear throughout this Manual:
This WARNING symbol indicates a situation or condition
which, if not avoided, may result in serious injury or death.
This CAUTION symbol indicates a situation or condition
which, if not avoided, may result in minor injury.
This Note symbol indicates a decision or information point
in the installation process.
Unless otherwise noted, the drawings in this Manual are not to scale.
Halcyon Gas Fireplace EuropeanHome.com
2
Page 3
IMPORTANT SAFETY INFORMATION
1. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 or the Canadian Installation Code, CAN/CGA B149.1.
2. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).
3. The Halcyon Gas Fireplace must be isolated from the gas supply piping system by closing its equipment
shuto valve during any pressure testing of the gas supply system at test pressures equal to or less than
½ psi (3.5 kPa).
4. The installation must provide for adequate ventilation air to the appliance.
5. The Halcyon Gas Fireplace must not be connected to a chimney ue serving a separate solid-fuel
burning appliance.
6. The Halcyon Gas Fireplace, when installed, must be electrically grounded in accordance with local codes,
or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22. 1.
7. When the Halcyon Gas Fireplace is installed directly on carpeting, vinyl tile or other combustible material
other than wood ooring, it must be installed on a metal or wood panel extending the full width and
depth of the appliance. The bottom of the Fireplace complies with this requirement.
8. The area around the Halcyon Gas Fireplace must be kept clear and free from combustible materials,
gasoline and other ammable vapors and liquids.
9. The ow of combustion and ventilation air must not be obstructed.
10. Do not use this Fireplace if any part has been under water. Immediately call a qualied service technician
to inspect the appliance and to replace any part of the control system and any gas control which has
been under water.
11. Due to high temperatures, the Fireplace should be located out of trac and away from furniture and
draperies.
12. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to
avoid burns or clothing ignition.
13. Young children should be carefully supervised when they are in the same room as the appliance.
14. Clothing or other ammable material should not be placed on or near the appliance.
15. Any screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
16. Installation and repair should be done by a qualied service person. The Halcyon Gas Fireplace should be
inspected before use and at least annually by a professional service person. More frequent cleaning may
be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control
compartments, burners and circulating air passageways of the appliance be kept clean.
17. WARNING: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the
glass should be done by a licensed or qualied service person.
Halcyon Gas Fireplace EuropeanHome.com
3
Page 4
MASSACHUSETTS REQUIREMENTS
The following must be observed when installing the Halcyon Gas Fireplace within the Commonwealth of Massachusetts:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or
in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent
termination is less than seven (7) feet above nished grade in the area of the venting, including but not limited to decks and
porches, the following requirements shall be satised:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gastter shall observe that a hard wired carbon monoxide detector with an alarm and
battery back-up is installed on the oor level where the gas equipment is to be installed. In addition, the installing plumber
or gastter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each
additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be
the responsibility of the property owner to secure the services of qualied licensed professionals for the installation of hard wired
carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the
hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent oor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said
thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above
provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certied.
3. SIGNAGE. A metal or plastic identication plate shall be permanently mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating
appliance or equipment. The sign shall read, in print size no less than one-half (½) inch in size, "GAS VENT DIRECTLY BELOW. KEEP
CLEAR OF ALL OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with
the provisions of 248 CMR 5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA
54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the
dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the
equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product
Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the ue gases, but identies
"special venting systems", the following requirements shall be satised by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation
instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a
parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting
instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or
equipment at the completion of the installation.
Halcyon Gas Fireplace EuropeanHome.com
4
Page 5
SPECIFICATIONS
Figure 1 - Dimensions (front)
A
B
C
D
E
ATotal Height44”
BBead-to-Bead Height15⁄”
CGlass Frame Height14⁄”
DViewable Height12¾”
EBead-to-Floor6”
FTotal Width59”
GBead-to-Bead Width51¾”
HGlass Frame Width50½”
IViewable Width48¾”
JCabinet Width (Standos)56¼”
Table 1 - Cabinet Dimensions
I
H
G
F
Figure 2 - Dimensions (rear)
A
Halcyon Gas Fireplace EuropeanHome.com
J
5
Page 6
SPECIFICATIONS
Figure 3 - Dimensions (left side)
Figure 4 - Dimensions (right side)
O
K
Q
N
P
M
L
KHeight Minus Stando33⁄”
LTotal Depth18⁄”
MDepth With Standos18”
NDepth Minus Standos17”
ORear of Cabinet to Center Line of Vent Collar7¼”
PRear of Cabinet to Center Line of Gas Access8⁄”
QBottom of Cabinet to Center Line of Gas Access3⁄”
RCabinet Center Line to Left (or Right) Stando28⁄”
†With Remote Heat Kit installed and maximum horizontal vent run. The maximum obtainable eciency depends on how the
Halcyon Gas Fireplace is installed and operated.
OMNI-Test Laboratories, Inc. has certied that the Halcyon Gas Fireplace meets the ANSI Z21.88-2007 • CSA 2.33-2007 Vented Gas Fireplace Heaters and CAN/CGA-2.17-M91, Gas-Fired Appliances for Use At High Altitudes standards.
†
*
The Halcyon Gas Fireplace is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet)
in Canada without change. If your installation is at an elevation greater than these, consult with the local authority having
jurisdiction for gas product installations to determine their specic requirements for high altitude installations.
The Commonwealth of Massachusetts has approved, and issued approval number G1-0309-294 for, the Halcyon Gas Fireplace.
VENTED GAS FIREPLACE HEATER – NOT FOR USE WITH SOLID FUEL
This vented gas replace heater is not for use with air lters.
This vented gas replace heater is equipped at the factory for use with natural gas. If conversion
to propane (LP) is desired, the optional factory conversion kit must be used.
Natural Gas H50-01-NG
Input BTU/hr.: 32,000
Max. Supply Pressure: 7 inches w.c.
Min. Supply Pressure: 4 inches w.c.
Max. Manifold Pressure: 3.2 inch w.c.
Ori ce Size: #48 DMS
Electrical Rating: 120V AC, 60 Hz, 1.2 A
This product has been tested and listed by OMNI-Test Laboratories to ANSI Z21.88b-2008 •
CSA 2.33b-2008 Vented Gas Fireplace Heaters, CAN/CGA-2.17-M91, Gas-Fired Appliances for
Use At High Altitudes, and CSA P.4.1-02. This appliance equipped only for altitudes 0-2000 feet
(0-610m) in the USA and 0-4500 feet (1370 m) in Canada without change.
This appliance is only for use with the type of gas indicated on the rating plate and may be
installed in an aftermarket, permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. See the Owner’s Manual for details. This appliance
is not convertible for use with other gases, unless a certi ed kit is used.
This appliance must be installed in accordance with local codes, if any; if none, follow the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes,
CSA B149.1 This appliance must be properly connected to a venting system in accordance
with the manufacturer’s installation instructions.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a quali ed installer, service agency or
the gas supplier.
SEVERE BURNS MAY RESULT. KEEP CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE
VAPORS AWAY.
CAUTION:Do not operate the appliance with glass
removed, cracked or broken. Replacement of the panel should
be done by a licensed or quali ed service person.
Minimum Clearances to Combustible Materials
Side, Top and Rear Stando s: 0” (0mm)
Floor Under Unit: 0” (0mm)
Top of Enclosure: 23.25” (591mm)
Door to Right Side Wall: 7” (178mm)
Door to Left Side Wall: 7” (178mm)
Thank you for purchasing the Halcyon Gas Fireplace by European Home.
Please read this manual thoroughly before beginning the installation of your Halcyon Gas Fireplace. It has information which is
important for safe, trouble-free installation and operation.
Your Halcyon Gas Fireplace will arrive in two packages; the cabinet - including the burner and glass panel assembly - on a pallet,
and a carton with everything else. Please inspect your shipment for completeness and any damage. Contact your retailer if any
damage is found. Do not install your Halcyon Gas Fireplace with any damaged or substituted parts.
The installation of your new Fireplace will follow the steps below and this Manual is laid out accordingly.
P. Planning - Fireplace and venting location, gas and electric supply runs and clearances
1. Rough Installation - Build the rough frame and install the Fireplace
2. Electric Installation - The electric supply connections and the control switches
3. Gas Installation - The gas hook-up
4. Venting Installation - 8” direct vent pipe, adjustment and termination
5. First Fire - Check for proper operation and burn-in
6. Fine Tuning - Electrical check, gas check and pressure tests, draft adjustment
7. Final Installation - Wall, mantel and non-combustible facing
Before you begin your installation you should have the
following tools and supplies:
• Saw
• Hammer
• Pliers
• Pipe wrench
• Phillips and straight-blade screwdrivers
• Plumb line and level
• Tape measure and framing square
• Electric drill and assortment of drill bits
• Safety glasses and gloves
• Framing material
• Non-combustible nish material
• Approved pipe joint sealant
• Manometer
• #6 or #8 self-tapping screws, ½” ¾” long
• Leak detection uid (non-corrosive) or electronic gas
detector
• 14/2 NM electrical wire and wire nuts
• Two 15A 120V single pole toggle switches
• Appropriate venting components
• Appropriate gas supply line parts
Halcyon Gas Fireplace EuropeanHome.com
9
Page 10
PRE-INSTALLATION PLANNING
The next eight pages provide information for the Planning portion of your project.
P1. LOCATING THE FIREPLACE
Several issues must be addressed when selecting a suitable location for the Halcyon Gas Fireplace. Considerations include
observing the required clearances to combustible materials, the accessibility of the gas and electric supply and the routing of the
gas vent.
A number of installation styles are possible; a corner, an island, a peninsula, built into a wall or enclosed by walls.
For maximum performance, you should choose a Fireplace location which minimizes the number of bends and horizontal lengths
in the venting run. Figure 6 shows some example installations.
Since the Halcyon Gas Fireplace weighs several hundred pounds, it must be placed on a sturdy and level surface. It can be placed
on the oor or a raised platform made of wood or non-combustible materials - do not place the Fireplace on carpet or vinyl tile.
7”
93”
minimum
7”
minimum
7”
minimum
Figure 6 - Installation Locations (not to scale)
Halcyon Gas Fireplace EuropeanHome.com
10
Page 11
PRE-INSTALLATION PLANNING
T
U
Figure 7 - Rough Opening
Table 3, below, lists the minimum dimensions of the rough opening
(shown in Figure 7) into which the Halcyon Gas Fireplace is set. It also
lists the minimum height of an enclosure (W) and the minimum distance
between a room ceiling and the bottom of the Halcyon (V).
Figure 8 shows the relationship between a room ceiling (V) and an
enclosure (or chase) ceiling (W).
SRough Opening Width57”
TRough Opening Height44”
URough Opening Depth18½”
VMinimum Height to Chase Ceiling57½”
WMinimum Height to Room Ceiling44”
Table 3 - Minimum Dimensions
S
V
W
Figure 8 - Minimum Enclosure Height and Distance to Ceiling
Halcyon Gas Fireplace EuropeanHome.com
11
Page 12
PRE-INSTALLATION PLANNING
P2. ABOVE THE FIREPLACE
Almost all of the heat produced by the Halcyon Gas Fireplace rises directly up the wall into which it is set. This subjects the wall
above the Fireplace (and anything attached to the wall) to elevated temperatures. The European Home Remote Heat Kit (included)
is designed to keep the wall cooler by moving heat away from the Fireplace. Your Fireplace is supplied with enough insulated,
exible duct to allow the Remote Heat Kit to be installed in a simple, ‘bump-in’ enclosure. If your installation requires more duct it
is available through your retailer or from European Home. NOTE: A grille for each duct box is NOT included and must be provided
by the customer. The grille MUST have a minimum open area of 41%.
Figure 9 and Table 4 show some typical wall surface temperatures at various distances from the Facing Bead on the Halcyon Gas
Fireplace. These temperatures are shown with no mantel attached. The inclusion of a mantel will have no material aect on the
wall temperatures above the Fireplace.
This information is intended to better inform your decision to attach objects above the Fireplace. European Home cannot predict
the eects of heat on anything attached above the Fireplace and the nal choice of objects, attachments and materials rests
entirely with the customer. European Home takes no responsibility for any eects, good or bad, of heat upon any objects attached
above the Fireplace.
100° F (37.7° C) with no open ducts
90° F (32.2° C) with two open ducts
100° F (37.7° C) with two open ducts
Facing Bead (Top)
D
3
D
2
D
1
Figure 9 - Surface Temperature Prole (not to scale)
The rst vent section must be a 12”, or longer, vertical section. Try to minimize the length of horizontal sections and the number of
elbows. Your proposed vent conguration should oer as little resistance as possible to the rising of hot air.
Any venting conguration used by the Halcyon must fall within the limits of Chart 1. All measurements are taken from the center
of the vent connector on the top of the Halcyon cabinet. See Figure 10.
To use the Chart 1, measure the total rise and total run of your proposed venting conguration. On the chart, draw a line between
the two numbers (top and bottom rows of the chart) representing your run and the two numbers (left and right columns of the
chart) representing your rise. Mark the point at which the lines intersect. If that point falls in a black area the conguration is not
permitted. Installations whose rise or run falls outside the chart are not permitted.
For example, if your vent rise is 18 feet and your vent run is 12 feet the venting is not permitted. Conversely, if your vent rises 7 feet
and your vent run is 11 feet the venting is permitted.
Halcyon Gas Fireplace EuropeanHome.com
Total Vertical Rise (Feet)
Total Horizontal Run (Feet)
= Conguration is
ALLOWED
= Conguration is
Chart 1 - Allowable Venting Chart
rise
run
Figure 10 - Vent Measurement
PROHIBITED
13
Page 14
v
FIXED
CLOSED
OPERABLE
OPERABLE
FIXED
CLOSED
v
v
v
v
v
v
J
B
B
B
A
A
B
B
E
D
A
K
B
F
C
L
Termination Not Permitted
A
Air Supply Inlet
v
Venting Termination
H
I
PRE-INSTALLATION PLANNING
Note
Vent terminals shall not be
recessed into a wall or siding.
Figure 11 - Terminal Clearances
ClearanceU.S. Minimum
1
Canadian Minimum
A - Clearance above the grade, a veranda, porch, deck, or balcony.12 in. (30 cm)12 in. (30 cm)
B - Clearance to window or door that may be opened.12 in. (30 cm)12 in. (30 cm)
C - Clearance to permanently closed window.See Note 3See Notes 3 and 4
D - Vertical clearance to ventilated sot located above the terminal
See Note 3See Notes 3 and 4
within a horizontal distance of 2 ft. (61 cm) from the center line of
the terminal.
E - Clearance to an unventilated sot.See Note 3See Notes 3 and 4
F - Clearance to an outside corner.See Note 3See Notes 3 and 4
G - Clearance to an inside corner.See Note 3See Notes 3 and 4
H - Clearance to each side of centerline of gas meter/regulator assembly.
See Note 33 ft. (91 cm) within a height
of 15 ft. (4.5 m) above the
meter/regulator assembly
I - Clearance to a service regulator vent outlet.See Note 33 ft. (91 cm)
J - Clearance to non-mechanical air supply inlet into building or the
9 in. (23 cm)12 in. (30 cm.)
combustion air inlet to any other appliance.
K - Clearance to mechanical air supply inlet.3 ft. (91 cm) above if within
10 ft. (3 m) horizontally
L - Clearance above a paved sidewalk or paved driveway located on
public property.
M - Clearance under veranda, porch, deck or balcony.See Note 312 in. (30 cm)
Notes:
1 - In conformance with the current National Fuel Gas Code, ANSI Z223.1
2 - In conformance with the current CAN/CGA B149 Gas Installation Code
3 - Clearance is accordance with local installation codes and the requirements of the gas supplier
4 - Degagement conforme aux codes d’installation locaux et aux exigences du fournisseur de gaz.
See Note 37 ft. (2.12 m)
6 ft. (1.83 m)
See Note 5
Table 5 - Minimum Terminal Clearances
5 - Permitted ONLY if veranda, porch, deck or balcony is fully open on a minimum of two sides below the oor.
2
Halcyon Gas Fireplace EuropeanHome.com
14
Page 15
MINIMUM CLEARANCES to COMBUSTIBLES
P4. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
When installing the Halcyon Gas Fireplace, the clearances shown in Table 6, below, must be observed. If the required clearances
are not maintained a re may result thereby causing property damage, personal injury or loss of life.
When the Halcyon Gas Fireplace is to be installed directly on carpeting, vinyl tile or combustible material other than wood ooring, it must be installed on a metal or wood panel extending the full width and depth of the Fireplace cabinet.
Clearance to Side, Top and Rear Standos
Clearance to Wood Floor
Clearance to Side Wall
Distance Between Cabinet Bottom and Enclosure Ceiling
Clearance to Vent Pipe (Horizontal or Vertical)
What is Combustible?
Materials that can catch re and burn are considered combustible.
Any material that is made of, or faced with, wood, wood pulp,
paper, plastic or any other material that can catch re and burn is
considered combustible. Even though these materials may have
been 'ame-proofed', made 're-resistant' or are 're-rated' they
are considered combustible.
The combustibility of a material can be tested per "ASTM E136
Standard Test Method for Behavior of Materials in a Vertical Tube
Furnace at 750 Degrees C". Note that 're-resistant' does NOT
mean non-combustible.
Note: If a certain material has a core considered to be noncombustible (in accordance with ASTM E136) but is faced with
a combustible material then the material is considered to be
combustible.
When in doubt, ask for an ASTM E136 compliance statement.
0”
0”
7”
57½”
1½“
Table 6 - Minimum Clearances to Combustible Materials
What is Non-combustible?
A given material is said to be non-combustible when it cannot
catch re and burn. For example, materials made entirely, or in
combinations, of, stone, brick, concrete, tile, steel, plaster or glass
are considered non-combustible.
For the purposes of the installations described in this Manual,
those materials that have passed the ASTM E136 tests are
considered to be non-combustible.
As of this writing, the materials listed below are reported by
their manufacturers to be non-combustible (in accordance with
ASTM E136):
• James Hardie Building Products, Inc.:
HardieBacker™ ¼” Cement Board
All of the following limits MUST be maintained in every case:
• Combustible mantels must be no closer to the top of the glass panel frame than the distances shown in Figure 12.
• Combustible materials must be no closer to the side of the glass panel frame than 7”.
• The bottom of the Halcyon cabinet may be no closer to the room ceiling than 44”.
• The minimum height of an enclosure is 57½”.
• Figure 13 shows the combustible facing limits for the Halcyon Gas Fireplace. Combustible wall facing is not permitted inside
this 65¾” x 44” limit. The 44” dimension is measured from the bottom of the cabinet to the top of the stando panel and the
65¾” dimension is centered on the cabinet.
• The wall must be faced with non-combustible material, usually approved cement board. See What is Non-combustible? on
page 15.
Halcyon Gas Fireplace EuropeanHome.com
17
Page 18
INSTALLATION
Relief
Opening
Slotted
Retainer
Line-up
Tab
The Rough Installation portion of your project includes placing the cabinet, connecting the gas and making the electrical connections.
The following steps provide the detail.
1. REMOVE THE GLASS PANEL ASSEMBLY
The glass panel is fastened to the cabinet at the factory and should be removed and placed in a safe location to avoid damage.
See Section 8 (INSTALL THE GLASS PANEL ASSEMBLY) for details. Due to the size and weight of the glass panel assembly, the
assistance of a helper is recommended.
Note
TO USE LP GAS, CONVERT THE HALCYON GAS FIREPLACE NOW USING ONLY THE H50-SA-LPCK-01 LP GAS CONVERSION KIT.
The H50-SA-LPCK-01 LP Gas Conversion Kit is sold separately. See Appendix A for complete conversion instructions.
Note
Check the VENTING section now to determine if your installation requires the Horizontal Heat Shield. If required, install it now.
2. INSTALL THE RELIEF DOORS
a. When shipped, four relief doors are not installed and must be installed on the top of the rebox prior to installation. These four
relief doors include gasket material that covers the full bottom surface. Use care in handling the relief doors to avoid damage
to the gasket material.
b. The relief openings are located behind the left and right access doors mounted on the front of the Halcyon Gas Fireplace.
Using the nger hole, slide the door left or right the door as appropriate.
Figure 14 - Relief Openings and Slotted Retainers
Halcyon Gas Fireplace EuropeanHome.com
Figure 15 - Relief Door Showing Line-up Tab
18
Page 19
INSTALLATION
Figure 16 - Relief Door Showing Line-up Tab
c. The four relief doors include line-up tabs that correspond to slotted retainers on the rebox. See Figure 14.
d. Drop the rear of each relief door down onto its slotted retainer and allow the rear line-up tab to engage the rear retainer slot.
See Figure 15.
e. Lift the front edge of each relief door and engage the line-up tab in the front slotted retainers.
f. The four relief doors must be able to move up and down freely on the retainers when properly installed.
g. When the relief door installation is complete, the relief doors should be in the full down position. See Figure 16.
3. PLACE THE CABINET
Since the Halcyon Gas Fireplace weighs several hundred pounds, it must be placed on a sturdy and level surface. It can be placed
on the oor or a raised platform made of wood or non-combustible materials - do not place the Fireplace on carpet or vinyl tile.
a) Place the Halcyon Gas Fireplace into the rough opening. Framing material can touch the standos at the sides and rear of the
cabinet but do not place anything between the framing and the standos.
b) Make sure the Fireplace is both level and square.
c) Screw the left and right attachment anges to the framing.
Note
Do not enclose the Fireplace chase or begin the nish work until the Fireplace has been installed, tested and approved by the
local code inspection authority.
Halcyon Gas Fireplace EuropeanHome.com
19
Page 20
INSTALLATION - ELECTRICAL ASSEMBLY
WARNING
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
This appliance must be electrically grounded in accordance with local codes, or, in the absence of local codes, with either the
National Electrical Code ANSI/NFPA 70, for installations in the U.S. or the Canadian Electrical Code, CSA C22. 1 for installations in
Canada.
Electrical work should only be performed by a qualied, licensed electrician. Electric power must be o when making
connections at the Junction Box or performing any service.
All wiring shall be in compliance with all local, city, and state codes.
4. THE ELECTRICAL ASSEMBLY
The three electrical circuits required by your project are detailed in this section.
The Halcyon Gas Fireplace requires seven electrical connections for complete operation; a system ground (earth) connection
plus two connections to the Lamp Circuit, two connections to the Control Circuit and two connections to a thermostat or remote
control receiver. The Control and Lamp Circuits are provided on-site and must be installed according to all applicable codes; the
Thermostat Wire is provided with the Halcyon.
When completed, all of these connections are inside the Wiring Tunnel, located behind the Cover Plate on the lower left side of the
Halcyon. Figure 18 shows a schematic electrical wiring diagram and Table 7 lists the wire colors.
Lamp Circuit
A switched 120V AC circuit must be installed in order to light the two interior lamps. The switch may be either a lamp dimmer
rated for at least 500 watts (recommended) or a SPST switch. The Lamp Circuit is connected to the blue and purple wires.
Control Circuit
The Control Circuit is a 120V AC supply circuit which provides electrical power solely to the Control Module and is used to power
the control and safety systems. The Control Circuit must not contain a dimmer but it may be switched. The Control Circuit is
connected to the black and white wires.
Thermostat Circuit
The Thermostat Circuit is powered by a 24V AC transformer inside of the Halcyon and consists of 25 feet of thermostat wire (wired
to the Control Module) and a remote control receiver (included.) Alternatively, the Thermostat Circuit may be wired to a customerprovided 24V thermostat or SPST switch.
DO NOT CONNECT AN EXTERNAL POWER SOURCE TO THE THERMOSTAT CIRCUIT!
Halcyon Gas Fireplace EuropeanHome.com
Note
20
Page 21
INSTALLATION - ELECTRICAL ASSEMBLY
Lamp
Circuit
Control
Circuit
Thermostat
Circuit
Figure 17 - Wiring Tunnel Cover Plate
Figure 17 shows the Wiring Tunnel Cover Plate with circuit wires installed.
To make the required electrical connections:
a) Remove the two screws holding the Cover Plate in place.
b) Pass the Lamp Circuit wire through the left hand wire clamp and the Control Circuit wire through the right hand wire clamp.
c) Tighten the wire clamps while leaving at least ten inches of Lamp Circuit and Control Circuit slack inside the Wiring Tunnel. This
slack will allow the connections to be in compliance with the National Electrical Code.
d) Using wire nuts, connect the Lamp Circuit to the blue and purple wires and connect the Control Circuit to the white and black
wires.
e) Connect the green ground wire to an appropriate ground in accordance with local codes, or, in the absence of local codes,
with either the National Electrical Code ANSI/NFPA 70, for installations in the U.S. or the Canadian Electrical Code, CSA C22. 1
for installations in Canada.
f) While ensuring that at least ten inches of slack remains within the Wiring Tunnel, run the thermostat wire to the work box and
connect it to the receiver.
g) With the connections secure, push all slack inside the Wiring Tunnel and attach the Cover Plate.
Halcyon Gas Fireplace EuropeanHome.com
21
Page 22
INSTALLATION - ELECTRICAL ASSEMBLY
CONTROL
MODULE
GAS
VALVE
REMOTE
CONTROL
RECEIVER
MV (+)
MV (-)
PV (-)
PV (+)
MV
VAL
PV
TH
L1
to 1 x 120 V AC
SWITCHED CONTROL
Control SchematicLamp Schematic
TR
N
CIRCUIT
FLAME
SPARK
GND
TRANSFORMER
G
FLAME
SENSOR
SPARK
IGNITOR
LAMPS
L1
to 1 x 120 V AC
SWITCHED LAMP
CIRCUIT
N
G
NameColorVoltage
Receiver
(Remote Control)
Transformer Power
Lamp Power
WHITE
RED24V AC
BLACK110V AC
WHITE
BLUE110V AC
PURPLE
Device GroundGREEN—
Table 7 - Wire Colors for External Connections
Figure 18 - Lamp and Control Electrical Schematic Diagrams
24V AC
110V AC
110V AC
Halcyon Gas Fireplace EuropeanHome.com
22
Page 23
INSTALLATION - GAS SUPPLY
5. INSTALL THE GAS SUPPLY
Section 5 details the Gas Installation portion of your project.
Note
This product must be installed by a licensed plumber or gastter when installed
within the Commonwealth of Massachusetts.
The installation of the Halcyon Gas Fireplace must conform with local codes or, in
the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 in the U.S. or
the Canadian Installation Code, CAN/CGA B149.1 in Canada.
The Halcyon Gas Fireplace is shipped from the factory for use with natural gas. If LP
gas is to be used the Halcyon Gas Fireplace must be converted using the H50-SALPCK-01 LP Conversion Kit only. Refer to the instructions included in the Conversion
Kit.
Route the gas supply into the right side of the Fireplace cabinet (see Figure 19). The
gas supply piping should have a separate gas shuto valve and a capped, ⁄” pipe
tapping upstream of the valve for the purpose of reading pressure. A service shuto
valve must be placed within six feet of the Halcyon gas control valve.
Opening for Burner Connection
Figure 19 - Right Side of Cabinet Showing Gas
Supply Opening
The gas supply line must terminate with a ⁄” male are tting.
The Halcyon Gas Fireplace and its main control valve must be disconnected from
the gas supply system during any pressure testing of that system at test pressures
in excess of ½ psi (3.5 kPa). The Halcyon Gas Fireplace must be isolated from the gas
supply system by closing the service valve during any pressure testing of the gas
supply system at test pressures equal to or less than ½ psi (3.5 kPa).
Verify the gas pressure using the upstream ⁄” pipe tap.
Halcyon Gas Fireplace EuropeanHome.com
23
Page 24
INSTALLATION
1235678910
4
6. INSTALL THE INTERIOR PANELS
a) While wearing gloves, remove any protective lm from each of the ten interior panels. Handle the panels with care so as to
leave as few marks as possible. This will make cleaning them easier.
b) Set the left and right side panels (1, 2) into place in the order shown in Figure 20. Fasten panels 1 and 2 with their top clips.
c) Set the four rear panels (3, 4, 5, 6) into place as shown in Figure 20. Fasten panels 3 and 4 and panels 5 and 6 with the top clips.
Ensure that there are no gaps between the panels and that they are centered.
d) Set the four bottom panels (7, 8, 9, 10) into place in the order shown in Figure 20.
e) Clean all of the panels completely before the First Fire. If the panels are not completely clean the heat can cause permanent
stains. See the MAINTENANCE section.
Figure 20 shows Stainless Steel panels; other panel types are also available.
Figure 20 - Halcyon Panel Numbers
7. INSTALL THE MEDIA
The contents of the bag of Burner Media should be spread to an even depth over the entire burner top.
a) Cut one corner of the bag to form a pouring spout through which the ow of Media can be controlled.
b) Begin at the left end pour the Media onto the center of the burner tray while moving to your right. Care should be taken to
avoid spilling the Media into the bottom of the cabinet. Note that if some spillage does occur there will be no harm but less
Media.
c) After the bag has been emptied on the burner carefully smooth the Media to a uniform depth on the tray. Be certain that glass
does not come within ¼” of the pilot burner hood. Both parts of the pilot ame must be present as in Figure 21.
d) If you have ordered other Media, such as Stones, lay it on and around the burner taking care to avoid covering more than 10
percent of the opening between the burner top and the hearth panels.
Halcyon Gas Fireplace EuropeanHome.com
24
Page 25
INSTALLATION
CAUTION
Do not operate this appliance with the glass panel removed, cracked or broken. Replacement of the glass panel should be done
by a licensed or qualied service person.
8. INSTALL THE GLASS PANEL ASSEMBLY
Proper care of the glass panel assembly is important for the safe operation of the Halcyon Gas Fireplace. Do not abuse the glass
panel assembly by slamming , striking or scratching it.
When replacing the glass panel assembly use only European Home part number H50-SA-GP-01, substitute parts are not permitted.
Replacement part numbers are listed in the MAINTENANCE section. Replacement of the glass panel assembly should be done by
a qualied service person. Due to the size and weight of the glass panel assembly, caution should be exercised when removing or
installing it.
Removing and installing the glass panel assembly requires it to be held as vertically as possible. Take care to not scratch the nish
on the glass panel frame as it is moved in and out. See Figure 22.
Figure 21 - Correct Pilot Burner Flame Pattern
Halcyon Gas Fireplace EuropeanHome.com
Figure 22 - The Vertical Installation of the Glass Panel Assembly
25
Page 26
INSTALLATION
In order to ease the latching/unlatching of the glass panel assembly, the Halcyon Gas Fireplace comes equipped with a standard
⁄” combination wrench. The wrench is used to make it easier to move the latches – your ngers can do the job just as well.
The tab on the handle of the latches is sized to accept the “box”, or closed, end of the wrench. Holding the wrench at about a 45°
angle to the latch, slip the box end of the wrench over the tab of the latch thus creating an extension of the latch. See Figure 23.
To remove the glass panel assembly, refer to Figure 23 and:
a) Unfasten Latch 2 and Latch 3 by swinging Latch 2 clockwise and Latch 3 counter-clockwise until they swing free of their
catches.
b) Unfasten Latch 1 and Latch 4 by swinging Latch 1 clockwise and Latch 4 counter-clockwise until they swing free of their
catches.
c) Using two hands, swing the bottom edge of the panel out and lift the top of the panel o its mounting rail while moving the
glass panel toward yourself.
To install the glass panel assembly, refer to Figure 23 and:
a) Tilt the top of the glass panel in towards the Fireplace and hang the top lip on its mounting rail on the Fireplace ensuring that
the glass is centered on the face and the gasket does not get pinched at the top of the frame.
b) Fasten Latch 2 and Latch 3 by swinging Latch 2 counter-clockwise and Latch 3 clockwise until they engage their catches.
Fasten the two latches at the same time to ensure that the panel remains centered.
c) Fasten Latch 1 and Latch 4 by swinging Latch 1 counter-clockwise and Latch 4 clockwise until they engage their catches.
1432
Open
Figure 23 - Four Latches Holding the Glass Panel Assembly (shown from above)
Halcyon Gas Fireplace EuropeanHome.com
OpenOpen
26
Open
Page 27
INSTALLATION - VENTING
9. CONFIGURING THE VENTING
This section provides venting information which is specic to the Halcyon Gas Fireplace.
The Halcyon Gas Fireplace is a direct vent replace that uses a co-axial or “pipe within a pipe” venting system. The outer “pipe”
or vent (8” diameter) conducts outside air into the Fireplace and the inner vent (5” diameter) carries the exhaust outside. This
technology, which can run either horizontally through a side wall or vertically through the roof, produces an ecient system
because conditioned building air is not used for combustion.
All of the following bulleted points apply to every installation:
• The Halcyon Gas Fireplace requires 5”/8” direct vent components from any of the manufacturers listed in Table 8. Approved
terminations are also listed in Table 8.
• All measurements are taken from the center of the vent connector on the top of the Halcyon cabinet (see Figure 24) and all
congurations must fall within the acceptable range of Chart 1.
• The maximum allowable rise is forty feet and the maximum allowable run is fteen feet but not in combination; see Chart 1.
• The minimum vent conguration is a 12” vertical rise to a 90° elbow plus a 6” horizontal run to a sidewall termination. This
means that the rst vent section must be a 12”, or longer, vertical section.
40’
max.
rise
APPROVED TERMINATIONS by MANUFACTURER
ManufacturerHorizontalVerticalSnorkel
American Metal Products Group5DHCS, 5DHC5DVC—
Selkirk Corp.5DT-HC5DT-VC, 5DT-VT5DT-ST14
Simpson Manufacturing, Inc.58DVA-HC58DVA-VC—
Table 8 - Approved Terminations by Manufacturer
15’
max.
run
Figure 24- Maximum Venting
Halcyon Gas Fireplace EuropeanHome.com
27
Page 28
INSTALLATION - VENTING
• When installed with one foot of rise, the Halcyon can be installed with no more than two 90° elbows OR four 45° elbows OR a
combination totaling no more than 180° ‘elbow degrees’. For example, a combination of one 90° elbow and two 45° elbows is
allowed (90° + 45° + 45° equals 180°) but a combination of two 90° elbows and two 45° elbows is not allowed (the total equals
270°.)
• When installed with more than one foot of rise, the Halcyon can be installed with no more than three 90° elbows OR six 45°
elbows OR a combination totaling no more than 270° ‘elbow degrees’. For example, a combination of two 90° elbows and two
45° elbows is allowed (90° + 90° + 45° equals 270°) but a combination of two 90° elbows and three 45° elbows is not allowed
(the total equals 315°.) These elbows can be installed either horizontally or vertically.
•The rst 90° elbow must have the Horizontal Heat Shield either mounted to the top of the elbow with the enclosed Heat
Shield Mounting Bracket or mounted on the wall as shown in Figure 25.
• A minimum clearance of 1½” must be maintained between combustible materials and any horizontal or vertical vent pipe
surface.
• The horizontal parts of the venting must be pitched up, away from the Fireplace. For every 12 inches of horizontal run, the
venting must rise ¼” toward the termination. The venting must never run downward.
• Whenever venting passes through a wall, a heat shield, or ‘wall thimble’, from any of the manufacturers listed in Table 8 must
be installed.
Horizontal
Heat Shield
Halcyon Gas Fireplace EuropeanHome.com
Figure 25 - Horizontal Heat Shield
28
Page 29
INSTALLATION - VENTING
10. ADJUSTING THE DRAFT
As the Halcyon Gas Fireplace warms the attached venting, a draft is created. This draft acts on both the intake and exhaust sides
of the venting and produces an eect on the Fireplace ames. In order to obtain the performance for which the Halcyon was
designed, the air intake and exhaust outlet must be adjusted before the installation is complete.
These adjustments are made by setting an Adjustment Quadrant according to Chart 2 (when burning natural gas) or Chart 3 (when
burning LP gas.) On each Chart the air intake setting is designated by a letter from A through E and the exhaust outlet setting is
designated by a number from 0 through 4.
Because the Quadrants are accessible only through the right hand opening in the cabinet face (shown in Figure 26), the wall must
remain open until the Fireplace has been tested and is operating properly.
Setting the Restrictors
Air Intake
Adjustment
Quadrant
Exhaust Outlet
Adjustment
Quadrant
The Restrictor Settings Charts (pages 32-33) accommodate
venting congurations with up to forty feet of rise and fteen
feet of run but not both.
a) Measure the total amount of vertical rise and the total
amount of horizontal run in your conguration. (The
example in Figure 26 has 8 feet of rise and 9 feet (3’ + 6’ =
9’) of run.)
Figure 26 - Restrictor Adjustment Quadrants
b) Using the appropriate Chart (Natural or LP gas), nd the
number equal to your rise in the lefthand column and the
number equal to your run in the bottom row.
c) The intersection of your rise and run will be in a distinct
section of the Chart labeled with a double box like this:
If the intersection square is black the vent conguration is
NOT allowed. The lefthand half of the box shows the
setting for the Air Intake Adjustment Quadrant and the
righthand half shows the setting for the Exhaust Outlet
Adjustment Quadrant.
Halcyon Gas Fireplace EuropeanHome.com
29
Page 30
INSTALLATION - VENTING
d) Loosen the wingnut holding the Air Intake Adjustment Quadrant and turn the Quadrant to align the index mark with the
appropriate setting on the Quadrant. Tighten the wingnut so that Quadrant can’t move.
e) Loosen the wingnut holding the Exhaust Outlet Adjustment Quadrant and turn the Quadrant to align the index mark with the
appropriate setting on the Quadrant. Tighten the wingnut so that Quadrant can’t move.
Example A
Using the vent conguration shown in Figure 27, and assuming LP gas fuel, we see that the intersection of 8 feet (total rise) and 9
feet (total run) falls within the section labeled:
This means that the Air Intake Adjustment Quadrant is set to a position one half of the way between B and C and the Exhaust Outlet Adjustment Quadrant is set to a position one half of the way between 2 and 3.
Example B
With the same Figure 27 example but assuming natural gas fuel, the intersection of an 8 foot rise and a 9 foot run falls within the
section labeled:
In this case, the Air Intake Adjustment Quadrant is set to a position one half of the way between C and D and the Exhaust Outlet
Adjustment Quadrant is set to a position one quarter of the way between 3 and 4.
C½ 3¼
B½ 2½
8’
6’
3’
Figure 27- Venting Example
Halcyon Gas Fireplace EuropeanHome.com
30
Page 31
16’
INSTALLATION - VENTING
12’
Figure 28- Venting Example
Example C
Using the dimensions shown in Figure 28, the intersection of the rise (16’) and run (12’) on either
Chart is black. Therefore, this conguration is not allowed.
10’
3’
6’
Figure 29- Venting Example
Example D
The example shown in Figure 29, (10’ of rise and 9’ of run) has four
90° elbows and is, therefore, not allowed.
Halcyon Gas Fireplace EuropeanHome.com
31
Page 32
INSTALLATION - VENTING
Chart 2 - Air Intake and Exhaust Outlet Restrictor Settings - NATURAL GAS
The Halcyon Remote Heat Kit provides a method by which heat is moved away from the Halcyon Gas Fireplace. This serves
two purposes; to lower the temperature of the wall face above the Halcyon and to provide heat to another part of the room or
building.
The Remote Heat Kit consists of the following pieces:
• Flexible Insulated Duct
• (2) 10” x 12” Duct Boxes
• (2) Duct Collars
NOTE: A grille for each duct box is NOT included and must be provided by the customer. The grille MUST have a minimum open
area of 41%.
PLANNING
The Remote Heat Kit operates passively; it has no fan. This means that your installation must allow for the unobstructed, free ow
of warm air from the Halcyon Gas Fireplace, through the duct and out of the duct boxes. This can be accomplished by ensuring
that:
a. the duct always rises and
b. the duct is never blocked and
c. the duct boxes are at the high point (and the Halcyon is at the low point) of the Heat Kit installation.
For best performance, i.e. the lowest wall temperature and most warm air, both Remote Heat ports on the Halcyon Gas Fireplace
must be opened and have ducts properly attached. If only one port is ducted the resulting wall temperature will be higher than if
two ports are ducted.
The Remote Heat Kit components can accommodate several dierent installation congurations but the following applies to
every installation:
• When installed, the center of the Remote Heat Kit duct box must be at least 12 inches above the top of the cabinet and
should be in line with the center of the cabinet.
• The insulated duct can be no longer than 10 feet.
• At least 30% of the total length of the insulated duct must run vertically.
• When choosing the duct box nish, do not use a register instead of a grille. If the ow of warm air from the Halcyon Gas
Fireplace is blocked the wall above the Glass Panel Assembly will be subjected to elevated temperatures. The grille MUST
have a minimum open area of 41%.
• The insulated duct must not terminate in a oor-mounted grille; only wall-mounted grilles are permitted.
• The top of the duct box must be at least one inch below any ceiling or mantel. See Figure 30.
• All ducts must be xed so as to remain at least 1½” away from any vertical venting component and 6” away from any
horizontal venting component.
• The ducts must always terminate within the building envelope AND the ducts MUST terminate in an area which allows the
free ow of cool air back to the replace front. Do not terminate the ducts in an enclosed room or space.
Halcyon Gas Fireplace EuropeanHome.com
34
Page 35
INSTALLATION - REMOTE HEAT KIT
Ceiling Line
A
B
C
AMinimum Distance to Ceiling1”
B Minimum Height Above Cabinet Top 12”
C Distance Between Framing Members 14”
Table 9 - Clearances and Dimensions
Figure 30 - Remote Heat Kit Clearances
INSTALLATION (Two Ducts)
a) Remove the screws holding the left and right upper cover. Remove both covers. See Figure 32.
b) Remove the insulation discs and lower covers.
c) Leave the two gaskets in place on the cabinet top.
d) Place two duct collars on the cabinet top, one around each of the ports and align them with the existing screw holes.
e) Screw each duct collar to the cabinet.
f) Mount the left and right duct boxes within their respective rough openings. See Figure 31.
g) Cut the insulated duct into the appropriate lengths from that supplied in the kit.
Halcyon Gas Fireplace EuropeanHome.com
35
Page 36
INSTALLATION - REMOTE HEAT KIT
h) Push the poly sheath and insulation back to expose the
metal core. It is easier to pull the metal core onto both
the duct box and duct collar than to push it.
i) Working with one hand inside and one hand outside,
slowly work the metal core onto both the duct box and
duct collar.
Figure 31 - Duct Box
Rough Opening Dimensions
14”
Upper Cover
Insulation Disc
Lower Cover
Port
12”
j) Secure each end with two sheet metal screws.
Figure 32 - Exploded View of the Halcyon
Remote Heat Port.
Halcyon Gas Fireplace EuropeanHome.com
36
Page 37
INSTALLATION - REMOTE HEAT KIT
OPERATION
As the Halcyon Gas Fireplace heats the air within the cabinet it rises up through the insulated ducts and out through the grilles.
This heated air is replaced with cooler room air that enters the cabinet from around the Glass Panel Assembly. When the Halcyon
cools, the movement of air stops.
NOTE: Make sure that the Heat Kit can move air away from the replace; otherwise the wall face above the replace will be
subjected to elevated temperatures. Refer to Section P2 (PRE-INSTALLATION PLANNING) for more information.
REPLACEMENT PARTS
If replacement parts are required, only parts made specically for your Halcyon Gas Fireplace can be used. Failure to use only parts
specically approved with this appliance may result in property damage or personal injury. Table 9 lists parts approved for use in
the Halcyon Gas Fireplace.
Part NumberDescription
H50-SA-INDP-01 Insulated Duct
H50-SA-DB-01Duct Boxes and Collars
Table 9 - Replacement Parts List
Halcyon Gas Fireplace EuropeanHome.com
37
Page 38
OPERATING the FIREPLACE
12. BEFORE THE FIRST FIRE
1. Make sure all construction materials have been removed from inside and around the Fireplace.
2. Conrm the proper placement of the interior panels.
3. Conrm the proper placement of the burner media.
4. Conrm that the electrical wiring is properly connected.
5. Check the gas supply for leaks.
6. Close and properly latch the glass panel.
7. Check that the venting is unobstructed and in proper working condition.
13. THE FIRST FIRE
How to light your Halcyon Gas Fireplace for the rst time is detailed in this section.
The rst time you light your Halcyon Gas Fireplace an odor may be given o by the unit. This is normal and is a result of the ‘burn
o’ of the lubricants and sealants used when manufacturing the Fireplace. We recommend that you open the nearby windows for
extra ventilation and operate the Fireplace for at least four hours.
Upon lighting the Fireplace when the glass is cold, some condensation may appear on the glass. This is normal and the
condensation will disappear as the glass warms.
During this rst re, examine the ame for appearance and quality. Examine the burner media for sooting. The ames should look
like those shown in Figure 33.
After this burn-o period, turn o the Fireplace and let it cool completely to room temperature and clean both sides of the glass
and the interior panels as described in the MAINTENANCE section.
Since it is a metal replace, the heat-up and cool-down cycles may produce some noises caused by the expansion and contraction
of these metals. The premium materials and build quality of your Halcyon Gas Fireplace will keep these sounds to a minimum.
Figure 33- Halcyon Flames
Halcyon Gas Fireplace EuropeanHome.com
38
Page 39
OPERATING the FIREPLACE
G
S
TO TU
CE
LIGHTING AND OPERATING THE HALCYON GAS FIREPLACE
FOR YOUR SAFETY READ BEFORE LIGHTIN
WARNING: If you do not follow these instructions exactly, a re or explosion may
result causing property damage, personal injury or loss of life.
A. This appliance is equipped with an ignition device which automatically lights
the pilot. Do not try to light the pilot by hand.
B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell
next to the oor because some gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
•
Do not touch any electric switch; do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor’s phone. Follow the gas
•
supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
•
C. Do not use this appliance if any part has been under water. Immediately call a
quali ed service technician to inspect the appliance and to replace any part of the
control system and any gas control which has been under water.
LIGHTING INSTRUCTION
STOP! Read the safety information above.
1.
This appliance is equipped with an ignition device which automatically lights
2.
the pilot. Do not try to light the pilot by hand.
Set the Flame Switch to OFF.
3.
Wait ve (5) minutes to clear out any gas then smell for gas including near the
4.
oor. If you smell gas, STOP! Follow “B” in the Safety Information above. If you
don’t smell gas, go to the next step.
Set the Flame Switch to ON. The system will spark to light the pilot ame.
5.
When the pilot ame is lit the main burner will light.
If the pilot ame does not light go to Step 3, above.
6.
RN OFF GAS TO APPLIAN
Set the Flame Switch to OFF to turn o the appliance.
Halcyon Gas Fireplace EuropeanHome.com
39
Page 40
COMPLETING the INSTALLATION
14. FINE-TUNING the FIREPLACE
This section will help you get the best performance from your Halcyon Gas Fireplace.
Note
DO NOT enclose the Halcyon Gas Fireplace until:
• all venting is properly and permanently connected
• the gas supply and electric supply have been tested and are operating properly
• the installation has been inspected and approved by the local code inspection authority
• the Fireplace has been red and ne-tuned
The settings shown on Charts 2 and 3, along with the primary air settings, are the result of extensive testing and are sucient
in nearly every case. However, additional adjustments may be required by certain, specic installation conditions. For example,
an installation on a north wall may require settings which are slightly dierent from those used in a south wall installation. You’ll
know if further ne-tuning is required by looking at the ames in a Fireplace which has been operating for at least an hour.
The ames on your Halcyon Gas Fireplace should be mostly yellow, about four inches long and have some motion to them. They
should be neither short and blue nor long and sooty. If, after operating your Fireplace for at least one hour, the ames look good
then no further adjustment is necessary. See Figure 33.
If an adjustment is necessary it is dependent on the type of fuel that is being used. When burning natural gas, ames that are too
short or too blue will be the most common observation. When burning LP gas, ames that are too long and too sooty will be most
common. Each situation requires dierent actions.
This ne-tuning must be done with the Fireplace installed and operating. As the Fireplace surfaces will be very hot, care must be
taken to avoid serious burns. Always wear gloves and other protective equipment.
SHORT, BLUE and NG
When burning natural gas and the ames are short and blue:
1. If they are open, completely close both primary burner air adjusters.
2. If the appearance of the ame did not change, adjust the air inlet restrictor by:
a) Loosening the intake quadrant locking wingnut
b) Adjust the intake quadrant up the scale by a ¼increment
c) Tighten the wingnut and observe the ames
d) Repeat Step 2 until the ames are taller and more luminescent. If more than one full increment is required and the ames
are still too blue and short then go to Step 3, below.
3. Adjust the exhaust restrictor by:
a) Loosening the exhaust quadrant locking wingnut
b) Adjust the exhaust quadrant up the scale by a ¼increment
c) Tighten the wingnut and observe the ames
d) Repeat Step 3 until the ames are taller and more luminescent. If more than one full increment is required and the ames
are still too short and blue there may be an installation problem. Consult with a European Home representative.
Halcyon Gas Fireplace EuropeanHome.com
40
Page 41
COMPLETING the INSTALLATION
LONG, SOOTY and LP
When burning LP gas and the ames are long and sooty:
1. If the primary burner air adjusters are installed, remove them
2. If the appearance of the ame did not change, adjust the air inlet restrictor by:
a) Loosening the intake quadrant locking wingnut
b) Adjusting the intake quadrant down the scale by a ¼increment
c) Tighten the wingnut and observe the ames
d) Repeat Step 2 until the ame tips become shorter and lighter in color. If more than one full increment is required and the
ames are still too long and sooty then go to Step 3, below.
3. Adjust the exhaust restrictor by:
a) Loosening the exhaust quadrant locking wingnut
b) Adjust the exhaust quadrant down the scale by a ¼increment
c) Tighten the wingnut and observe the ames
d) Repeat Step 3 until the ames are shorter and more luminescent. If more than one full increment is required and the ames
are still too long and sooty there may be an installation problem. Consult with a European Home representative.
Once all adjustments are made, tighten both the Air Intake and Exhaust Outlet Quadrant locking wing nuts. Turn the Fireplace o
and let it cool to room temperature. Close the access doors the before proceeding with the installation.
Halcyon Gas Fireplace EuropeanHome.com
41
Page 42
COMPLETING the INSTALLATION
15. FACING and FINISHING
You’re almost nished!
The Halcyon Gas Fireplace is designed to be enclosed with common building materials; wood, drywall, plaster, etc.
• Any combustible mantels must be installed within the limits described in Section P4 (MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS.)
• Provided the required clearances are maintained, the walls that enclose the side and rear of the Halcyon Gas Fireplace may be
constructed of combustible material. The facing within the limits shown in Figure 13, however, must be made of non-combustible material.
• The Halcyon was designed to be faced with approved ½” thick, non-combustible facing. This non-combustible facing can be
installed up to the Facing Bead which surrounds the opening into which the glass panel is set. Figure 34 shows a close-up view
of the Facing Bead over which no material of any kind may be applied.
• The wall above the Fireplace opening is constantly exposed to elevated temperatures. This must be considered when
choosing any fasteners, paint, mastic, sealant, caulk, etc. for use in this area as materials may change color or emit an odor
when heated. Petroleum-based tile adhesives should be avoided and thin-set mortar used instead.
Halcyon Gas Fireplace EuropeanHome.com
Figure 34- Facing Bead
42
Page 43
MAINTENANCE
Flame
Sensor
Figure 35 - Main Burner
Figure 36 - Pilot Burner
WARNING
Before doing any maintenance work turn o both the gas supply and electric supply then allow the entire Fireplace to cool
completely.
Do NOT clean the glass when it is hot!
To keep your Halcyon Gas Fireplace in peak condition, routine inspection and maintenance should be performed by a qualied
service person. We recommend that this be done prior to the beginning of your heating season.
ANNUAL INSPECTION and CLEANING
1. Remove the glass panel and clean the pilot burner and main burner of any soot, dust or any other build-up. Clean the Flame
Sensor of any corrosion or build-up. Figure 36 shows proper pilot burner operation and Figure 35 shows proper main burner
operation.
2. Inspect the Crushed Glass Burner Media for soot build-up. If excessive soot is present, have a qualied service person inspect
the unit for proper combustion. Carefully clean the Crushed Glass Burner Media with a brush.
3. Check that the vent pipe and termination cap are free from obstructions such as nests, leaves or debris. Ensure that the
venting is tight and sealed.
4. Conrm that the frame, glass and gasket are free from damage including scratches, cracks and misalignment. Check the
latches for proper alignment and engagement. If it is necessary to replace the glass assembly, use only the H50-SA-GP-01
Glass Panel Assembly from European Home.
5. Ensure that the Fireplace is ready for operation, light the Fireplace and check both the pilot burner and main burner for
proper ame size and operation.
Halcyon Gas Fireplace EuropeanHome.com
43
Page 44
MAINTENANCE
PERIODIC CLEANING
NOTE: Both sides of the Halcyon glass panel must be cleaned after the rst re. As part of the ‘burn-o’ process, a white lm may
form on the inside of the glass during the rst few res. Do not allow the lm to accumulate as it can become very dicult to
remove. Allow the glass to cool then clean both sides of the glass panel.
1. The glass may be cleaned as necessary with a replace glass cleaner. We recommend Stove Bright® Gas Appliance Glass
Cleaner by Forrest Paint Co. Follow the instructions for use and do not clean the glass when it is hot! If the glass becomes
coated with deposits which cannot be removed it must be replaced. When replacing the glass panel assembly use only
European Home part number H50-SA-GP-01; substitute parts are not permitted.
2. Exterior metal trim may be cleaned with mild soap and water. Do not use abrasive cleaners on the glass or any other part of
the Fireplace.
3. Interior media components may be cleaned with a clean, soft-bristled brush. Do not use any cleaning products, including water,
on the media.
4. When necessary the panels can be removed and cleaned as follows:
a. The stone-like panels should be brushed with a clean, soft-bristled brush. Do not use any cleaning products, including
water, on these panels.
b. The black enamel panels should be cleaned with a mild, non-abrasive, household cleaner. We recommend Windex® by SC
Johnson & Son, Inc.
c. The stainless steel panels should be cleaned with a stainless steel cleaner. We recommend Stove Bright® Brass and Metal
Polish by Forrest Paint Co.
5. For best results, install the panels while wearing the gloves provided with your Halcyon Gas Fireplace. Do not allow any
liquids to spill inside the Fireplace.
REPLACEMENT PARTS
If replacement parts are required, only parts made specically for your Halcyon Gas Fireplace can be used. Failure to use only parts
specically approved with this appliance may result in property damage or personal injury. Table 10 lists parts approved for use in
the Halcyon Gas Fireplace.
Part NumberDescription
H50-SA-GP-01Glass Panel Assembly
H50-GS-GV-01Gas Valve
H50-GS-CM-01Control Module
H50-ES-LA-01Lamp Assembly
H50-ES-HB-01Halogen Bulb
H50-SA-LPCK-01 LP Conversion Kit
H50-SA-BA-01Burner Assembly
Table 10 - Replacement Parts List
Halcyon Gas Fireplace EuropeanHome.com
44
Page 45
TROUBLESHOOTING
WARNING
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Any repair and troubleshooting of the Halcyon Gas Fireplace must be done by a qualied technician only.
Since the LED on the control module cannot been seen after the Fireplace has been installed, the following assumes that the Halcyon
Burner Assembly has been safely connected to a test bench and that all appropriate safety precautions are being observed.
For proper operation, the control module must be electrically connected to the gas valve and all the ignition wiring connectors
plugged in.
The LED light on the control module provides a self-diagnosis indication. If the red LED is o continuously, the fault is likely to be
internal to the module. To make sure, interrupt the line or 24 volt power for 10 seconds, check program key installation and then
restore. If the internal fault is indicated again, and ame sensor is not shorted to ground, replace the control module. A ashing
light indicates the problem is most likely in the external components or wiring (see Table 11, below). Proceed as follows:
Visual checks
1. After the purge delay (if applicable) the pilot valve opens and the ignition spark starts
2. The pilot burner ame will light
3. The ignition spark stops and the main valve opens
4. The main burner ame will ignite
LEDCondition
Solid ONNormal - Control Module ON
One FlashFalse Flame Signal
Two FlashesNo Flame Detected
Three FlashesSafety Drive Fault
Four FlashesPV Drive Fault
Five FlashesMV Drive Fault
OFFNo Power - Internal Fault
Table 11 - Condition Codes
Halcyon Gas Fireplace EuropeanHome.com
45
Page 46
TROUBLESHOOTING
Contacts close, call for ame
Does the LED stay OFF?
NO
Does it give 1 ash?
NO
Does it give 3 ashes?
NO
Does it give 4 ashes?
YES
YES
YES
YES
CONTROL MODULE TROUBLESHOOTING
Check for low voltage to module (TH-TR).
If no voltage, check limit switches.
If correct voltage is present, module has internal fault - replace it.
Check ame probe and wiring; module is seeing a ame signal with
valve closed.
Check for poor burner ground wiring.
Check for partial shorting on ame probe wiring.
There is a fault in the internal safety relay drive, check that supply
voltage is within spec.
If voltage is within spec., replace control module.
There is an internal fault with the pilot valve (PV) relay.
Check for short between TH and PV.
If no external cause then replace control module.
NO
Does it give 5 ashes?
NO
After pre-purge, does PV
operate and sparks start?
YES
Does it give 2 ashes?
NO
Does the Halcyon run until
turned o?
YES
YES
NO
YES
NO
There is an internal fault with the main valve (MV) relay.
Check for short between TH and MV.
If no external cause then replace control module.
Check wiring to PV if it does not operate, replace PV if voltage present.
Check spark wiring for shorts if no sparks.
Check sparks are at burner, not to outer casing.
Ensure no breaks or cracks in insulation of spark lead.
Ensure pilot ame reaches ame sensor for detection.
Burner has failed to light after permitted attempts.
check pilot ame remains on ame sensor when main burner lights,
check gas jets are clear, check for clean burn.
NORMAL OPERATION
Halcyon Gas Fireplace EuropeanHome.com
46
Page 47
INSTALLATION RECORD
The installer must record the following information about the installation. It is needed for warranty purposes and for any technical
assistance which may be required.
Sold By:__________________________________________________________________________________________________
Fuel: Natural Gas Propane
Inlet Pressure at Installation:_________________________________________________________________________________
Manifold Pressure at Installation :_____________________________________________________________________________
Total Vertical Vent Rise:_____________________________________________________________________________________
Total Horizontal Vent Run:___________________________________________________________________________________
Total Number of 90° Elbows:_________________________________________________________________________________
Total Number of 45° Elbows:_________________________________________________________________________________
Halcyon Gas Fireplace EuropeanHome.com
47
Page 48
NOTES
Halcyon Gas Fireplace EuropeanHome.com
48
Page 49
Appendix A - LP Gas Conversion
These instructions are for use with the European Home H50-SA-LPCK-01 kit only.
WARNING
This conversion kit shall be installed by a qualied service agency in accordance with the manufacturer’s instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is
not followed exactly, a re, explosion or production of carbon monoxide may result causing property damage, personal
injury or loss of life. The qualied service agency is responsible for the proper installation of this kit. The installation is
not proper and complete until the operation of the converted appliance is checked as specied in the manufacturer’s
instructions supplied with the kit.
CAUTION
The gas supply shall be shut o prior to disconnecting the electrical power, before proceeding with the conversion.
Note
When within the Commonwealth of Massachusetts this conversion must be made by a licensed plumber or gastter.
Contents
The H50-SA-LPCK-01 LP Gas Conversion Kit contains the
following:
• Two LP Burner Orices (#56 DMS)
• One Burner Base Gasket (H50-FG-BG-03)
• One LP Conversion Label
• One Instruction Sheet
Installation of the H50-SA-LPCK-01 LP Gas Conversion Kit
requires the following tools:
- an assortment of open end wrenches (⁄” through 1”)
- a No. 2 Phillips screwdriver
- two adjustable wrenches
- ⁄” socket wrench
Tools Required
Halcyon Gas Fireplace EuropeanHome.com
49
Page 50
Appendix A - LP Gas Conversion
LP Gas Conversion Steps
1. Refer to the INSTALLATION section beginning on page 18 and, if they’re in place, remove the Glass Panel Assembly, the
interior panels, the gas supply and burner media.
2. Remove the 21 screws which fasten the burner assembly to the cabinet. Gently lift the burner assembly up about an inch and
move it to the right enough to provide an opening through which you can reach the wiring tunnel. See Figure A1. Take care to
avoid damaging the gasket beneath the burner assembly.
3. Separate the four-conductor plastic connector (the largest of the three connectors) by depressing the latch that holds them
together. See Figure A2.
4. Carefully remove the burner assembly from the cabinet and place it on a clean, sturdy work surface.
Figure A1 - Halcyon Burner Moved To Right Revealing Connections
Latch
Figure A2 - Male Connector Showing Latch
Halcyon Gas Fireplace EuropeanHome.com
50
Page 51
Appendix A - LP Gas Conversion
L. Burner
Figure A3 - Burner Close-up
Burner Tube
L. Burner Tube Air Inlet
L. Burner Orice
Center Tee
5. Remove the left and right burner from the burner assembly by removing the two attaching screws at the center of the burner
assembly and lifting the burners o their supports. See Figure A3.
6. Remove the screw holding each air adjuster to the burner tube, slide each air adjuster o the burner tube, reverse the air
adjusters, slide them back on the burner tube and replace the holding screw on each air adjuster. The air inlet on each burner
tube must not be covered.
Burner Attaching Screws
R. Burner Orice
R. Burner Tube Air Inlet
R. Air Adjuster Screw
R. Burner
R. Air Adjuster
(set for LP use)
7. Remove the left and right natural gas Burner Orices by unscrewing them from the Center Tee. See Figure A3.
8. Screw the left and right LP Burner Orices into the tee and tighten securely.
9. Re-install the left and right Burners and secure them with the Attaching Screws.
10. Loosen the Pilot Burner Nut and push in the Orice Slide to engage the LP Orice. The red dot and “LP” marking on the Slide
will now be exposed and the “NA” marking will be hidden. Tighten the Pilot Burner Nut securely. See Figure A4.
Pilot Burner Nut
Orice Slide
Figure A4 - Pilot Burner Details
Halcyon Gas Fireplace EuropeanHome.com
51
Page 52
Appendix A - LP Gas Conversion
Regulator Cap (LP)
Figure A5 - Gas Valve (LP)
Figure A6 - Close-up of Regulator Cap Set to LP
11. Unscrew the Regulator Cap, turn it over and screw it back in with the recessed end marked “LP” exposed. See Figures A5 and
A6. Figure A7 shows the Regulator Cap before it has been reversed to LP.
12. Write the conversion date and the name and address of the company or person doing the conversion on the LP Conversion
Label. Peel the backing o the label and ax it to the bottom plate of the Burner Assembly, next to the gas valve as shown in
Figure B8.
13. Re-install the Burner Assembly.
14. Test the entire gas train for leaks using a ‘snier’ or non-corrosive leak detection uid.
15. Replace the Glass Panel Assembly.
16. If the Fireplace installation is complete then test for proper pressures, ame pattern and operation otherwise return to the
appropriate section of the Installation, Operation and Owner’s Manual and complete the installation.
Retain the removed parts if the Halcyon Gas Fireplace is to be re-converted for use with natural gas.
Figure A7 - Close-up of Regulator Cap Set to “NAT”
Halcyon Gas Fireplace EuropeanHome.com
52
Page 53
Appendix A - LP Gas Conversion
This appliance was converted on / / to LP gas with kit no. H50-SA-LPCK-01 by
name
addr
which accepts the responsibility that this conversion has been properly made.
Figure A8 - LP Conversion Label Axed to Burner Assembly
After conversion to use with LP gas, the Halcyon Gas Fireplace has the following specications:
Propane (LP)
Input: 32,000 BTU/hr. (9.37 kWh)
Manifold Pressure: 9.2” w.c. (2.29 kPa)
Maximum Supply Pressure: 13” w.c. (3.23 kPa)
Minimum Supply Pressure: 11” w.c. (2.73 kPa)
Orice Size: #56 DMS
OMNI-Test Laboratories, Inc. has certied that the Halcyon Gas Fireplace meets the ANSI Z21.88-2007 • CSA 2.33-2007 Vented Gas Fireplace Heaters and CAN/CGA-2.17-M91, Gas-Fired Appliances for Use At High Altitudes standards.
The Halcyon Gas Fireplace is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500 feet)
in Canada without change. If your installation is at an elevation greater than these, consult with the local authority having
jurisdiction for gas product installations to determine their specic requirements for high altitude installations.
When properly installed and operating the ames in the Halcyon Gas Fireplace look like those in Figure A9.
Halcyon Gas Fireplace EuropeanHome.com
Figure A9- Halcyon Flames
53
Page 54
EUROPEAN HOME
a division of Europa Ja, Inc.
376 Washington Street
Suite 203
Malden, MA 02148-1300
tel: 781.324.8383
fax: 781.324.8384
info@europeanhome.com
HalcyonGas Fireplace EuropeanHome.com
54
rev.110707u