Halco 88987, 88985, 88986, 88984 Installation Manual

Page 1
ProLED Select® Field Selectable CCT+Wattage
Commercial Downlight Retrofit
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. To reduce the risk of elec trica l shock, turn off power supply before install ation o r servicing.
2. This lumi naire m ust be installed in accor dance w ith the NEC or your local ele ctric al code. If you are not famil iar wit h these codes and require ments , consult a qualified elec trici an.
3. Risk of fire or electri c shock . Install this kit only in th e luminaires that have the constru ction features and dime nsion s shown in the photogr aphs an d/or drawings.
4. To preve nt wiring damage or abras ion, do n ot expose wiring t o edges of sheet metal or ot her sharp objects.
5. The re cessed luminaire is int ended f or mounting only i n a cover ed
ceiling w here on ly the led side of the lumina ire wil l be exposed to dry , damp or wet loca tions.
RETROFIT INSTALLATION
STEP 1:
Make sure t he POWE R IS TURNED OFF at t he source to t he rece ssed housing in which you a re install ing the p roduct.
3
1
4
STEP 2(Fig 1) :
If existi ng lamp a nd trim are present, remo ve from ceiling o r move it o ut of the way as it will not be needed du ring in stallation. Measure t he ceil ing opening t o make su re the edge of the luminair e will cove r the ent ire hole and still sit firml y in the ceiling b efore p roceeding.
2
STEP 3 :(Fig2)
Attach th e carab iner safety clip to the exi sting fixture ho using .
STEP :4 (Fig3/Fig7)
Remove junction box faceplate. Disconnect all wires to the ballast and remove ballast from J-Box. Remove appropriate round knock out and attach the fixture conduit whip into knock out. Connect incoming power (White to White, Black to Black, Green to Green/Ground). For 0-10V dimming circuits, connect Gray to Gray and Purple to Purple. Reattach J-Box faceplate.
STEP (Fig 4):5
Adjust th e fixtur e power to desired lumen ou tput by sliding t he sele ctor switch. Adjus t the color tempera ture to d esired one, by sliding th e other selecto r switc h. Make sure the switch is ne ver in between p ositi ons.
LINE
COMMON
GROUND
DIM+
DIM-
5
BLACK
WHITE
GREEN
PURPLE
GRAY
Page 1 of 2
6
STEP (Fig 5):6
Squeeze t he two sp ring clips so they are in an upright p ositi on and insert lamp into hou sing.
STEP (Fig 6):7
Once fixtu re is ins ide the housing, releas e the spring cl ips and c ontinue pushing fixtur e until securel y fixed an d flush with ceiling.
7
STEP :8
Restore p ower at t he source and the install ation is comple te.
Page 2
Model A B C
5.9" 150mm 8.2"(209mm) 4.0"(101mm)
7.3"(186mm) 10.2"(260mm) 4.4"(112mm)
ProLED Select® Field Selectable CCT+Wattage Commercial Downlight Retrofit
NEW CONSTRUCTION INSTALLATION
NCPLATE
STEP 1:
Make sure t he POWE R IS TURNED OFF at t he source to t he rece ssed housing in which you a re install ing the p roduct.
STEP 2(Fig 1) :
If using a ne w Const ruction Plate, instal l it in the ceiling f ollow ing its own installatio n instr uction.
NCPLATE/T
LINE
COMMON
GROUND
DIM+
DIM-
3
5
1
BLACK
WHITE
GREEN
PURPLE
GRAY
4
6
STEP 3 :(Fig2)
If a new hole i s neede d, use a hole cutter, and set
2
the diame ter to 6- 5/32” (156mm) for the D84 6, 8” (203mm ) for the D 848 or cut along the edge of the new con struc tion plate prepared for t he desi red size .
STEP :4 (Fig3/Fig7)
Attach the carabiner safety clip to a secure place inside the ceiling. Insert lamp conduit into a preinstalled J-box (not provided) and wire to the power source (black to hot, white to neutral, green to ground). For 0-10V dimming circuits, connect gray to gray and purple to purple. Close the J-box securely
STEP (Fig 4):5
Adjust th e fixtur e power to desired lumen ou tput by sliding t he sele ctor switch. Adjus t the color tempera ture to d esired one, by sliding th e other selecto r switc h. Make sure the switch is ne ver in between p ositi ons.
STEP (Fig 5):6
Squeeze t he two sp ring clips so they are in an upright p ositi on and insert lamp into hou sing.
STEP (Fig 6):7
Once fixtu re is ins ide the housing, releas e the spring cl ips and c ontinue pushing fixtur e until securel y fixed an d flush with ceiling.
STEP :8
Restore p ower at t he source and the install ation is comple te.
7
COMMERCIAL DOWNLIGHT HOUSING COMPATIBILITY
C
·6" is compatible with most standard housing with aperture ranging from
A B
Halco Lighting Technologies 2940 Pacific Drive, Norcross, GA 30071 Toll Free 800.677.3334 | Fax 800.880.0822 halcolighting.com
6"-7.5" (153-190mm).
·8" is compatible with most standard housing with aperture ranging from
7.6"-9.5" (195-240mm).
6" 8"
Page 2 of 2
Loading...