HA309 thermostat is luxurious in appearance with a large LCD display screen special for electrical heating. It is available for room temperature control in residential, industrial and business premises, controlling the on/off of the electrical heating equipment, to achieve comfort and energy saving purposes. HA309, the thermostat shows indoor temperature, floor temperature, setting temperature, thermostat output state, and time through the use of micro-computer control technology with big LCD display screen. HA309’s buttons include:
Power
, Mode, Time, Temperature Regulator(Up/Down)Backlit,
Program,Reset, with sensor alarm light (Alarm).
BASIC FEATURES STATUS DISPLAY
Room temperature setting and measurement Floor temperature setting and measurement Manual/Timer/4 periods programmable 4 periods programmable mode:5+2/6+1/7days Celsius /Fahrenheit, 24/12 hours Room highest/lowest temperature range setting
Floor highest/lowest temperature range setting
Relay Pick-up Times inquiry Restoring factory settings Sensor fault alarm Difference adjustable function Sensor for room only/floor only/both room and floor Low-temperature protection Auto Recovery Green backlight
Room temperature display
Room setting temperature display
Floor temperature display
Floor setting temperature display
Degrees Celsius shows
Fahrenheit shows
Thermostat output states
Thermostat output delay display
Preheat output displayed in advance
Time display
Week display
4 periods display
SPECIFICATIONS
Sensing element: NTC
Set-point range: (could set upper/lower limit)
Inside sensor:5-35 [41-95] Outside sensor:5-45[41-113] Only outside sensor:0-90[32-194]
Operating temperature: 0-45 [32-113]
Operating humidity: 5-95%RH ( non-condensing )
Button: Silicone Rubber Keypad
Power supply: AC85-250V50/60Hz
Power consumption: <3W
Wirings: Wiring 0.0016x0.0062sq. in.( 1×4 mm2 wires)
Switch current rating: 16 A(Resistive)
Housing: PCABS Flame Retardant
Dimensions:2.95x4.82x1.04”
(75×122.5×26.5mm) (W×H×D)
Hole pitch: 3.29” (83.5 mm)(standard)
Protection class:IP30
OPERATION
On/Off: Press “POWER” to turn on, press “POWER” again to turn off, and off the electric heating equipment at the same time. Setting temperature: When power is on, press “Down” to reduce set-point, press “Up” to raise set-point. (0.5[1] changed each press.) Electric heating equipment’s control: When the room temperature is 1 (when the offset is 2) lower than the setting temperature, the thermostat will put through the power of the
electric heating equipment, and the LCD will display “ ”; When the room temperature is 1 (when the offset is 2) higher than the setting temperature, the thermostat will close the power of the electric heating equipment, and “ ” will disappear.
If open the ”output delay” function, (refer to No.15 and No.16 of the parameter list): “ ” flashing means delaying, and the thermostat will output. When the delay time shows, the LCD
shows “ ”, the thermostat output, and put through the power of the electric heating equipment.
MANUAL MODE、TIMER ON/OFF FUNCTION MODE AND 4 PERIODS MODE CHOICES
Timer on: Press “Mode” for 3 seconds, LCD shows “XX”, press “Up” or “Down” to adjust the parameter. “01” stands for manual mode, that means after set the temperature, and no change, LCD shows “ ”. “02” stands for timer on/off mode, LCD shows “ ”. “03” stands for 4 periods mode, LCD shows corresponding time symbol. 4 PERIODS’ CORRESPONDING SYMBOLS:
Period 1 Period 2 Period 3 Period 4
Wake Leave Return Sleep
TIMER AND TIMER ON/OFF FUNCTION SETTING
Time adjust: press “Time”, till to display “hh:mm” and “hh” flashes,press “Up” or “Down” to adjust hour; press “Time”, “mm” flashes, press “Up” or “Down” to adjust minute; press “Time”,
then week flashes, press “Up” or “Down” to adjust week.
Timer on: Press “Time”, till to display “TIMER ON” and “hh” flashespress “Up” or “Down” to adjust time on hour, press “Time”, “mm” flashes, press “Up” or “Down” to adjust the time
on minute; Press “Time”, till “TIMER OFF” and “hh” flashes. Use the above method, setting the time on/off hour and minute, the time on/off will be valid until to be canceled.
Canceling timer on: Method 1: Setting the time on/off hour and minute as “00”; Method 2: As per the tip of the “manual mode, timer on/off function mode and 4 periods mode choices”,
switch the mode to manual “01” or 4 periods “03”.
4 EVENTS PROGRAMMING SETTING
Dividing a week into seven separate days or 5+2/6+1(Monday….Friday + Sat Sun/ Mon….Sat + Sun), each day has four periods with different setting temperature to meet with
customer’s individual demand.
Temperature unit default is Fahrenheit, if need to change into Degrees Celsius, please refer to “parameter setting datasheet”. Taking Working days (Mon-Fri), Resting days (Sat-Sun) 4 periods setting as an example, reference as below: Working day setting : period 1 setting : press “Prog” ,and LCD shows “ ” and “Mon Tue Wed Thu Fri”, “hh” flashes in “hh:mm”, and then press “Up” or “Down” to set hours; press
“Prog”, “mm” flashes in “hh:mm”, and then press “Up” or “Down” to set minutes; press “Prog”, temperature flashes, and then press “Up” or “Down” to set the temperature, and the other time period is set by the same way.
Resting day setting: Press “Prog” till to show “ ” and “Sat Sun” and then set as the above method. Please separate each time period when set the above time period, so as to avoid the system work fault. This thermostat has installed following initial values:
5+2
Working days/Resting
days
Period 1 Period 2 Period 3 Period 4
Starting T / temp. Starting T / temp. Starting T / temp. Starting T / temp.
Working days(Mon-Fri
7:00 20 [68] 8:30 16 [61] 17:00 22 [72] 21:30 18 [64]
Resting days(Sat-Sun
7:30 21 [70] 9:00 20 [68] 17:30 22 [72] 22:00 18 [64]
Cancelling Working days /Resting days 4 periods function, please as per the tip of the “manual mode, timer on/off function mode and 4 periods mode choices” , switch the mode to
manual ”01” or timer on/off “02”.
Taking Working days, Resting day 4 periods setting as an example, this thermostat has installed following initial values:
6+1
Working days/Resting
days
Period 1 Period 2 Period 3 Period 4
Starting T / temp. Starting T / temp. Starting T / temp. Starting T / temp.
Working days(Mon- Sat
7:00 20 [68] 8:30 16 [61] 17:00 22 [72] 21:30 18 [64]
Resting day(Sun) 7:30 21 [70] 9:00 20 [68] 17:30 22 [72] 22:00 18 [64]
Take each day’s 4 periods of a week (7days) as an example, reference as below:
7 days 4 periods programmable: Separate each day into 4 periods, each period includes the start time and the programmable temperature. Before follow below steps to program the 7days, please layout the starting time and temperature. Press “Prog”, LCD shows “ ” and “Mon”, as per the initial value datasheet and follow steps to set the 4 periods program of Mon. “hh” flashes in “hh:mm”, press “Up”, “Down” to set the
hour of the program. Press “Prog”, “mm” flashes in “hh:mm”, press “Up” or “Down” to set the minute of the program. Press “Prog”, program temperature flashes, press “Up”, “Down” to set the program temperature.
1. Press “Prog”, “hh” flashes in “hh:mm”, press “Up”, “Down” to set the hour of the second period program.
2. Press “Prog”, “mm” flashes in “hh:mm”, press “Up”, “Down” to set the minute of the second period program.
3. Press “Prog”, program temperature flashes, press “Up” or “Down” to set the adjustable temperature.
4. Repeat 1-3 steps to set the 3-4 periods of Mon.
5. Press “Prog”, show “ ” and “Tue”. Repeat 1-4 steps to set the 1-4 periods of Tue.
6. Repeat 1-5 steps to set Wed, Thu, Fri, Sat, Sun. This thermostat has installed following initial values:
Week
Period 1 Period 2 Period 3 Period 4
Starting T / temp. Starting T / temp. Starting T / temp. Starting T / temp.
Mon 7:00 20 [68] 8:30 16 [61] 17:00 22 [72] 21:30 18 [64]
Tue 7:00 20 [68] 8:30 16 [61] 17:00 22 [72] 21:30 18 [64]
Wed 7:00 20 [68] 8:30 16 [61] 17:00 22 [72] 21:30 18 [64]
Thu 7:00 20 [68] 8:30 16 [61] 17:00 22 [72] 21:30 18 [64]
Fri 7:00 20 [68] 8:30 16 [61] 17:00 22 [72] 21:30 18 [64]
Sat 7:30 21 [70] 9:00 20 [68] 17:30 22 [72] 22:00 18 [64]
Sun 7:30 21 [70] 9:00 20 [68] 17:30 22 [72] 22:00 18 [64]
PARAMETER SETTING LIST
Power off, press “mode” and “time” button at the same time and hold for 6 seconds, enter the parameter setting interface. Now press “clock” button to page down and “mode” button to
page up selecting parameter, and press “up” and “down” button to adjust the parameter value.
NO. Parameter Setting Description Default Value Range
01 CC Thermostat working time counter 0-1999 Days
02 Pr
4 periods mode choices: 52=5+2 4 periods;61=6+1 4 periods;74=7 4 periods; no=have no 4 periods, it is manual or time on/off mode.
no
5+2 4 periods 6+1 4 periods
7days 4 periods
03 rH Setting the highest room temperature range 35 95 10-45 50-113
04 rL Setting the lowest room temperature range 5 41 3-9 37-48 05 FH Setting the highest floor temperature range 45 113 20-60 68-140 06 FL Setting the lowest floor temperature range 5 41 5-10 41-50 07 CF Celsius /Fahrenheit, 24/12 hours :12,24,12,24 24
08 Fr Low temperature protecting function on/off: 0=off;1=on 0 0-1 09 dB Difference setting 2/ 1-9/ 10 5E Sensor mode: 0=only inside; 1=only outside;2=both inside and outside.
0 0-2
11 rC Room temperature adjustment 0/ -9-9/ 12 FC Floor temperature adjustment 0/ -9-9/
13 BC Compensation factor adjustment 47 30-99 14 dd Auto recovery: 0=auto recovery;1=no auto recovery;2=power on 0 0-2
15 rE
When power re-supplied, relay time adjustable. Default =0, relay time is 10 seconds
0 min 0-15min
16 DE Temperature-variation caused relay off-on process time set 0 min 0-15min 17 O5 Auto-adjustable function on and off 0=off, 1=on 0 0-1 18 OP Preheat output displayed in advance setting 3h 0-3h 19 CO Set preheat output value 20min 10min 10-120min 5-60min 20 Oh Set only outside sensor‘s highest temperature 90 194 30-90 85-194 21 OL Set only outside sensor‘s lowest temperature 0 32 0-10 32-50
NOTE:
(*) Only Auto-adjustable function on, parameter shows No.18, No.19.
(**) Only choose single outside sensor, parameter shows No. 20, No.21.
FLOOR TEMPERATURE EXAMINATION AND SETTING
Check the floor temperature: power on status, press “Mode” one time, LCD shows “ ”, “XX.X” or “XX” shows the floor temperature. Single sensor setting is without this function.
Set the floor temperature: power off status: press “Mode” for 7 seconds, until LCD shows “SET XX.X” or “SET XX”, then press “Up” or “Down” to set the floor protection
temperature. Default Setting is 35[95].
LOW TEMPERATURE PROTECTION
When the low temperature protection is valid, thermostat turns off and the room temperature (or floor temperature) is lower than 5 [41], the thermostat will auto start heating and
show “ ”, turn on the electric heating equipment, when the room temperature (or floor temperature) increases to 7 [45], the thermostat will end output auto.
The on /off of the low temperature protection function, please refer to the “Parameter Setting Table”.
WIRING DIAGRAM
Note:
1. Wire all circuits as Class 1, Electric Light or Power Circuits, including the Sensor input.
2. The length of the outside sensor cannot be longer than 45.72 ft. (15m). The sensor needs to be housed in a suitable plastic enclosure and the sensor leads voltage have to be rated
not less than the maximum rated line voltage of the device.
3. Only one sensor style: If only inside sensor’s fault, LCD shows “E0”; If only outside sensor’s fault, LCD shows “E1”. Both inside and outside sensor: inside sensor fault, LCD shows ”E0”, outside sensor fault, LCD shows “E2”. If any above fault happened, alarm will flash, and the thermostat will turn off the output
.
INSTALLATION
The device should be installed in place at least 32.81 ft. (10 meters) from the electrical service panel.
Note: Connect all wires as per the wiring diagrams and keep it away from water, mud and other materials.
1. Fix the mounting plate with the screws.
2. Wire according to the wiring program.
3. Push the button to install the product into the mounting plate.
4. Lock the screw.